Fracture toughness of glass ionomers measured with two different methods

被引:23
作者
Alvanforoush, Negin [1 ]
Wong, Rebecca [1 ]
Burrow, Michael [1 ,2 ]
Palamara, Joseph [1 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, 720 Swanston St, Carlton, Vic 3053, Australia
[2] Univ Hong Kong, Prince Philip Dent Hosp, Fac Dent, Sai Ying Pun, 34 Hosp Rd, Hong Kong, Peoples R China
关键词
Glass Ionomer Cement; Fracture toughness; Artificial saliva; Compact tension test; 4-point bending test; PHYSICAL-PROPERTIES; SURFACE TREATMENTS; WATER-MOVEMENT; BEHAVIOR; CEMENT; PERFORMANCE; VARNISHES; HARDNESS;
D O I
10.1016/j.jmbbm.2018.09.020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Glass Ionomer Cements (GICs) are brittle materials with low fracture toughness and strength. Therefore, understanding the fracture toughness is an important parameter to know, due to GICs being promoted for load-bearing restorations. Also, little is known about the effects of artificial saliva (AS) on fracture toughness of GICs. This project aimed to study the effects of storage and compare two different fracture toughness test methods, namely: Compact-Tension test and 4-point bending test. Samples were made from a Zinc-reinforced-GIC (ChemFil), High viscosity bulk-fill-GIC (HV) with and without LC-coating (EQUIA), Resin-Modified GIC (RM-GIC) (Riva-LC), HV-RMGIC (Riva-HV-LC) and flowable bulk-fill Giomer (Beautifil-Bulk Flowable) using a custom-made mould. Specimens were stored in either AS or distilled-water (DW) for 7 or 30 days, After storage, specimens were tested for fracture toughness. Results were analysed with Analysis of variance (ANOVA), Mann-Whitney and Weibull statistics. ANOVA showed a significant difference (P < 0.05) between methods, however the same trend among materials was observed in both methods. Some materials showed significantly higher values for samples stored in DW and others revealed the same trend but were not significant. Significantly higher (P < 0.05) mean fracture toughness values were observed for materials stored for 30 days. Since both fracture toughness test methods revealed the same fracture toughness strength order among materials, either test appears appropriate. GICs maturation led to a difference between 7 and 30-day results. The AS used had a high ionic strength compared to DW, which may have led to increased solubility of GICs and consequently to the reduced fracture toughness values. The results revealed that coating the GIC has a protective effect against storage media.
引用
收藏
页码:208 / 216
页数:9
相关论文
共 51 条
  • [1] Comparison between published clinical success of direct resin composite restorations in vital posterior teeth in 1995-2005 and 2006-2016 periods
    Alvanforoush, N.
    Palamara, J.
    Wong, R. H.
    Burrow, M. F.
    [J]. AUSTRALIAN DENTAL JOURNAL, 2017, 62 (02) : 132 - 145
  • [2] [Anonymous], 2012, 2314620122 ISO
  • [3] [Anonymous], 2015, 6872 ISO
  • [4] [Anonymous], E39912E3 ASTM
  • [5] Bagheri R, 2010, AM J DENT, V23, P142
  • [6] Fracture toughness testing: A discriminatory mechanical testing performance indicator for glass-ionomer restoratives?
    Baig, Mirza Shahzad
    Lloyd, Charles H.
    Fleming, Garry J. P.
    [J]. DENTAL MATERIALS, 2015, 31 (08) : 877 - 886
  • [7] Burrow M.F., 2013, COMPOSITE ADHESIVE R, P235
  • [8] Crisp S, 1976, J Dent, V4, P162, DOI 10.1016/0300-5712(76)90025-7
  • [9] Water uptake and strength characteristics of a nanofilled resin-based composite
    Curtis, A. R.
    Shortall, A. C.
    Marquis, P. M.
    Palin, W. M.
    [J]. JOURNAL OF DENTISTRY, 2008, 36 (03) : 186 - 193
  • [10] Leaching and mechanical properties characterization of dental composites
    Drummond, JL
    Andronova, K
    Al-Turki, LI
    Slaughter, LD
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 71B (01) : 172 - 180