Imaging of small spherical structures in CT: simulation study using measured point spread function

被引:12
作者
Ohkubo, Masaki [1 ]
Wada, Shinichi [1 ]
Kunii, Masayuki [1 ]
Matsumoto, Toru [2 ]
Nishizawa, Kanae [2 ]
机构
[1] Niigata Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Niigata 9518518, Japan
[2] Natl Inst Radiol Sci, Chiba 2638555, Japan
关键词
computed tomography (CT); point spread function (PSF); line spread function (LSF); section sensitivity profile (SSP); spatial resolution;
D O I
10.1007/s11517-007-0283-x
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Size and density measurements of objects undertaken using computed tomography (CT) are clinically significant for diagnosis. To evaluate the accuracy of these quantifications, we simulated three-dimensional (3D) CT image blurring; this involved the calculation of the convolution of the 3D object function with the measured 3D point spread function (PSF). We initially validated the simulation technique by performing a phantom experiment. Blurred computed images showed good 3D agreement with measured images of the phantom. We used this technique to compute the 3D blurred images from the object functions, in which functions are determined to have the shape of an ideal sphere of varying diameter and assume solitary pulmonary nodules with a uniform density. The accuracy of diameter and density measurements was determined. We conclude that the proposed simulation technique enables us to estimate the image blurring precisely of any 3D structure and to analyze clinical images quantitatively.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 24 条
[1]   Automated volumetry at CT colonography: A phantom study [J].
Blake, ME ;
Soto, JA ;
Hayes, RA ;
Ferrucci, JT .
ACADEMIC RADIOLOGY, 2005, 12 (05) :608-613
[2]   Determination of the presampled MTF in computed tomography [J].
Boone, JM .
MEDICAL PHYSICS, 2001, 28 (03) :356-360
[3]   Measurement of thickness and density of thin structures by computed tomography: A simulation study [J].
Dougherty, G ;
Newman, D .
MEDICAL PHYSICS, 1999, 26 (07) :1341-1348
[4]   Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383
[5]   Ultrasmall pulmonary opacities on multidetector-row high-resolution computed tomography - A prospective radiologic-pathologic examination [J].
Ishikawa, H ;
Koizumi, N ;
Morita, T ;
Tani, Y ;
Tsuchida, M ;
Umezu, H ;
Naito, M ;
Sasai, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (05) :621-625
[6]   Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT [J].
Jeong, YJ ;
Lee, KS ;
Jeong, SY ;
Chung, MJ ;
Shim, SS ;
Kim, H ;
Kwon, OJ ;
Kim, S .
RADIOLOGY, 2005, 237 (02) :675-683
[7]  
KALENDER WA, 2005, COMPUTED TOMOGRAPHY
[8]  
La Rivière PJ, 2002, PHYS MED BIOL, V47, P2797, DOI 10.1088/0031-9155/47/15/318
[9]   Anti-aliasing weighting functions for single-slice helical CT [J].
La Rivière, PJ ;
Pan, XC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :978-990
[10]   DERIVATION OF POINT SPREAD FUNCTION FROM LINE SPREAD FUNCTION [J].
MARCHAND, EW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1964, 54 (07) :915-&