Simultaneous Determination of Ticagrelor and Its Metabolites in Human Plasma and Urine Using Liquid Chromatography-Tandem Mass Spectrometry

被引:19
|
作者
Zhong, Wanping [1 ,2 ]
Wang, Xipei [2 ]
Tang, Lan [1 ]
Mai, Liping [2 ]
Chen, Xiao-Ping [3 ,4 ]
He, Guodong [2 ]
Zheng, Zhijie [2 ]
Zhong, Shilong [2 ]
机构
[1] Southern Med Univ, Sch Pharmaceut Sci, Guangdong Prov Key Lab New Drug Screening, Guangzhou 510515, Guangdong, Peoples R China
[2] Guangdong Acad Med Sci, Guangdong Cardiovasc Inst, Guangdong Gen Hosp, Med Res Ctr, 106 Zhongshan Rd,Weilun Bldg 1112, Guangzhou 510080, Guangdong, Peoples R China
[3] Cent S Univ, Xiangya Hosp, Dept Clin Pharmacol, Changsha 410008, Hunan, Peoples R China
[4] Cent S Univ, Inst Clin Pharmacol, Pharmacogenet Res Inst, Changsha 410008, Hunan, Peoples R China
关键词
PHARMACODYNAMICS; PHARMACOKINETICS; ANTAGONIST; SAFETY;
D O I
10.1093/jat/bkw039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed and validated a rapid, selective and sensitive method using high-performance liquid chromatography-tandem mass spectrometry (MS) for the quantification of ticagrelor and all of its as-yet-identified metabolites in human plasma and urine. For the analysis of ticagrelor, its metabolites and the internal standard (IS) plasma samples were processed by liquid-liquid extraction using ethyl acetate and urine was processed by protein precipitation. Separations were performed on an Ultimate XB-C-18 column (2.1 mm x 150 mm, 3 mu m), using aqueous ammonium acetate (0.025 mM)/acetonitrile (35 : 65, v:v) as the mobile phase. Ticagrelor and all 11 metabolites were eluted within 4.5 min. Quantification was performed using electrospray ionization, operating in negative ion mode. The ticagrelor and metabolite M8 (AR-C124910XX) responses were optimized at the m/z 521.2 -> 361.2 and m/z 477.2 -> 361.1 transitions, respectively. The assay was validated over the linear range of 0.5-2,000 ng/mL for ticagrelor and M8. The intra- and inter-assay precisions were a parts per thousand currency sign14.6% for ticagrelor and a parts per thousand currency sign14.7% for M8, respectively. The matrix effects of plasma and urine were in the range of 98.3-110.7% for ticagrelor and 102.1-112.3% for M8. The relative quantification of other metabolites was performed by assessing the ratio of metabolite to IS peaks. The newly developed method was successfully used in a pharmacokinetic study characterizing ticagrelor metabolism in human volunteers.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 50 条
  • [21] Simultaneous determination of thymine and its sequential catabolites dihydrothymine and β-ureidoisobutyrate in human plasma and urine using liquid chromatography-tandem mass spectrometry with pharmacokinetic application
    Ni, Ming
    Duley, John
    George, Rani
    Charles, Bruce
    Shannon, Catherine
    McGeary, Ross
    Norris, Ross
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 : 129 - 135
  • [22] Simultaneous Determination of Artemether and Its Major Metabolites Dihydroartimisinin in Rat Plasma Using Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Li Chun
    Qiu Yu-Qin
    Yang Guo-Zhong
    Meng Fan-Da
    Zhang Suo-Hui
    Gao Yun-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (04) : 560 - 565
  • [23] Determination of raloxifene and its glucuronides in human urine by liquid chromatography-tandem mass spectrometry assay
    Trdan, Tina
    Roskar, Robert
    Trontelj, Jurij
    Ravnikar, Matjaz
    Mrhar, Ales
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2323 - 2331
  • [24] Determination of silodosin in human plasma by liquid chromatography-tandem mass spectrometry
    Zhao, Xia
    Liu, Yuwang
    Xu, Junyu
    Zhang, Dan
    Zhou, Ying
    Gu, Jingkai
    Cui, Yimin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (29): : 3724 - 3728
  • [25] Determination of nicousamide in human plasma by liquid chromatography-tandem mass spectrometry
    Qi, Wenyuan
    Zhao, Qian
    Liu, Hongzhong
    Jiang, Ji
    Chen, Xiaoguang
    Hu, Pei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 77 : 158 - 162
  • [26] Liquid Chromatography-Tandem Mass Spectrometry Method for Ticagrelor and its Active Metabolite Determination in Human Plasma: Application to a Pharmacokinetic Study
    Marsousi, Niloufar
    Rudaz, Serge
    Desmeules, Jules A.
    Daali, Youssef
    CURRENT ANALYTICAL CHEMISTRY, 2020, 16 (05) : 602 - 608
  • [27] Determination of solifenacin in human plasma by liquid chromatography-tandem mass spectrometry
    Macek, Jan
    Ptacek, Pavel
    Klima, Josef
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3327 - 3330
  • [28] Determination of celecoxib in human plasma by liquid chromatography-tandem mass spectrometry
    Ptacek, Pavel
    Klima, Josef
    Macek, Jan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 163 - 166
  • [29] Determination of tropisetron in human plasma by liquid chromatography-tandem mass spectrometry
    Deng, Pan
    Zhong, Dafang
    Chen, Xiaoyan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) : 848 - 852
  • [30] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in human plasma
    Wang, Haidong
    Deng, Pan
    Chen, Xiaoyan
    Guo, Lixia
    Zhong, Dafang
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 34 - 38