Performance by Design: Supporting Decisions around Indoor Air Quality in Offices

被引:9
|
作者
Snow, Stephen [1 ]
Oakley, Michael [1 ]
Schraefel, M. C. [1 ]
机构
[1] Univ Southampton, Southampton, Hants, England
来源
PROCEEDINGS OF THE 2019 ACM DESIGNING INTERACTIVE SYSTEMS CONFERENCE (DIS 2019) | 2019年
基金
英国工程与自然科学研究理事会;
关键词
Indoor air quality; CO2; Human-Building Interaction; office; awareness; situated display; design; comfort; POSTOCCUPANCY EVALUATION; VENTILATION RATE; FEEDBACK; CO2; SYMPTOMS; BEHAVIOR; ENERGY;
D O I
10.1145/3322276.3322372
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Poor indoor air quality (IAQ) can affect health and cognitive performance prior to users becoming aware of the declining air quality. Yet office occupants rarely have access to IAQ information upon which to base their ventilation decisions. This paper details the design and deployment of a situated IAQ display as a probe to explore ventilation and building operation practices when IAQ information is made available. Based on deployments in 11 naturally ventilated offices, we present an analysis of how reflection and sense making around IAQ can inform interactions with buildings. We suggest displays that are locally situated, non-disruptive and visualise the effects of poor IAQ with human analogies may hold potential for engaging office occupants with IAQ. We highlight how ambient displays represent a stepping-stone towards more informed interactions which can improve air quality and cognitive performance, and how IAQ feedback may usefully contribute to alternative HCI research agendas such as Human-Building Interaction.
引用
收藏
页码:99 / 111
页数:13
相关论文
共 50 条
  • [41] Evidence-driven indoor air quality improvement: An innovative and interdisciplinary approach to improving indoor air quality
    Lovric, Mario
    Gajski, Goran
    Fernandez-Aguera, Jessica
    Pohlker, Mira
    Gursch, Heimo
    Borg, Alex
    Switters, Jon
    Mureddu, Francesco
    BIOFACTORS, 2025, 51 (01)
  • [42] Coupled heat and mass transfer analysis for indoor air quality and thermal comfort in naturally ventilated offices
    Huang, Zhaopeng
    Li, Qiong
    He, Yiyuan
    Ding, Xiang
    Dong, Yunli
    Gao, Wenfeng
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [43] Pollution levels and characteristics of phthalate esters in indoor air of offices
    Min Song
    Chenchen Chi
    Min Guo
    Xueqing Wang
    Lingxiao Cheng
    Xueyou Shen
    Journal of Environmental Sciences, 2015, (02) : 157 - 162
  • [44] Pollution levels and characteristics of phthalate esters in indoor air of offices
    Song, Min
    Chi, Chenchen
    Guo, Min
    Wang, Xueqing
    Cheng, Lingxiao
    Shen, Xueyou
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2015, 28 : 157 - 162
  • [45] Efficiency assessment of indoor environmental policy for air-conditioned offices in Hong Kong
    Wong, L. T.
    Mui, K. W.
    APPLIED ENERGY, 2009, 86 (10) : 1933 - 1938
  • [46] Influence of indoor air quality on energy performance of HVAC systems
    Kajtar, Laszlo
    Hrustinszky, Tamas
    PROCEEDINGS OF THE 6TH IASME/WSEAS INTERNATIONAL CONFERENCE ON HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT (HTE'08), PTS I AND II: NEW ASPECTS OF HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT, 2008, : 360 - +
  • [47] Assessment of Indoor Air Quality Performance in a Building at Kemaman, Terengganu
    Razali, Mohd Azahari
    Semang, Stewart Sumping
    Sani, Winardi
    Taweekun, Juntakan
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2024, 16 (02): : 227 - 236
  • [48] A genetic algorithm based framework to model the relationship between building renovation decisions and occupants' satisfaction with indoor environmental quality
    Awada, Mohamad
    Srour, Issam
    BUILDING AND ENVIRONMENT, 2018, 146 : 247 - 257
  • [49] Indoor air quality - a key element of the energy performance of the buildings
    Vasile, V.
    Petran, H.
    Dima, A.
    Petcu, C.
    Sustainable Built Environment Tallinn and Helsinki Conference SBE16 Build Green and Renovate Deep, 2016, 96 : 277 - 284
  • [50] Numerical evaluation of wind driven ventilator for enhanced indoor air quality
    Lien, Jason
    Ahmed, Noor
    INTERNATIONAL ENERGY CONGRESS 2012, 2012, 49 : 124 - 134