Accuracy and Safety of High Pitch Computed Tomography Imaging in Young Children With Complex Congenital Heart Disease

被引:62
作者
Han, B. Kelly [1 ,2 ,4 ]
Lindberg, Jana [4 ]
Grant, Katharine [3 ]
Schwartz, Robert S. [4 ]
Lesser, John R. [4 ]
机构
[1] Childrens Heart Clin, Minneapolis, MN 55404 USA
[2] Childrens Hosp Minnesota, Minneapolis, MN USA
[3] Siemens Healthcare, Malvern, PA USA
[4] Minneapolis Heart Inst & Fdn, Minneapolis, MN USA
关键词
CT; COMPLICATIONS;
D O I
10.1016/j.amjcard.2011.01.065
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multidetector computed tomographic angiography defines anatomy in complex congenital heart disease, but radiation exposure and general anesthesia requirements limit its application. The aim of this study was to compare radiation exposure, anesthesia use, and diagnostic accuracy between standard-pitch, single-source computed tomography and high-pitch, dual-source computed tomography for image quality and risk in a clinical pediatric population. Consecutive computed tomographic scans were evaluated in patients aged <2 years with complex congenital heart disease. Two groups were compared on the basis of standard- versus high-pitch scans. High-pitch scans were further divided into variable pitch (2.25 to 3.0) and highest pitch (3.4) groups. Image quality, radiation exposure, anesthesia use, and diagnostic confidence and accuracy were determined. Sixty-one scans were reviewed (29 at standard pitch, 32 at high pitch). Body surface area, scan length, and indications were similar. The median dose-length product for standard-pitch scans was 66 mGy . cm (range 29 to 372) compared to 7 mGy . cm (range 3 to 50) in all high-pitch scans. The median dose-length product was 28 mGy . cm (range 8 to 50) for variable high-pitch scans and 5 mGy . cm (range 3 to 12) for the highest fixed-pitch scans. Diagnostic confidence was similar, although high-pitch scans had higher image noise and lower contrast-to-noise ratios. All high-pitch scans were performed under sedation with free breathing, and all standard-pitch scans required general anesthesia. Diagnostic accuracy was 100% in the 2 groups, with 17 standard-pitch and 16 high-pitch patients undergoing procedural validation. In conclusion, high-pitch, dual-source computed tomography provides excellent diagnostic accuracy and markedly reduces radiation dose, although image quality is mildly reduced. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:1541-1546)
引用
收藏
页码:1541 / 1546
页数:6
相关论文
共 12 条
  • [1] Radiation Risk From Pediatric Cardiac Catheterization Friendly Fire on Children With Congenital Heart Disease
    Andreassi, Maria Grazia
    [J]. CIRCULATION, 2009, 120 (19) : 1847 - 1849
  • [2] Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    Bacher, K
    Bogaert, E
    Lapere, R
    De Wolf, D
    Thierens, H
    [J]. CIRCULATION, 2005, 111 (01) : 83 - 89
  • [3] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [4] Risk factors for adverse events during cardiovascular magnetic resonance in congenital heart disease
    Dorfman, Adam L.
    Odegard, Kirsten C.
    Powell, Andrew J.
    Laussen, Peter C.
    Geva, Tal
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (05) : 793 - 798
  • [5] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [6] Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality
    Flohr, Thomas G.
    Leng, Shuai
    Yu, Lifeng
    Allmendinger, Thomas
    Bruder, Herbert
    Petersilka, Martin
    Eusemann, Christian D.
    Stierstorfer, Karl
    Schmidt, Bernhard
    McCollough, Cynthia H.
    [J]. MEDICAL PHYSICS, 2009, 36 (12) : 5641 - 5653
  • [7] Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates
    Hausleiter, J
    Meyer, T
    Hadamitzky, M
    Huber, E
    Zankl, M
    Martinoff, S
    Kastrati, A
    Schömig, A
    [J]. CIRCULATION, 2006, 113 (10) : 1305 - 1310
  • [8] Effective dose conversion factors in paediatric interventional cardiology
    Karambatsakidou, A.
    Sahlgren, B.
    Hansson, B.
    Lidegran, M.
    Fransson, A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (981) : 748 - 755
  • [9] Evaluation of a Radiation Dose Reduction Strategy for Pediatric Chest CT
    Kim, Jee-Eun
    Newman, Beverley
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1188 - 1193
  • [10] Vascular ultrasound imaging to study immediate postcatheterization vascular complications in children
    Kulkarni, Snehal
    Naidu, Renuka
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (03) : 450 - 455