Thin-film IrOx pH microelectrode for microfluidic-based microsystems

被引:101
作者
Ges, IA [1 ]
Ivanov, BL [1 ]
Schaffer, DK [1 ]
Lima, EA [1 ]
Werdich, AA [1 ]
Baudenbacher, FJ [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Stevenson Ctr 6301, VU Stn B 351631, Nashville, TN 37235 USA
关键词
iridium oxide films; electrochemical deposition; pH sensor; microfluidic device; cell acidification rate;
D O I
10.1016/j.bios.2004.09.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Microsensors are valuable tools to monitor cell metabolism in cell culture volumes. The present research describes the fabrication and characterization of on-chip thin-film iridium, oxide pH microsensors with dimensions of 20 mu m x 20 mu m and 20 mu m x 40 mu m suitable to be incorporated into nl volumes. IrOx thin films were formed on platinum microelectrodes by electrochemical deposition in galvanostatic mode. Anodically grown iridium oxide films showed a near super-Nernstian response with a slope of -77.6 +/- 2 mV/pH at 22 degrees C, and linear responses within the pH range of 4-11. Freshly deposited electrodes showed response times as low as 6 s. Long-term studies showed a baseline drift of 2-3 mv/month, which could easily be compensated by calibration. This work demonstrated for the first time the use of planar IrOx pH microelectrodes to measure the acidification rate of CHO and fibroblast cells in an on chip cell culture volume of 25 nl with microfluidic control. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:248 / 256
页数:9
相关论文
共 40 条
[1]   PROPERTIES OF THERMALLY PREPARED IRIDIUM DIOXIDE ELECTRODES [J].
ARDIZZONE, S ;
CARUGATI, A ;
TRASATTI, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 126 (1-3) :287-292
[2]   Microelectronic sensor system for microphysiological application on living cells [J].
Baumann, WH ;
Lehmann, M ;
Schwinde, A ;
Ehret, R ;
Brischwein, M ;
Wolf, B .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (01) :77-89
[3]   Electrochemical deposition of iridium(IV) oxide from alkaline solutions of iridium(III) oxide [J].
Baur, JE ;
Spaine, TW .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 443 (02) :208-216
[4]   Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies [J].
Bezbaruah, AN ;
Zhang, TC .
ANALYTICAL CHEMISTRY, 2002, 74 (22) :5726-5733
[5]   PREPARATION OF AN OXIDIZED IRIDIUM ELECTRODE AND THE VARIATION OF ITS POTENTIAL WITH PH [J].
BURKE, LD ;
MULCAHY, JK ;
WHELAN, DP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 163 (1-2) :117-128
[6]   Modeling the response time of an in vivo glucose affinity sensor [J].
Clark, HR ;
Barbari, TA ;
Rao, G .
BIOTECHNOLOGY PROGRESS, 1999, 15 (02) :259-266
[7]   A microphysiometer for simultaneous measurement of changes in extracellular glucose, lactate, oxygen, and acidification rate [J].
Eklund, SE ;
Taylor, D ;
Kozlov, E ;
Prokop, A ;
Cliffel, DE .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :519-527
[8]   A BioMEMS review: MEMS technology for physiologically integrated devices [J].
Grayson, ACR ;
Shawgo, RS ;
Johnson, AM ;
Flynn, NT ;
Li, YW ;
Cima, MJ ;
Langer, R .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :6-21
[9]   Cytosensor® Microphysiometer:: technology and recent applications [J].
Hafner, F .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :149-158
[10]   A method of reducing oxygen induced drift in iridium oxide pH sensors [J].
Hendrikse, J ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :97-103