Tonometry after laser in situ keratomileusis treatment

被引:74
|
作者
Duch, S
Serra, A
Castanera, J
Abos, R
Quintana, M
机构
[1] Univ Barcelona, Dept Ophthalmol, E-08007 Barcelona, Spain
[2] Univ Barcelona, Ciudad Sanitaria & Univ Bellvitge, Dept Clin Epidemiol, E-08007 Barcelona, Spain
[3] Inst Oftalmol Castanera, Barcelona, Spain
关键词
contact pneumotonometry; Goldmann applanation tonometry; intraocular pressure; laser keratomileusis; refractive surgery;
D O I
10.1097/00061198-200108000-00003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reliability of intraocular pressure measurements by Goldmann applanation tonometry versus pneumotonometry after laser in situ keratomileusis for myopia. Patients and Methods: In this prospective study, corneal Goldmann applanation tonometry and pneumotonometry measurements were made in 118 eyes of 60 patients before and 1 and 3 months after undergoing laser in situ keratomileusis for myopia. Manifest refraction, ultrasonic corneal thickness measurements, and keratometry readings were also obtained. Results: Preoperative intraocular pressure showed a good correlation between Goldmann applanation tonometry and pneumotonometry values (Pearson r = 0.71; P < 0.001). although Goldmann applanation tonometry readings were slightly higher at low intraocular pressure values and slightly lower at high intraocular pressure values. After a mean stromal ablation depth of 77.1 mum. mean intraocular pressure by Goldmann applanation tonometry decreased significantly (P < 0.001) from a preoperative value of 14.8 +/- 11.9 mm Hg to 11.9 +/- 2.1 mm Hg and 11.7 +/- 1.7 mm Hg after 1 and 3 months, respectively. Mean pre- and post-laser in situ keratomileusis measurements by pneumotonometry were similar (P = 0.8). Differences of postoperative intraocular pressure measurements by Goldmann applanation tonometry and pneumotonometry were statistically significant. After 3 months, there was a poor correlation between Goldmann applanation tonometry and pneumotonometry intraocular pressure values (Pearson r = 0.58). Postoperative intraocular pressure decrease in applanation tonometry correlated with changes in keratometry, spherical equivalent, and central corneal thickness. Regression analysis showed a decrease of 2.9 mm Hg per 70 mum reduction in central corneal thickness. Conclusions: Contact pneumotonometry measures the IOP reliably after laser in situ keratomileusis for myopia, whereas Goldmann applanation tonometry underestimates the intraocular pressure. This may be important in the treatment of any future glaucoma.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 50 条
  • [31] Pressure-Induced Interlamellar Stromal Keratitis After Laser In Situ Keratomileusis
    Tourtas, Theofilos
    Kopsachilis, Nikolaos
    Meiller, Ralph
    Kruse, Friedrich E.
    Cursiefen, Claus
    CORNEA, 2011, 30 (08) : 920 - 923
  • [32] THE MANAGEMENT OF EPITHELIAL INGROWTHAFTER LASER IN SITU KERATOMILEUSIS
    杨斌
    王铮
    陈家祺
    ChineseMedicalSciencesJournal, 2001, (04) : 241 - 243
  • [33] Complications of laser-assisted in situ keratomileusis
    Sahay, Pranita
    Bafna, Rahul Kumar
    Reddy, Jagadesh C.
    Vajpayee, Rasik B.
    Sharma, Namrata
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (07) : 1658 - 1669
  • [34] Clinical evaluation of a new correction Check for updatem algorithm for dynamic Scheimpflug analyzer tonometry before and after laser in situ keratomileusis and small-incision lenticule extraction
    Chen, Kai-Jung
    Joda, Akram
    Vinciguerra, Riccardo
    Eliasy, Ashkan
    Sefat, Shervin Mir Mohi
    Kook, Daniel
    Geraghty, Brendan
    Roberts, Cynthia J.
    Elsheikh, Ahmed
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (05) : 581 - 588
  • [35] Changes in Biomechanical Properties of the Cornea and Intraocular Pressure After Myopic Laser In Situ Keratomileusis Using a Femtosecond Laser for Flap Creation Determined Using Ocular Response Analyzer and Goldmann Applanation Tonometry
    Shin, Jonghoon
    Kim, Tae Won
    Park, Soo Jeong
    Yoon, Min
    Lee, Ji Woong
    JOURNAL OF GLAUCOMA, 2015, 24 (03) : 195 - 201
  • [36] Assessment of ocular hemodynamics after laser in situ keratomileusis using color Doppler imaging
    Waleed Abu Samera
    Maha Shahin
    Hatem El-Awady
    Ashraf Abd El-Rahman
    Nahed El-Toukhy
    International Ophthalmology, 2014, 34 : 269 - 275
  • [37] Evaluation of the Retinal Nerve Fiber Layer and Ganglion Cell Layer After Laser-Assisted in situ Keratomileusis, Femtosecond-Laser in-situ Keratomileusis, and Small Incision Lenticule Extraction Using Optical Coherence Tomography
    Shaaban, Yasmine Maher
    Badran, Tamer Abdel Fattah
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 973 - 984
  • [38] Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
    Helmy, Hazem
    Hashem, Omar
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 509 - 516
  • [39] Corneal Aberrations and Visual Acuity After Laser In Situ Keratomileusis: Femtosecond Laser Versus Mechanical Microkeratome
    Calvo, Ramon
    Mclaren, Jay W.
    Hodge, David O.
    Bourne, William M.
    Patel, Sanjay V.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (05) : 785 - 793
  • [40] Goldmann and modified Goldmann tonometry measuring intraocular pressure changes in eyes which underwent myopic laser in situ Keratomileusis and photorefractive keratectomy
    Ang, Robert Edward T.
    Rixon, Andrew
    Kilgore, Khin
    Schweitzer, Justin
    BMC OPHTHALMOLOGY, 2022, 22 (01)