Detection of Cd2+ in Aqueous Solution by the Fluorescent Probe of CdSe/CdS QDs Based on OFF-ON Mode

被引:13
|
作者
Wang, Dengpeng [1 ,2 ]
Gao, Feng [1 ,2 ]
Wang, Xianran [1 ,2 ]
Ning, Xiaomei [1 ,2 ]
Wang, Kaituo [1 ,2 ]
Wang, Xinpeng [1 ,2 ]
Wei, Yuezhou [3 ]
Fujita, Toyohisa [1 ,2 ]
机构
[1] Guangxi Univ, Guangxi Key Lab Proc Nonferrous Met & Featured Ma, MOE Key Lab New Proc Technol Nonferrous Met & Mat, Nanning 530004, Peoples R China
[2] Guangxi Univ, Sch Resources Environm & Mat, Nanning 530004, Peoples R China
[3] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Peoples R China
基金
中国国家自然科学基金;
关键词
QDs; fluorescence quenching; fluorescence restore; Cd2+ detection; adsorption; desorption; QUANTUM DOTS; TRACE CADMIUM; IONS; SAMPLES; METALS;
D O I
10.3390/toxics10070367
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The detection of heavy metals in aqueous solutions has always attracted much attention from all over the world. A fluorescent probe of CdSe/CdS core-shell quantum dots (QDs) was designed to detect trace Cd2+ in aqueous solutions using the OFF-ON mode rapidly and efficiently, likely based on adsorption and desorption reactions between ethylenediaminetetraacetic acid disodium salt (EDTA) and CdSe/CdS QDs. In the OFF mode, the optical shielding function of EDTA results in fluorescence quenching owing to the strong adsorption ability of EDTA with Cd2+ on the sites of CdSe/CdS QDs surface. In the ON mode, the introduction of Cd2+ promotes the desorption of EDTA from the EDTA-CdSe/CdS QDs and restores the fluorescence intensity. There were two linear response ranges which were 0.1-20 mu mol/L and 20-90 mu mol/L for the EDTA-CdSe/CdS system to detect Cd2+. The detection limit was 6 nmol/L, and the standard deviation was below 4% for the detection of Cd2+ concentration in tap water.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Carbon dots as fluorescent probes for "off-on" detection of Cu2+ and L-cysteine in aqueous solution
    Zong, Jie
    Yang, Xiaoling
    Trinchi, Adrian
    Hardin, Simon
    Cole, Ivan
    Zhu, Yihua
    Li, Chunzhong
    Muster, Tim
    Wei, Gang
    BIOSENSORS & BIOELECTRONICS, 2014, 51 : 330 - 335
  • [22] An "off-on-off" fluorescent probe for the sequential detection of Zn2+ and hydrogen sulfide in aqueous solution
    Dong, Zhengping
    Le, Xuanduong
    Zhou, Panpan
    Dong, Chunxu
    Ma, Jiantai
    NEW JOURNAL OF CHEMISTRY, 2014, 38 (04) : 1802 - 1808
  • [23] A quantum dot-based "off-on" fluorescent probe for biological detection of zinc ions
    Xu, Hu
    Wang, Zhiping
    Li, Yan
    Ma, Shijian
    Hu, Peiyi
    Zhong, Xinhua
    ANALYST, 2013, 138 (07) : 2181 - 2191
  • [24] A new "off-on" fluorescent probe for Pd2+ in aqueous solution and live-cell based on spirolactam ring-opening reaction
    Huang, Qi
    Zhou, Yanmei
    Zhang, Qingyou
    Wang, Enze
    Min, Yinghao
    Qiao, Han
    Zhang, Junli
    Ma, Tongsen
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 22 - 29
  • [25] A new acridine derivative as a highly selective 'off-on' fluorescence chemosensor for Cd2+ in aqueous media
    Wang, Yu
    Hu, XueYan
    Wang, Lei
    Shang, ZhuoBin
    Chao, JianBin
    Jin, WeiJun
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (01) : 126 - 131
  • [26] A Selective, Nontoxic, OFF-ON Fluorescent Molecular Sensor Based on 8-Hydroxyquinoline for Probing Cd2+ in Living Cells
    Mameli, Marta
    Aragoni, M. Carla
    Arca, Massimiliano
    Caltagirone, Claudia
    Demartin, Francesco
    Farruggia, Giovanna
    De Filippo, Greta
    Devillanova, Francesco A.
    Garau, Alessandra
    Isaia, Francesco
    Lippolis, Vito
    Murgia, Sergio
    Prodi, Luca
    Pintus, Anna
    Zaccheroni, Nelsi
    CHEMISTRY-A EUROPEAN JOURNAL, 2010, 16 (03) : 919 - 930
  • [27] A retrievable and highly selective peptide-based fluorescent probe for detection of Cd2+ and Cys in aqueous solutions and live cells
    Wang, Peng
    Duan, Liping
    Liao, Yunwen
    MICROCHEMICAL JOURNAL, 2019, 146 : 818 - 827
  • [28] An 2-(2′-aminophenyl)benzoxazole-based OFF-ON fluorescent chemosensor for Zn2+ in aqueous solution
    Chen, Maliang
    Lv, Xin
    Liu, Yunlong
    Zhao, Yun
    Liu, Jing
    Wang, Pi
    Guo, Wei
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2011, 9 (07) : 2345 - 2349
  • [29] A selective fluorescent probe for the detection of Cd2+ in different buffer solutions and water
    Xu, Zheng
    Li, Guoqiang
    Ren, Yuan-Yuan
    Huang, Hua
    Wen, Xiaoping
    Xu, Qiang
    Fan, Xiaotian
    Huang, Zhao
    Huang, Junhai
    Xu, Lin
    DALTON TRANSACTIONS, 2016, 45 (30) : 12087 - 12093
  • [30] A new highly selective fluorescent sensor for detection of Cd2+ and Hg2+ based on two different approaches in aqueous solution
    Jiang, Xiu-Juan
    Fu, Yan
    Tang, Hao
    Zang, Shuang-Quan
    Hou, Hong-Wei
    Mak, Thomas C. W.
    Zhang, Hong-Yan
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 844 - 850