Interictal spike analysis of high-density EEG in patients with partial epilepsy

被引:57
|
作者
Wang, Gang [1 ,2 ]
Worrell, Gregory [3 ]
Yang, Lin [1 ,2 ]
Wilke, Christopher [1 ]
He, Bin [1 ,2 ]
机构
[1] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Ctr Neuroengn, Minneapolis, MN USA
[3] Mayo Clin, Dept Neurol, Rochester, MN USA
关键词
EEG source localization; Partial epilepsy; Localization error; Boundary element method; Interictal spike; RESOLUTION ELECTROMAGNETIC TOMOGRAPHY; CORTICAL CURRENT-DENSITY; REALISTIC HEAD MODEL; SOURCE LOCALIZATION; EPILEPTIFORM ACTIVITY; FOCAL EPILEPSY; BRAIN-LESIONS; DIPOLE LOCALIZATION; SCALP-EEG; MRI;
D O I
10.1016/j.clinph.2010.10.043
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: The aim of this study is to investigate the use of interictal spikes to localize epileptogenic brain from noninvasive scalp EEG recordings in patients with medically intractable epilepsy. Methods: Source reconstructions were performed using a high density electrode montage and a low density electrode montage by means of a distributed source modeling method. The source of interictal spike activity was localized using both a realistic geometry boundary element method (BEM) head model and 3-shell spherical head model. Results: In the analysis of 7 patients, the high density electrode montage was found to provide results more consistent with the suspected region of epileptogenic brain identified for surgical resection using intracranial EEG recordings and structural MRI lesions, as compared to the spatial low density electrode montage used in routine clinical practice. Furthermore, the realistic geometry BEM head model provided better source localization. Conclusions: Our results indicate the merits of using high density scalp EEG recordings and realistic geometry head modeling for source localization of interictal spikes in patients with partial epilepsy. Significance: The present results suggest further improvement of source localization accuracy of epileptogenic brain from interictal EEG recorded using high density scalp electrode montage and realistic geometry head models. (C) 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1098 / 1105
页数:8
相关论文
共 50 条
  • [1] Effects of inverse methods and spike phases on interictal high-density EEG source reconstruction
    van de Velden, Daniel
    Heide, Ev-Christin
    Bouter, Caroline
    Bucerius, Jan
    Riedel, Christian H.
    Focke, Niels K.
    CLINICAL NEUROPHYSIOLOGY, 2023, 156 : 4 - 13
  • [2] Automated interictal source localisation based on high-density EEG
    Vorderwuelbecke, Bernd J.
    Baroumand, Amir G.
    Spinelli, Laurent
    Seeck, Margitta
    van Mierlo, Pieter
    Vulliemoz, Serge
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2021, 92 : 244 - 251
  • [3] Impact of high-density EEG in presurgical evaluation for refractory epilepsy patients
    Li, Yi
    Fogarty, Adam
    Razavi, Babak
    Ardestani, Pooneh Memar
    Falco-Walter, Jessica
    Werbaneth, Katherine
    Graber, Kevin
    Meador, Kimford
    Fisher, Robert S.
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2022, 219
  • [4] Sleep and EEG interictal epileptiform abnormalities in partial epilepsy
    Gigli, GL
    Valente, M
    CLINICAL NEUROPHYSIOLOGY, 2000, 111 : S60 - S64
  • [5] Localizing hidden Interictal Epileptiform Discharges with simultaneous intracerebral and scalp high-density EEG recordings
    Zauli, Flavia Maria
    Del Vecchio, Maria
    Pigorini, Andrea
    Russo, Simone
    Massimini, Marcello
    Sartori, Ivana
    Cardinale, Francesco
    d'Orio, Piergiorgio
    Mikulan, Ezequiel
    JOURNAL OF NEUROSCIENCE METHODS, 2024, 409
  • [6] EEG-fMRI study of the interictal epileptic activity in patients with partial epilepsy
    Liu, Yonghong
    Yang, Tianhua
    Yang, Xuhong
    Liu, Ling
    Liao, Wei
    Lui, Su
    Huang, Xiaoqi
    Chen, Huafu
    Gong, Qiyong
    Zhou, Dong
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2008, 268 (1-2) : 117 - 123
  • [7] Detection of interictal epileptiform discharges in an extended scalp EEG array and high-density EEG-A prospective multicenter study
    Heers, Marcel
    Boettcher, Sebastian
    Kalina, Adam
    Katletz, Stefan
    Altenmueller, Dirk-Matthias
    Baroumand, Amir G.
    Strobbe, Gregor
    van Mierlo, Pieter
    von Oertzen, Tim J.
    Marusic, Petr
    Schulze-Bonhage, Andreas
    Beniczky, Sandor
    Duempelmann, Matthias
    EPILEPSIA, 2022, 63 (07) : 1619 - 1629
  • [8] Quantification and localization of EEG interictal spike activity in patients with surgically removed epileptogenic foci
    Coutin-Churchman, Pedro E.
    Wu, Joyce Y.
    Chen, Leo L. K.
    Shattuck, Kirk
    Dewar, Sandy
    Nuwer, Marc R.
    CLINICAL NEUROPHYSIOLOGY, 2012, 123 (03) : 471 - 485
  • [9] Interictal and ictal source localization for epilepsy surgery using high-density EEG with MEG: a prospective long-term study
    Plummer, Chris
    Vogrin, Simon J.
    Woods, William P.
    Murphy, Michael A.
    Cook, Mark J.
    Liley, David T. J.
    BRAIN, 2019, 142 : 932 - 951
  • [10] Targeted density electrode placement achieves high concordance with traditional high-density EEG for electrical source imaging in epilepsy
    Horrillo-Maysonnial, A.
    Avigdor, T.
    Abdallah, C.
    Mansilla, D.
    Thomas, J.
    von Ellenrieder, N.
    Royer, J.
    Bernhardt, B.
    Grova, C.
    Gotman, J.
    Frauscher, B.
    CLINICAL NEUROPHYSIOLOGY, 2023, 156 : 262 - 271