Rectification of the EMG is an unnecessary and inappropriate step in the calculation of Corticomuscular coherence

被引:93
作者
McClelland, Verity M. [1 ]
Cvetkovic, Zoran [2 ]
Mills, Kerry R. [1 ]
机构
[1] Kings Coll Hosp, Acad Unit Clin Neurophysiol, London SE5 9RS, England
[2] Kings Coll London, Dept Signal Proc & Informat, London WC2R 2LS, England
关键词
Cortico-muscular coherence; Rectified EMG; Unrectified EMG; EMG rectification; SURFACE EMG; MUSCLE-ACTIVITY; OSCILLATIONS; ELECTROMYOGRAMS; SYNCHRONIZATION; IDENTIFICATION; TASK; PRECISION; INPUT; DRIVE;
D O I
10.1016/j.jneumeth.2011.11.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Corticomuscular coherence (CMC) estimation is a frequency domain method used to detect a linear coupling between rhythmic activity recorded from sensorimotor cortex (EEG or MEG) and the electromyogram (EMG) of active muscles. In motor neuroscience, rectification of the surface EMG is a common pre-processing step prior to calculating CMC, intended to maximize information about action potential timing, whilst suppressing information relating to motor unit action potential (MUAP) shape. Rectification is believed to produce a general shift in the EMG spectrum towards lower frequencies, including those around the mean motor unit discharge rate. However, there are no published data to support the claim that EMG rectification enhances the detection of CMC. Furthermore, performing coherence analysis after the non-linear procedure of rectification, which results in a significant distortion of the EMG spectrum, is considered fundamentally flawed in engineering and digital signal processing. We calculated CMC between sensorimotor cortex EEG and EMG of two hand muscles during a key grip task in 14 healthy subjects. CMC calculated using unrectified and rectified EMG was compared. The use of rectified EMG did not enhance the detection of CMC, nor was there any evidence that MUAP shape information had an adverse effect on the CMC estimation. EMG rectification had inconsistent effects on the power and coherence spectra and obscured the detection of CMC in some cases. We also provide a comprehensive theoretical analysis, which, along with our empirical data, demonstrates that rectification is neither necessary nor appropriate in the calculation of CMC. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 201
页数:12
相关论文
共 28 条
[1]  
[Anonymous], 1977, DISCRETE TIME SIGNAL
[2]  
[Anonymous], 1971, Random Data: Analysis and Measurement Procedures
[3]   The effect of diazepam on motor cortical oscillations and corticomuscular coherence studied in man [J].
Baker, MR ;
Baker, SN .
JOURNAL OF PHYSIOLOGY-LONDON, 2003, 546 (03) :931-942
[4]   The role of synchrony and oscillations in the motor output [J].
Baker, SN ;
Kilner, JM ;
Pinches, EM ;
Lemon, RN .
EXPERIMENTAL BRAIN RESEARCH, 1999, 128 (1-2) :109-117
[5]   The Nature of Periodic Input to the Muscles [J].
Boonstra, Tjeerd W. .
JOURNAL OF NEUROPHYSIOLOGY, 2010, 104 (01) :576-576
[6]   HIGH-FREQUENCY OSCILLATIONS IN HUMAN RESPIRATORY ELECTROMYOGRAMS DURING VOLUNTARY BREATHING [J].
BRUCE, EN ;
GOLDMAN, MD .
BRAIN RESEARCH, 1983, 269 (02) :259-265
[7]   Identification of Oscillations in Muscle Activity From Surface EMG: Reply to Halliday and Farmer [J].
Christou, Evangelos ;
Neto, Osmar .
JOURNAL OF NEUROPHYSIOLOGY, 2010, 103 (06) :3548-3549
[8]   Synchronization between motor cortex and spinal motoneuronal pool during the performance of a maintained motor task in man [J].
Conway, BA ;
Halliday, DM ;
Farmer, SF ;
Shahani, U ;
Maas, P ;
Weir, AI ;
Rosenberg, JR .
JOURNAL OF PHYSIOLOGY-LONDON, 1995, 489 (03) :917-924
[9]   AAEM MINIMONOGRAPH .10. VOLUME CONDUCTION [J].
DUMITRU, D ;
DELISA, JA .
MUSCLE & NERVE, 1991, 14 (07) :605-624
[10]   The extraction of neural strategies from the surface EMG [J].
Farina, D ;
Merletti, R ;
Enoka, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (04) :1486-1495