Effect of biomimetic conditions on mechanical and structural integrity of PGA/P4HB and electrospun PCL scaffolds

被引:31
|
作者
Klouda, Leda [1 ,2 ]
Vaz, Claudia M. [2 ]
Mol, Anita [2 ]
Baaijens, Frank P. T. [2 ]
Bouten, Carlijn V. C. [2 ]
机构
[1] Rice Univ, Dept Bioengn, Houston, TX 77251 USA
[2] Eindhoven Univ Technol, Dept Biomed Engn, Div Biomech & Tissue Engn, NL-5600 MB Eindhoven, Netherlands
关键词
D O I
10.1007/s10856-007-0171-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The selection of an appropriate scaffold represents one major key to success in tissue engineering. In cardiovascular applications, where a load-bearing structure is required, scaffolds need to demonstrate sufficient mechanical properties and importantly, reliable retention of these properties during the developmental phase of the tissue engineered construct. The effect of in vitro culture conditions, time and mechanical loading on the retention of mechanical properties of two scaffold types was investigated. First candidate tested was a poly-glycolic acid non-woven fiber mesh, coated with poly-4-hydroxybutyrate (PGA/P4HB), the standard scaffold used successfully in cardiovascular tissue engineering applications. As an alternative, an electrospun poly-epsilon-caprolactone (PCL) scaffold was used. A 15-day dynamic loading protocol was applied to the scaffolds. Additionally, control scaffolds were incubated statically. All studies were performed in a simulated physiological environment (phosphate-buffered saline solution, T = 37C). PGA/P4HB scaffolds showed a dramatic decrease in mechanical properties as a function of incubation time and straining. Mechanical loading had a significant effect on PCL scaffold properties. Degradation as well as fiber fatigue caused by loading promote loss of mechanical properties in PGA/P4HB scaffolds. For PCL, fiber reorganization due to straining seems to be the main reason behind the brittle behavior that was pronounced in these scaffolds. It is suggested that those changes in scaffolds' mechanical properties must be considered at the application of in vitro tissue engineering protocols and should ideally be taken over by tissue formation to maintain mechanically stable tissue constructs.
引用
收藏
页码:1137 / 1144
页数:8
相关论文
共 12 条
  • [1] Effect of biomimetic conditions on mechanical and structural integrity of PGA/P4HB and electrospun PCL scaffolds
    Leda Klouda
    Claudia M. Vaz
    Anita Mol
    Frank P. T. Baaijens
    Carlijn V. C. Bouten
    Journal of Materials Science: Materials in Medicine, 2008, 19 : 1137 - 1144
  • [2] Investigating the effect of PGA on physical and mechanical properties of electrospun PCL/PGA blend nanofibers
    Aghdam, Rouhollah Mehdinavaz
    Najarian, Siamak
    Shakhesi, Saeed
    Khanlari, Samaneh
    Shaabani, Keyvan
    Sharifi, Shahriar
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 124 (01) : 123 - 131
  • [3] Tailoring the Mechanical Properties and Foaming Behaviors of PLA/P4HB Blends by Using P4HB-g-GMA as Compatibilizer
    Li, Mingjiao
    Chen, Xinyi
    Feng, Qiyang
    Fan, Wanyi
    Ding, Yitong
    Kan, Ze
    Li, Zhibo
    JOURNAL OF POLYMER SCIENCE, 2025, 63 (01) : 204 - 212
  • [4] The effect of solvent systems on structural properties of electrospun PCL-gelatin nanofibrous composite scaffolds
    Vatankhah, E.
    Ajalloueian, F.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 214 - 214
  • [5] Structural and functional characterization of the alternative splicing isoform P4HB-021 of the human protein disulfide isomerase-A1 (P4HB) gene
    Kajihara, Daniela
    Teixeira, Livia
    Laurindo, Francisco R.
    FREE RADICAL BIOLOGY AND MEDICINE, 2023, 208 : S21 - S21
  • [6] Electrospun CeO2-AgVO3/GO@PCL Composite Scaffolds: Structural, Mechanical, and Biological Characterizations for Advanced Biomedical Applications
    Hagar M. Mahdy
    Hanan Hendawy
    Yehia M. Abbas
    El-shazly M. Duraia
    BioNanoScience, 2025, 15 (3)
  • [7] In vitro evaluation of bioabsorbable poly(lactic acid) (PLA) and poly-4-hydroxybutyrate (P4HB) warp-knitted spacer fabric scaffolds for osteogenic differentiation
    Caronna, Flavia
    Limem, Skander
    Do, Ly Dang Khoa
    Ronan, William
    Dolan, Eimear B.
    BIOMEDICAL MATERIALS, 2025, 20 (02)
  • [8] Effect of poly(ethylene glycol) on drug delivery, antibacterial, biocompatible, physico-chemical and thermo-mechanical properties of PCL-chloramphenicol electrospun nanofiber scaffolds
    Arbade, Gajanan Kashinathrao
    Dongardive, Vikas
    Rath, Sangram K.
    Tripathi, Vidisha
    Patro, T. Umasankar
    INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2022, 71 (03) : 208 - 219
  • [9] Transcatheter Decellularized Tissue-Engineered Heart Valve (dTEHV) Grown on Polyglycolic Acid (PGA) Scaffold Coated with P4HB Shows Improved Functionality over 52 Weeks due to Polyether-Ether-Ketone (PEEK) Insert
    Bruder, Leon
    Spriestersbach, Hendrik
    Brakmann, Kerstin
    Stegner, Valentin
    Sigler, Matthias
    Berger, Felix
    Schmitt, Boris
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2018, 9 (04):
  • [10] RETRACTION: Transcatheter Decellularized Tissue-Engineered Heart Valve (dTEHV) Grown on Polyglycolic Acid ( PGA) Scaffold Coated with P4HB Shows Improved Functionality over 52 Weeks due to Polyether-Ether-Ketone (PEEK) Insert (Retraction of Vol 9, art no 64, 2018)
    Bruder, Leon
    Brakmann, Kerstin
    Stegner, Valentin
    Sigler, Matthias
    Berger, Felix
    Schmitt, Boris
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2019, 10 (01)