Single-level cervical disc arthroplasty in the spine with reversible kyphosis: A finite element study

被引:1
|
作者
Hu, Xu [1 ,2 ]
Jiang, Majiao [3 ]
Hong, Ying [3 ]
Rong, Xin [1 ]
Huang, Kangkang [1 ]
Liu, Hao [1 ]
Pu, Dan [4 ]
Wang, Beiyu [1 ]
机构
[1] Sichuan Univ, Orthoped Res Inst, Dept Orthoped, West China Hosp, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
[2] City Univ Hong Kong, Dept Biomed Engn, Hong Kong, Peoples R China
[3] Sichuan Univ, West China Hosp, West China Sch Nursing, Dept Anesthesia & Operat Ctr, Chengdu, Sichuan, Peoples R China
[4] Sichuan Univ, Clin Skill Ctr, West China Hosp, Chengdu, Sichuan, Peoples R China
来源
JOR SPINE | 2022年 / 5卷 / 02期
基金
中国国家自然科学基金;
关键词
anterior cervical discectomy and fusion; biomechanics; cervical disc arthroplasty; finite element analysis; reversible kyphosis; SAGITTAL ALIGNMENT; FUSION; DISKECTOMY; DEGENERATION; REPLACEMENT; ACDF;
D O I
10.1002/jsp2.1194
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Our previous studies found the single-level cervical disc arthroplasty (CDA) might be a feasible treatment for the patients with reversible kyphosis (RK). Theoretically, the change of cervical alignment from lordosis to RK comes with the biomechanical alteration of prostheses and cervical spine. However, the biomechanical data of CDA in the spine with RK have not been reported. This study aimed at establishing finite element (FE) models to (1) explore the effects of RK on the biomechanics of artificial cervical disc; (2) investigate the biomechanical differences of single-level anterior cervical discectomy and fusion (ACDF) and CDA in the cervical spine with RK. Methods The FE models of the cervical spine with lordosis and RK were constructed, then three single-level surgical models were developed: (1) RK + ACDF; (2) RK + CDA; (3) lordosis + CDA. A 73.6-N follower load combined with 1 N center dot m moment was applied at the C2 vertebra to produce cervical motion. Results At the surgical level, "lordosis + CDA" had the greatest ROM (except for flexion) while "RK + ACDF" had the minimum ROM. However, at adjacent levels, the ROM of "RK + ACDF" increased by 4.05% to 38.04% in comparison to "RK + CDA." "RK + ACDF" had the greatest prosthesis interface stress, while the maximum prosthesis interface stress of "RK + CDA" was at least 2.15 times higher than "lordosis + CDA." Similarly, "RK + ACDF" had the greatest intradiscal pressure (IDP) at adjacent levels, while the IDP of "RK + CDA" was 1.6 to 6.7 times higher than "lordosis + CDA." At the surgical level, "RK + CDA" had the greatest facet joint stress (except for extension), which was 1.9 to 11.2 times higher than "lordosis + CDA." At the adjacent levels, "RK + CDA" had the greatest facet joint stress (except for extension), followed by "RK + ACDF" and "lordosis + CDA" in descending order. Conclusions RK significantly changed the biomechanics of CDA, which is demonstrated by the decreased ROM and the significantly increased prosthesis interface stress, IDP, and facet joint stress in the "RK + CDA" model. Compared with ACDF, CDA overall exhibited a better biomechanical performance in the cervical spine with RK, with the increased ROM of surgical level and facet joint stress and the decreased ROM of adjacent levels, prosthesis interface stress, and IDP.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Clinical and radiologic comparison of dynamic cervical implant arthroplasty and cervical total disc replacement for single-level cervical degenerative disc disease
    Liu Shichang
    Song Yueming
    Liu Limin
    Wang Lei
    Zhou Zhongjie
    Zhou Chunguang
    Yang Xi
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 27 : 102 - 109
  • [22] Risk Factors for Reoperation Following Single-Level Cervical Disc Arthroplasty as Utilized in a Representative Sample of United States Clinical Practice: A Retrospective PearlDiver Study
    Nilssen, Paal K.
    Narendran, Nakul
    Chen, Ida
    Kanim, Linda E.
    Walker, Corey T.
    Bae, Hyun W.
    Skaggs, David L.
    Tuchman, Alexander
    GLOBAL SPINE JOURNAL, 2025, 15 (02) : 1186 - 1192
  • [23] A meta-analysis of cervical arthroplasty compared to anterior cervical discectomy and fusion for single-level cervical disc disease
    Xing, Dan
    Ma, Xin-Long
    Ma, Jian-Xiong
    Wang, Jie
    Ma, Tao
    Chen, Yang
    JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (07) : 970 - 978
  • [24] Adjacent level effects of bi level disc replacement, hi level fusion and disc replacement plus fusion in cervical spine- a finite element based study
    Faizan, Ahmad
    Goel, Vijay K.
    Biyani, Ashok
    Garfin, Steven R.
    Bono, Christopher M.
    CLINICAL BIOMECHANICS, 2012, 27 (03) : 226 - 233
  • [25] Is single-level cervical disc arthroplasty associated with a lower reoperation rate than anterior cervical discectomy and fusion?
    Tuchman, Alexander
    Chen, Ida
    Walker, Corey T.
    Kanim, Linda E.
    Bae, Hyun W.
    Skaggs, David L.
    JOURNAL OF NEUROSURGERY-SPINE, 2024, 40 (03) : 282 - 290
  • [26] Is single-level cervical disc arthroplasty associated with a lower reoperation rate than anterior cervical discectomy and fusion?
    Tuchman, Alexander
    Chen, Ida
    Walker, Corey T.
    Kanim, Linda E.
    Bae, Hyun W.
    Skaggs, David L.
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 40 (03) : 282 - 290
  • [27] Biomechanics following skip-level cervical disc arthroplasty versus skip-level cervical discectomy and fusion: a finite element-based study
    Wu, Ting-kui
    Meng, Yang
    Wang, Bei-yu
    Rong, Xin
    Hong, Ying
    Ding, Chen
    Chen, Hua
    Liu, Hao
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [28] Cochrane in CORR A® : Arthroplasty Versus Fusion in Single-level Cervical Degenerative Disc Disease
    Evaniew, Nathan
    Madden, Kim
    Bhandari, Mohit
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (03) : 802 - 808
  • [29] Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis
    Ryu, Won Hyung A.
    Kowalczyk, Izabela
    Duggal, Neil
    SPINE JOURNAL, 2013, 13 (06) : 628 - 634
  • [30] Single-level cervical arthroplasty with ProDisc-C artificial disc: 10-year follow-up results in one centre
    Zhao, Yanbin
    Zhou, Feifei
    Sun, Yu
    Pan, Shengfa
    EUROPEAN SPINE JOURNAL, 2020, 29 (11) : 2670 - 2674