Experimental evidence of matrix effects in total-reflection X-ray fluorescence analysis: Coke case

被引:25
作者
von Bohlen, Alex [1 ]
Fernandez-Ruiz, Ramon [2 ]
机构
[1] Leibniz Inst Analyt Wissensch ISAS, Bunsen Kirchhoff Str 11, D-44139 Dortmund, Germany
[2] Univ Autonoma Madrid, Serv Interdept Invest SIdI, Lab TXRF, E-28049 Madrid, Spain
关键词
Total reflection X-Ray fluorescence; TXRF; Matrix effects; Absorption; Coke; Beverages; Direct analysis;
D O I
10.1016/j.talanta.2019.120562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Total-reflection X-ray Fluorescence (TXRF) analysis is an established method used in instrumental analytical chemistry. Benefits and drawbacks of the method are well known. They have been described in the past and presented in many papers in the last decades. One of the most impressive features, not common to other X-ray fluorescence methods, is the absence of matrix effects and therefore the use of a simple and reliable quantification. Nevertheless, in some cases, TXRF suffers from matrix effects if the sample amount exceeds the condition of a transparent film-like sample or simply if the system is overloaded. In this work, we present the results of TXRF analysis of the different components of beverages summarized under the generic name 'Coke'. Some of them contain up to 10% of sugars and others only mg-amounts of sweeteners. Different sample pre-treatments were applied in order to get reliable results of trace element contents in Coke. A significant deviation of the concentration of elements detected by their characteristic X-ray radiation between 1 and 5 keV (e.g. for P, S, K and Ca) was observed depending on the sample amounts and sample preparation. This behaviour could only be explained by the presence of matrix effects. Transmission curves depending on the residual film-like sample after drying the beverages were calculated and compared with measurements. The obtained deviations for the different sample preparations and different amounts presented to the spectrometer are in good agreement with the theory. TXRF results obtained after microwave digestion for traditional and light Coke were validated by ICP-MS analyses.
引用
收藏
页数:6
相关论文
共 15 条
[1]  
[Anonymous], [No title captured]
[2]   Comprehensive approach to the validation of the standard method for total reflection X-ray fluorescence analysis of water [J].
Borgese, Laura ;
Dalipi, Rogerta ;
Riboldi, Alessandro ;
Bilo, Fabjola ;
Zacco, Annalisa ;
Federici, Stefania ;
Bettinelli, Maurizio ;
Bontempi, Elza ;
Depero, Laura Eleonora .
TALANTA, 2018, 181 :165-171
[3]  
Born M., 1980, Principles of optics, V6, P36
[4]   The total reflexion of X-rays [J].
Compton, AH .
PHILOSOPHICAL MAGAZINE, 1923, 45 (270) :1121-1131
[5]   Uncertainty in the Multielemental Quantification by Total-Reflection X-ray Fluorescence: Theoretical and Empirical Approximation [J].
Fernandez-Ruiz, R. .
ANALYTICAL CHEMISTRY, 2008, 80 (22) :8372-8381
[6]   Three empirical cases of the deposition morphology influence in the analytical quality of direct solid suspension measurements by total-reflection X-ray fluorescence [J].
Fernandez-Ruiz, R. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) :672-678
[7]   Analysis of coke beverages by total-reflection X-ray fluorescence [J].
Fernandez-Ruiz, Ramon ;
von Bohlen, Alex ;
Friedrich K, E. Josue ;
Redrejo, M. J. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 145 :99-106
[8]   Saturation effects in TXRF on micro-droplet residue samples [J].
Hellin, D ;
Fyen, W ;
Rip, J ;
Delande, T ;
Mertens, PW ;
De Gendt, S ;
Vinckier, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) :1517-1523
[9]   Investigation of element distribution and homogeneity of TXRF samples using SR-micro-XRF to validate the use of an internal standard and improve external standard quantification [J].
Horntrich, C. ;
Smolek, S. ;
Maderitsch, A. ;
Simon, R. ;
Kregsamer, P. ;
Streli, C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (08) :2649-2654
[10]  
Klockenkämper R, 2015, CHEM ANAL SERIES MON, V181