Free superficial circumflex iliac artery perforator flap with a single-pedicle bilobed design for pediatric multi-digit defect reconstruction

被引:9
作者
Li, Zhangcan [1 ]
Zheng, Dawei [1 ]
Zheng, Jian [1 ]
Qi, Weiya [1 ]
Qi, Qiang [1 ]
Liu, Yunyun [2 ]
机构
[1] Xuzhou Renci Hosp, Dept Hand Microsurg, 11 Yangshan Rd, Xuzhou 221004, Jiangsu, Peoples R China
[2] Xuzhou Maternal & Child Hlth Care Hosp, Dept Gynecol, Xuzhou 221009, Jiangsu, Peoples R China
关键词
Iliac artery; Perforator flap; Pediatrics; Reconstructive surgical procedures; Finger injuries;
D O I
10.1186/s13018-020-01733-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives This paper describes imaging and anatomical features, in order to assess the feasibility of superficial circumflex iliac artery perforator (SCIP) flap with a single-pedicle bilobed design for multi-digit skin and soft tissue reconstruction in pediatric patients. Methods A total of 7 pediatric patients who were being treated with free single-pedicle bilobed SCIP flap reconstruction for multi-digit defects were included in this study. The details of the clinical features were collected, and the following were successively analyzed: the preoperative computed tomographic angiography (CTA) and color Doppler sonography (CDS) examinations for flap design, the intraoperative anatomy for perforator vessel, defect reconstruction and interphalangeal range of motion (ROM) and tactile sense, pain sense, and two-point discrimination recovery results. Results CTA and CDS performed preoperatively could accurately and rapidly identify the position, location and course of the superficial circumflex iliac artery perforator. All wounds healed by the first follow-up and no complications occurred at the follow-up visit. All flaps survived, the patients achieved proximal interphalangeal joint (PIP) ranges of motions (ROM) from 80 to 100 degrees and distal interphalangeal joint (DIP) ROM from 65 to 80 degrees. The tactile sense and pain sense recovered, and average of the two-point discrimination scores was 9.3 mm (range 7-12 mm). The donor area was primarily sutured with a tidy scar in the underwear region. Conclusion CTA and CDS performed preoperatively are accurate and intuitive methods for assessing the location and course of SCIP. The SCIP flap is suitable for pediatric patients due to its small vessel caliber, specific functional and esthetic benefits. It can be designed in a lobulated fashion in order to repair two or more wounds during one surgery. We suggest that the free single-pedicle bilobed SCIP flap should be considered a good option choice for multi-digit defect reconstruction in pediatric patients in the clinic.
引用
收藏
页数:6
相关论文
共 23 条
  • [1] Evaluation of versatility of use of island first dorsal metacarpal artery flap in reconstruction of dorsal hand defects
    Ahmed, Mahfouz Shehata Ibrahim
    Ibrahim, Emad Salah
    Eltayeb, Hazem Ibrahim
    [J]. ASIAN JOURNAL OF SURGERY, 2019, 42 (01) : 197 - 202
  • [2] [Anonymous], PERFORATOR FLAPS ANA
  • [3] Local and Regional Flaps for Hand Coverage
    Biswas, Debdut
    Wysocki, Robert W.
    Fernandez, John J.
    Cohen, Mark S.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (05): : 992 - 1004
  • [4] THE PROXIMAL INSET THENAR FLAP FOR FINGERTIP RECONSTRUCTION
    DELLON, AL
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1983, 72 (05) : 698 - 702
  • [5] Superficial circumflex iliac artery perforator flap's imaging, anatomy and clinical applications in oral maxillofacial reconstruction
    He, Yue
    Jin, Shufang
    Tian, Zhuowei
    Fang, Zao
    Ma, Chunyue
    Tao, Xiaofeng
    Zhang, Yixin
    Qiu, Weiliu
    Zhang, Zhiyuan
    Zhang, Chenping
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (03) : 242 - 248
  • [6] FIBULA FREE FLAP - A NEW METHOD OF MANDIBLE RECONSTRUCTION
    HIDALGO, DA
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (01) : 71 - 79
  • [7] Modified Superficial Circumflex Iliac Artery Perforator Flap and Supermicrosurgery Technique for Lower Extremity Reconstruction A New Approach for Moderate-Sized Defects
    Hong, Joon Pio
    Sun, Sang Hoon
    Ben-Nakhi, Muneera
    [J]. ANNALS OF PLASTIC SURGERY, 2013, 71 (04) : 380 - 383
  • [8] Evolution of the free groin flap: The superficial circumflex iliac artery perforator flap
    Hsu, Wen-Ming
    Chao, Wai-Nang
    Yang, Cheng
    Fang, Chia-Liang
    Huang, Kuo-Feng
    Lin, Yu-San
    Lee, Tzong-Hann
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 119 (05) : 1491 - 1498
  • [9] The application of the rotation flap to the dorsum of the hand
    Hurren, JS
    Cormack, GC
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 2000, 53 (06): : 491 - 494
  • [10] SUPERMICROSURGICAL FREE SENSATE SUPERFICIAL CIRCUMFLEX ILIAC ARTERY PERFORATOR FLAP FOR RECONSTRUCTION OF A SOFT TISSUE DEFECT OF THE ANKLE IN A 1-YEAR-OLD CHILD
    Iida, Takuya
    Yamamoto, Takumi
    Yoshimatsu, Hidehiko
    Abe, Naho
    Tsuchiya, Masato
    Nemoto, Naho
    Watanabe, Shoji
    [J]. MICROSURGERY, 2016, 36 (03) : 254 - 258