Impact of a Risk Management Plan on Legionella Contamination of Dental Unit Water

被引:38
|
作者
Leoni, Erica [1 ]
Dallolio, Laura [1 ]
Stagni, Francesca [2 ]
Sanna, Tiziana [3 ]
D'Alessandro, Giovanni [2 ]
Piana, Gabriela [2 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Hyg Publ Hlth & Med Stat, I-40126 Bologna, Italy
[2] Univ Bologna, Dept Biomed & Neuromotor Sci, Unit Odontostomatol Sci, I-40125 Bologna, Italy
[3] Univ Bologna, Sch Hyg & Prevent Med, Dept Biomed & Neuromotor Sci, I-40126 Bologna, Italy
来源
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH | 2015年 / 12卷 / 03期
关键词
MICROBIAL BIOFILM FORMATION; PNEUMOPHILA CONTAMINATION; SYSTEMS; DISINFECTANTS; DECONTAMINATION; MULTICENTER; PREVALENCE; ANTIBODIES; INFECTION; SCHOOL;
D O I
10.3390/ijerph120302344
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 degrees C and 37 degrees C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.
引用
收藏
页码:2344 / 2358
页数:15
相关论文
共 50 条
  • [1] Impact of cleaning regimes on dental water unit contamination
    Abdallah, Soad A.
    Khalil, Ahmed I.
    JOURNAL OF WATER AND HEALTH, 2011, 9 (04) : 647 - 652
  • [2] Appraisal of microbial contamination of dental unit water systems and practices of general dental practitioners for risk reduction
    Lal, Bajrang
    Ravindra, Khaiwal
    Biswal, Manisha
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (33) : 33566 - 33572
  • [3] Control of microbial contamination in dental unit water systems using tetra-sodium EDTA
    Percival, R. S.
    Devine, D. A.
    Nattress, B.
    Kite, P.
    Marsh, P. D.
    JOURNAL OF APPLIED MICROBIOLOGY, 2009, 107 (04) : 1081 - 1088
  • [4] First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program
    Marino, Federica
    Mazzotta, Marta
    Pascale, Maria Rosaria
    Derelitto, Carlo
    Girolamini, Luna
    Cristino, Sandra
    JOURNAL OF ORAL MICROBIOLOGY, 2023, 15 (01)
  • [5] Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag+) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit Waterline
    Ditommaso, Savina
    Giacomuzzi, Monica
    Ricciardi, Elisa
    Zotti, Carla M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2016, 13 (07):
  • [6] The effect of disinfectant agents in eliminating the contamination of dental unit water
    Özcan, M
    Kulak, Y
    Kazazoglu, E
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (03) : 290 - 294
  • [7] Legionella spp. in dental unit waterlines
    Juraskova, Sedlata E.
    Sedlackova, H.
    Janska, J.
    Holy, O.
    Lalova, P.
    Matouskova, I
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2017, 118 (05): : 310 - 314
  • [8] Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing
    Alkhulaifi, Manal M.
    Alotaibi, Dalal H.
    Alajlan, Hisham
    Binshoail, Thekra
    SAUDI DENTAL JOURNAL, 2020, 32 (02) : 68 - 73
  • [9] Effect of Different Disinfection Protocols on Microbial and Biofilm Contamination of Dental Unit Waterlines in Community Dental Practices
    Dallolio, Laura
    Scuderi, Amalia
    Rini, Maria S.
    Valente, Sabrina
    Farruggia, Patrizia
    Sabattini, Maria A. Bucci
    Pasquinelli, Gianandrea
    Acacci, Anna
    Roncarati, Greta
    Leoni, Erica
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2014, 11 (02) : 2064 - 2076
  • [10] Persistent Legionella contamination of water faucets in a tertiary hospital in Japan
    Nakamura, Itaru
    Amemura-Maekawa, Junko
    Kura, Fumiaki
    Kobayashi, Takehito
    Sato, Akihiro
    Watanabe, Hidehiro
    Matsumoto, Tetsuya
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 93 : 300 - 304