R290 (propane) and R600a (isobutane) as natural refrigerants for residential heat pump water heaters

被引:90
|
作者
Nawaz, Kashif [1 ]
Shen, Bo [1 ]
Elatar, Ahmed [1 ]
Baxter, Van [1 ]
Abdelaziz, Omar [1 ]
机构
[1] Oak Ridge Natl Lab, Bldg Equipment Grp, Oak Ridge, TN 37831 USA
关键词
Heat pump; Water heater; Hydrocarbons; Alternative refrigerants; AIR-CONDITIONING SYSTEM; HYDROCARBON MIXTURES; ALTERNATIVE REFRIGERANTS; DOMESTIC REFRIGERATORS; RETROFIT ASSESSMENT; REPLACE HFC-134A; PERFORMANCE; CFC12; DROP;
D O I
10.1016/j.applthermaleng.2017.08.080
中图分类号
O414.1 [热力学];
学科分类号
摘要
Growing awareness of the potential environmental impacts of various refrigerants has led to the phase down of hydrofluorocarbon (HFC) refrigerants and to initiatives replacing HFCs with hydrocarbons or other environmentally friendlier fluids. This study evaluated the performance of R290 (propane) and R600a (isobutane) as substitutes for R134a (a HFC) for heat pump water heating (HPWH). A component-based model (calibrated against the experimental data) was used to predict the performance of the HPWH system. Key performance parameters such as unified energy factor, first hour rating, condenser discharge temperature, thermal stratification in the water tank, and total refrigerant charge were investigated. Analysis results suggest that both alternative refrigerants could provide comparable system performance to that of the baseline system containing R134a, with one caveat. As a drop-in alternative, R290 was found to be a better substitute for R134a, whereas R600a is expected to provide similar performance if the compressor size is increased to provide similar heating capacity. Significant reductions in system charge and lower condenser discharge temperatures were identified as additional benefits. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:870 / 883
页数:14
相关论文
共 50 条
  • [21] A molecular dynamics study of the condensation process in zeotropic R600a/R290 mixtures at condensing temperatures from 240 K and 360 K
    Hasan, Rakibul
    Alam, Sarwar
    Jeong, Ji Hwan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 161
  • [22] Comparative experimental analysis of direct-expansion solar-assisted heat pump water heaters using R134a and R290
    Kong, Xiangqiang
    Zhang, Maoyuan
    Yang, Yimeng
    Li, Ying
    Wang, Dechang
    SOLAR ENERGY, 2020, 203 : 187 - 196
  • [23] Research on the Thermophysical Properties and Cycle Performances of R1234yf/R290 and R1234yf/R600a
    Zhang, Nuochen
    Li, Biao
    Feng, Linghao
    Dai, Yuande
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2021, 42 (08)
  • [24] Solar-assisted auto-cascade heat pump cycle with zeotropic mixture R32/R290 for small water heaters
    Lv, Xiaolong
    Yan, Gang
    Yu, Jianlin
    RENEWABLE ENERGY, 2015, 76 : 167 - 172
  • [25] Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a
    Saravanakumar, R.
    Selladurai, V.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2014, 115 (01) : 933 - 940
  • [26] Thermodynamic analysis on a modified ejector expansion refrigeration cycle with zeotropic mixture (R290/R600a) for freezers
    Yan, Gang
    Bai, Tao
    Yu, Jianlin
    ENERGY, 2016, 95 : 144 - 154
  • [27] Theoretical investigation on the performance of an ejector enhanced refrigeration cycle using hydrocarbon mixture R290/R600a
    Chen, Qi
    Hwang, Yunho
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2020, 164
  • [28] Dynamic characteristics of a climate-adaptive radiant cooling and fresh air supply integrated system with zeotrope R290/R600a
    Zhu, Yutong
    Yin, Yonggao
    ENERGY CONVERSION AND MANAGEMENT, 2024, 317
  • [29] A thermodynamic analysis of a transcritical cycle with refrigerant mixture R32/R290 for a small heat pump water heater
    Yu, Jianlin
    Xu, Zong
    Tian, Gaolei
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2431 - 2436
  • [30] Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a, R1234yf, R290, R1270, R600a and R744
    Sanchez, D.
    Andreu-Nacher, A.
    Calleja-Anta, D.
    Llopis, R.
    Cabello, R.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 256