Non-Newtonian blood flow study in a model cavopulmonary vascular system

被引:9
作者
Chitra, K. [1 ]
Sundararajan, T. [2 ]
Vengadesan, S. [1 ]
Nithiarasu, P. [3 ]
机构
[1] Indian Inst Technol, Dept Appl Mech, Madras 600036, Tamil Nadu, India
[2] Indian Inst Technol, Dept Mech Engn, Madras 600036, Tamil Nadu, India
[3] Swansea Univ, Sch Engn, Swansea SA2 8PP, W Glam, Wales
基金
英国工程与自然科学研究理事会;
关键词
wall shear stress; haemodynamics; shear thinning; TCPC; finite element; recirculation zone; FONTAN OPERATIONS; FLUID-MECHANICS; FINITE-ELEMENT; ARTERIAL-WALL; CONNECTION; ATRIOPULMONARY; HEMODYNAMICS; SIMULATION; HEART;
D O I
10.1002/fld.2256
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A transient haemodynamic study in a model cavopulmonary vascular system has been carried out for a typical range of parameters using a finite element-based Navier-Stokes solver. The focus of this study is to investigate the influence of non-Newtonian behaviour of the blood on the haemodynamic quantities, such as wall shear stress (WSS) and flow pattern. The computational fluid dynamics (CFD) model is based on an artificial compressibility characteristic-based split (AC-CBS) scheme, which has been adopted to solve the Navier-Stokes equations in space-time domain. A power law model has been implemented to characterize the shear thinning nature of the blood depending on the local strain rate. Using the computational model, numerical investigations have been performed for Newtonian and non-Newtonian flows for different frequencies and input pulse forms. The haemodynamic quantities observed in total cavopulmonary connection (TCPC) for the above conditions suggest that there are considerable differences in average (about 25-40%) and peak (about 50%) WSS distributions, when the non-Newtonian behaviour of the blood is taken into account. The lower WSS levels observed for non-Newtonian cases point to the higher risk of lesion formation, especially at higher pulsation frequencies. A realistic pulse form is relatively safer than a sinusoidal pulse as it has more energy distributed in the higher harmonics, which results in higher average WSS values. The present study highlights the importance of including non-Newtonian shear thinning behaviour for modelling blood flow in the vicinity of repaired arterial connections. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:269 / 283
页数:15
相关论文
共 37 条
  • [1] Amodeo Antonio, 2004, Cardiol Young, V14 Suppl 3, P53
  • [2] [Anonymous], 2 INT BHURB C APPL S
  • [3] [Anonymous], THESIS IIT MADRAS
  • [4] [Anonymous], TRANSPORT PHENOMENA
  • [5] ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS
    CARO, CG
    FITZGERA.JM
    SCHROTER, RC
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046): : 109 - +
  • [6] Cebral J.R., 2002, PROC 14 US NATL C TH, P79
  • [7] CHAN W., 2007, Anziam Journal, V47, pC507
  • [8] An investigation of pulsatile flow in a model cavo-pulmonary vascular system
    Chitra, K.
    Vengadesan, S.
    Sundararajan, T.
    Nithiarasu, P.
    [J]. COMMUNICATIONS IN NUMERICAL METHODS IN ENGINEERING, 2009, 25 (11): : 1061 - 1083
  • [9] Cho YI., 1989, Effects of the non-Newtonian viscosity of blood on hemodynamics of diseased arterial flows, V15, P147
  • [10] DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682