Estimation of the minimum uncertainty of DNA concentration in a genetically modified maize sample candidate certified reference material

被引:16
作者
Prokisch, J [1 ]
Zeleny, R [1 ]
Trapmann, S [1 ]
Le Guern, L [1 ]
Schimmel, H [1 ]
Kramer, GN [1 ]
Pauwels, J [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, EC, JRC,IRMM, B-2440 Geel, Belgium
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 370卷 / 07期
关键词
D O I
10.1007/s002160100859
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Homogeneity testing and the determination of minimum sample mass are an important part of the certification of reference materials. The smallest theoretically achievable uncertainty of certified concentration values is limited by the concentration distribution of analyte in the different particle size fractions of powdered biological samples. This might be of special importance if the reference material is prepared by dry mixing, a dilution technique which is used for the production of the new and third generation of genetically modified (GMO) plant certified reference materials. For the production of dry mixed PMON 810 maize reference material a computer program was developed to calculate the theoretically smallest uncertainty for a selected sample intake. This model was used to compare three differently milled maize samples, and the effect of dilution on the uncertainty of the DNA content of GMO maize was estimated as well. In the case of a 50-mg sample mass the lowest achievable standard deviation was 2% for the sample containing 0.1% GMO and the minimum deviation was less than 0.5% for the sample containing 5% GMO.
引用
收藏
页码:935 / 939
页数:5
相关论文
共 6 条
  • [1] The production of powdered candidate biological and environmental reference materials in the laboratories of the Joint Research Centre
    Kramer, GN
    Muntau, H
    Maier, E
    Pauwels, J
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (3-4): : 299 - 303
  • [2] The preparation of biological and environmental reference materials
    Kramer, GN
    Pauwels, J
    [J]. MIKROCHIMICA ACTA, 1996, 123 (1-4) : 87 - 93
  • [3] Homogeneity testing of reference materials
    Pauwels, J
    Lamberty, A
    Schimmel, H
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 1998, 3 (02) : 51 - 55
  • [4] DETERMINATION OF THE MINIMUM SAMPLE MASS OF A SOLID CRM TO BE USED IN CHEMICAL-ANALYSIS
    PAUWELS, J
    VANDECASTEELE, C
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (2-4): : 121 - 123
  • [5] TRAPMANN S, 2000, 8 INT S BIOL ENV REF
  • [6] [No title captured]