Estrogen and progesterone effects on transcapillary fluid dynamics

被引:36
作者
Stachenfeld, NS
Keefe, DL
Palter, SF
机构
[1] John B Pierce Fdn Lab, New Haven, CT 06519 USA
[2] Yale Univ, Sch Med, Dept Epidemiol & Publ Hlth, New Haven, CT 06519 USA
[3] Yale Univ, Sch Med, Dept Obstet & Gynecol, Div Reprod Endocrinol, New Haven, CT 06519 USA
[4] Brown Univ, Women & Infants Hosp, Sch Med, Providence, RI 02905 USA
关键词
plasma volume; interstitial fluid; capillary filtration coefficient;
D O I
10.1152/ajpregu.2001.281.4.R1319
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to determine estrogen (E-2) and progesterone (P-4) effects on atrial natriuretic peptide (ANP) control of plasma volume (PV) and transcapillary fluid dynamics. To this end, we suppressed reproductive function in 12 women (age 21-35 yr) using a gonadotropin releasing-hormone (GnRH) analog (leuprolide acetate) for 5 wk. During the 5th week, the women either received 4 days of E-2 administration (17 beta -estradiol, transdermal patch, 0.1 mg/day) or 4 days of E-2 with P-4 administration (vaginal gel, 90 mg P-4 twice per day). At the end of the 4th and 5th week of GnRH analog and hormone administration, we determined PV (Evans blue dye) and changes in PV and forearm capillary filtration coefficient (CFC) during a 120-min infusion of ANP (5 ng . kg body wt(-1) . min(-1)). Preinfusion PV was estimated from Evans blue dye measurement taken over the last 30 min of infusion based on changes in hematocrit. E-2 treatment did not affect preinfusion PV relative to GnRH analog alone (45.3 +/- 3.1 vs. 45.4 +/- 3.1 ml/kg). During ANP infusion CFC was greater during E-2 treatment compared with GnRH analog alone (6.5 +/- 1.4 vs. 4.9 +/- 1.4 mul . 100 g(-1) . min(-1) mmHg(-1), P< 0.05). The %PV loss during ANP infusion was similar for E-2 and GnRH analog-alone treatments (-0.8 +/- 0.2 and -1.0 +/- 0.2 ml/kg, respectively), indicating the change in CFC had little systemic effect on ANP-related changes in PV. Estimated baseline PV was reduced by E-2-P-4 treatment. During ANP infusion CFC was <similar to>30% lower during E-2-P-4 (6.0 +/- 0.5 vs. 4.3 +/- 4.3 mul . 100 g(-1) . min(-1) mmHg(-1), P< 0.05), and the PV loss during ANP infusion was attenuated (-0.9 +/- 0.2 and -0.2 +/- 0.2 ml/kg for GnRH analog-alone and E-2-P-4 treatments, respectively). Thus the E-2-P-4 treatment lowered CFC and reduced PV loss during ANP infusion.
引用
收藏
页码:R1319 / R1329
页数:11
相关论文
共 33 条
  • [1] DIVERSE BIOLOGICAL ACTIONS OF ATRIAL-NATRIURETIC-PEPTIDE
    BRENNER, BM
    BALLERMANN, BJ
    GUNNING, ME
    ZEIDEL, ML
    [J]. PHYSIOLOGICAL REVIEWS, 1990, 70 (03) : 665 - 699
  • [2] COLTON T, 1974, STAT MED, P142
  • [3] ANP-MEDIATED VOLUME DEPLETION ATTENUATES RENAL RESPONSES IN HUMANS
    EBERT, TJ
    GROBAN, L
    MUZI, M
    HANSON, M
    COWLEY, AW
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (06): : R1303 - R1308
  • [4] Transvaginal administration of progesterone
    Fanchin, R
    DeZiegler, D
    Bergeron, C
    Righini, C
    Torrisi, C
    Frydman, R
    [J]. OBSTETRICS AND GYNECOLOGY, 1997, 90 (03) : 396 - 401
  • [5] Epidemiology, pathophysiology, and management of hyponatremic encephalopathy
    Fraser, CL
    Arieff, AI
    [J]. AMERICAN JOURNAL OF MEDICINE, 1997, 102 (01) : 67 - 77
  • [6] Effects of estrogen in vivo on coronary vascular resistance in perfused rabbit hearts
    Gorodeski, GI
    Yang, T
    Levy, MN
    Goldfarb, J
    Utian, WH
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 1995, 269 (06) : R1333 - R1338
  • [7] PLASMA-VOLUME DURING STRESS IN MAN - OSMOLALITY AND RED-CELL VOLUME
    GREENLEAF, JE
    CONVERTINO, VA
    MANGSETH, GR
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (05) : 1031 - 1038
  • [8] GROBAN L, 1989, AM J PHYSIOL-HEART C, V256, pH258
  • [9] Hytten FE, 1970, INT J GYNECOL OBSTET, V33, P133
  • [10] CAPILLARY FILTRATION MEASUREMENT BY STRAIN-GAUGE .1. ANALYSIS OF METHODS
    KATZ, MA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 232 (04): : H354 - H360