Impact of a Risk Management Plan on Legionella Contamination of Dental Unit Water

被引:38
|
作者
Leoni, Erica [1 ]
Dallolio, Laura [1 ]
Stagni, Francesca [2 ]
Sanna, Tiziana [3 ]
D'Alessandro, Giovanni [2 ]
Piana, Gabriela [2 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Hyg Publ Hlth & Med Stat, I-40126 Bologna, Italy
[2] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Odontostomatol Sci, I-40125 Bologna, Italy
[3] Univ Bologna, Sch Hyg & Prevent Med, Dept Biomed & Neuromotor Sci, I-40126 Bologna, Italy
来源
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH | 2015年 / 12卷 / 03期
关键词
MICROBIAL BIOFILM FORMATION; PNEUMOPHILA CONTAMINATION; SYSTEMS; DISINFECTANTS; DECONTAMINATION; MULTICENTER; PREVALENCE; ANTIBODIES; INFECTION; SCHOOL;
D O I
10.3390/ijerph120302344
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 degrees C and 37 degrees C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.
引用
收藏
页码:2344 / 2358
页数:15
相关论文
共 50 条
  • [11] MICROBIAL CONTAMINATION OF DENTAL UNIT WATERLINES IN BUSHEHR, IRAN
    Dobaradaran, Sina
    Nabipour, Iraj
    Ramavandi, Bahman
    Zazouli, Mohammad Ali
    Tahmasebi, Rahim
    Ghaedi, Hossein
    Bahreini, Masoud
    Sirouss, Mehrandokht
    FRESENIUS ENVIRONMENTAL BULLETIN, 2014, 23 (04): : 1000 - 1005
  • [12] Monitoring Dental-Unit-Water-Line Output Water by Current In-office Test Kits
    Lal, Sham
    Singhrao, Sim K.
    Bricknell, Matt
    Pearce, Mark
    Morton, L. H. Glyn
    Ahmed, Waqar
    Crean, St John
    CURRENT MICROBIOLOGY, 2014, 69 (02) : 135 - 142
  • [13] Colonization of Dental Unit Waterlines by Helicobacter pylori: Risk of Exposure in Dental Practices
    Giacomuzzi, Monica
    Zotti, Carla M.
    Ditommaso, Savina
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (16)
  • [14] Cultural and Molecular Evidence of Legionella spp. Colonization in Dental Unit Waterlines: Which Is the Best Method for Risk Assessment?
    Ditommaso, Savina
    Giacomuzzi, Monica
    Ricciardi, Elisa
    Zotti, Carla M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2016, 13 (02):
  • [15] Bacterial contamination of dental unit waterlines
    Szymanska, Jolanta
    Sitkowska, Jolanta
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (05) : 3603 - 3611
  • [16] A review of biofilms and their role in microbial contamination of dental unit water systems (DUWS)
    Walker, JT
    Marsh, PD
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2004, 54 (2-3) : 87 - 98
  • [17] Disinfection methods of dental unit waterlines contamination: a systematic review
    Wu, Mengting
    Shi, Zhiwei
    Yu, Xuefen
    Xu, Yuedan
    Jin, Xinyang
    Zhang, Ling
    Fu, Baiping
    JOURNAL OF MEDICAL MICROBIOLOGY, 2022, 71 (06)
  • [18] An audit improves the quality of water within the dental unit water lines of general dental practices across the East of England
    Chate, R. A. C.
    BRITISH DENTAL JOURNAL, 2010, 209 (07) : 354 - 355
  • [19] Effectiveness and safety of low-concentrated ozonized water for the reduction of contamination in dental unit water lines
    Okubo, Keisuke
    Ito, Takashi
    Shiota, Yasuyoshi
    Kawata, Yusuke
    Yamamoto, Tadashi
    Takashiba, Shogo
    HELIYON, 2019, 5 (08)
  • [20] Hot water plumbing in residences and office buildings have distinctive risk of Legionella pneumophila contamination
    Donohue, Maura J.
    Mistry, Jatin H.
    Tucker, Nicole
    Vesper, Stephen J.
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2022, 245