Impact of different internal convection control strategies in a non-evacuated CPC collector performance

被引:23
作者
Horta, Pedro [1 ]
Henriques, J. C. C. [2 ]
Collares-Pereira, Manuel [3 ]
机构
[1] LNEG Lab Nacl Energia & Geol IP, P-1649038 Lisbon, Portugal
[2] Univ Tecn Lisboa, Inst Super Tecn, IDMEC, P-1049001 Lisbon, Portugal
[3] Univ Evora, Catedra BES Energias Renovaveis, P-7000890 Evora, Portugal
关键词
CPC collector; Convection losses; Medium temperature; COMPOUND PARABOLIC CONCENTRATORS; SOLAR-ENERGY COLLECTORS; BUOYANCY CONVECTION; NATURAL-CONVECTION; NUMERICAL-SOLUTION; EFFICIENCY TEST; SQUARE CAVITY; HEAT-TRANSFER; VORTICITY; BAFFLES;
D O I
10.1016/j.solener.2012.01.016
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Over the last decade the technological advances observed in solar collector materials, namely better spectrally selective absorber coatings and ultra clear glass covers, contribute to performance improvements and translate into higher operational temperature ranges with higher efficiency values. While the use of Evacuated Tube Collectors (ETCs) is becoming widespread in the thermal conversion of solar energy, non-evacuated solar collectors still hold advantages at manufacturing, reliability and/or cost levels, making them interesting and competitive for a large range of applications, in particularly, in temperature ranges up to 80 degrees C. However, these advantages have not prevented the major drawback of these collectors when compared to ETCs: thermal losses due to internal convection which prevent their general use in the range of operating temperatures up to 150 degrees C. Insulation, double glazing or selective coatings can be used in non-evacuated collectors to reduce heat losses. To prevent internal convection losses in these solar collectors, different control strategies have been studied, such as the adoption of different inert gases within the collector cavity, physical barriers reducing air flow velocities over the absorber or cover surfaces or the use of concentration. In the present article, an assessment of adopting such internal convection control strategies in a CPC collector is presented. Each of the presented strategies is assessed in terms of the resulting collector optical and thermal characterization parameters and yearly collector yield. For this purpose, an integrated tool allowing the design, optical and thermal characterization of CPC collectors was developed. The results obtained provide valuable guidelines for anyone wishing to implement any of these strategies in a new collector design. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1232 / 1244
页数:13
相关论文
共 52 条
  • [1] NATURAL-CONVECTION IN COMPOUND PARABOLIC CONCENTRATORS - FINITE-ELEMENT SOLUTION
    ABDELKHALIK, SI
    LI, HW
    RANDALL, KR
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1978, 100 (02): : 199 - 204
  • [2] Anderson John David, 1995, Computational Fluid Dynamics, V206
  • [3] [Anonymous], 2009, SOLTERM5 AN DES SIST
  • [4] [Anonymous], 2006, 1297522006 EN
  • [5] Becker E.B., 1981, Finite Elements, an Introduction, VI
  • [6] Aerogel and krypton insulated evacuated flat-plate collector for process heat production
    Benz, N
    Beikircher, T
    Aghazadeh, B
    [J]. SOLAR ENERGY, 1996, 58 (1-3) : 45 - 48
  • [7] High efficiency evacuated flat-plate solar collector for process steam production
    Benz, N
    Beikircher, T
    [J]. SOLAR ENERGY, 1999, 65 (02) : 111 - 118
  • [8] ECONOMIC OPTIMIZATION OF STATIONARY NONEVACUATED CPC SOLAR COLLECTORS
    CARVALHO, MJ
    COLLARESPEREIRA, M
    GORDON, JM
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1987, 109 (01): : 40 - 45
  • [9] TRUNCATION OF CPC SOLAR COLLECTORS AND ITS EFFECT ON ENERGY COLLECTION
    CARVALHO, MJ
    COLLARESPEREIRA, M
    GORDON, JM
    RABL, A
    [J]. SOLAR ENERGY, 1985, 35 (05) : 393 - 399
  • [10] Chaves J, 2002, THESIS TU LISBOA