Ultrapure dialysate reduces plasma levels of β2-microglobulin and pentosidine in hemodialysis patients

被引:50
作者
Furuya, R
Kumagai, H
Takahashi, M
Sano, K
Hishida, A
机构
[1] Iwata City Hosp, Dept Internal Med, Div Renal, Iwata 4388550, Japan
[2] Univ Shizuoka, Sch Food & Nutr Sci, Dept Clin Nutr, Shizuoka, Japan
[3] Hamamatsu Univ Sch Med, Dept Orthoped Surg, Hamamatsu, Shizuoka 43131, Japan
[4] Hamamatsu Univ Sch Med, Dept Med 1, Hamamatsu, Shizuoka 43131, Japan
关键词
dialysate purity; beta(2)-microglobulin; chronic inflammation; pentosidine;
D O I
10.1159/000086554
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: beta(2)-Microglobulin (beta(2)MG) and carbonyl stress are reported to contribute to the development of dialysis-related amyloidosis. The aim of this study was to determine whether the purity of dialysate affects plasma levels of beta(2)MG and pentosidine ( a surrogate marker of carbonyl stress) in hemodialysis patients. Methods: Sixteen patients on hemodialysis with a polysulfone membrane participated in this study. We switched the dialysate from conventional dialysate ( endotoxin level 0.055 - 0.066 endotoxin units (EU)/ml) to ultrapure dialysate (endotoxin level < 0.001 EU/ml), followed patients for 6 months, and then switched back to conventional dialysate once again. Plasma levels of beta(2)MG, pentosidine, CRP and interleukin-6 (IL-6) were determined before the switch to ultrapure dialysate, 1 and 6 months after the switch to ultrapure dialysate, and 1 month after the switch back to conventional dialysate. Results: The switch from conventional to ultrapure dialysate significantly decreased plasma levels of beta(2)MG, from 30.1 +/- 1.4 to 27.1 +/- 1.4 mg/dl (p < 0.05) and pentosidine, from 1,535.8 +/- 107.5 to 1,267.6 +/- 102.9 nmol/l (p < 0.01) after 1 month of use. The change of dialysate also significantly decreased plasma levels of CRP, from 0.28 +/- 0.09 to 0.14 +/- 0.05 mg/ dl ( p < 0.05) and IL-6, from 9.4 +/- 2.7 to 3.5 +/- 0.8 pg/ml ( p < 0.01) over the 1-month period. These changes in plasma levels of beta(2)MG, pentosidine, CRP and IL-6 were maintained over 6 months after switching to ultrapure dialysate and returned to basal levels by switching back to a conventional dialysate. Conclusions: Ultrapure dialysate decreases plasma levels of beta(2)MG, pentosidine and inflammatory markers in hemodialysis patients. The use of ultrapure dialysate might be useful in preventing and/or treating complications of dialysis, such as dialysis-related amyloidosis, atherosclerosis and malnutrition. Copyright (C) 2005 S. Karger AG, Basel.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 33 条
  • [1] Effect of β2-microglobulin adsorption column on dialysis-related amyloidosis
    Abe, T
    Uchita, K
    Orita, H
    Kamimura, M
    Oda, M
    Hasegawa, H
    Kobata, H
    Fukunishi, M
    Shimazaki, M
    Abe, T
    Akizawa, T
    Ahmad, S
    [J]. KIDNEY INTERNATIONAL, 2003, 64 (04) : 1522 - 1528
  • [2] USING ULTRAPURE WATER IN HEMODIALYSIS DELAYS CARPAL-TUNNEL SYNDROME
    BAZ, M
    DURAND, C
    RAGON, A
    JABER, K
    ANDRIEU, D
    MERZOUK, T
    PURGUS, R
    OLMER, M
    REYNIER, JP
    BERLAND, Y
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (11) : 681 - 685
  • [3] Depner TA, 1996, J AM SOC NEPHROL, V7, P780
  • [4] A NEW FORM OF AMYLOID PROTEIN ASSOCIATED WITH CHRONIC-HEMODIALYSIS WAS IDENTIFIED AS BETA-2-MICROGLOBULIN
    GEJYO, F
    YAMADA, T
    ODANI, S
    NAKAGAWA, Y
    ARAKAWA, M
    KUNITOMO, T
    KATAOKA, H
    SUZUKI, M
    HIRASAWA, Y
    SHIRAHAMA, T
    COHEN, AS
    SCHMID, K
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1985, 129 (03) : 701 - 706
  • [5] Plasma levels of advanced glycation end products during haemodialysis, haemodiafiltration and haemofiltration: potential importance of dialysate quality
    Gerdemann, A
    Wagner, Z
    Solf, A
    Bahner, U
    Heidland, A
    Vienken, J
    Schinzel, R
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (06) : 1045 - 1049
  • [6] Results from EuCliD® (European clinical dialysis database):: Impact of shifting treatment modality
    Godino, JIM
    Rentero, R
    Orlandini, G
    Marcelli, D
    Ronco, C
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (11) : 1049 - 1060
  • [7] Hakim RM, 1996, J AM SOC NEPHROL, V7, P472
  • [8] The implications of water quality in hemodialysis
    Hoenich, NA
    Levin, R
    [J]. SEMINARS IN DIALYSIS, 2003, 16 (06) : 492 - 497
  • [9] Hsu PY, 2004, J NEPHROL, V17, P693
  • [10] Ultrapure dialysate decreases plasma pentosidine, a marker of "carbonyl stress"
    Izuhara, Y
    Miyata, T
    Saito, K
    Ishikawa, N
    Kakuta, T
    Nangaku, M
    Yoshida, H
    Saito, A
    Kurokawa, K
    de Strihou, CV
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2004, 43 (06) : 1024 - 1029