Characterization of a new methylated β-cyclodextrin with a low degree of substitution by electrospray ionization mass spectrometry and liquid chromatography/mass spectrometry

被引:15
作者
Jacquet, R [1 ]
Elfakir, C [1 ]
Lafosse, M [1 ]
机构
[1] Univ Orleans, CNRS, UMR 6005, Inst Chim Organ & Analyt,FR 2708,UFR Sci, F-45067 Orleans, France
关键词
D O I
10.1002/rcm.2175
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new methylated beta-cyclodextrin (Me-beta-CD) with a low degree of substitution (DS) Was characterized by electrospray ionization mass spectrometry (ESI-MS) and liquid chromatography coupled with ESI-MS (LC/ESI-MS). For ESI-MS analyses, the composition of the infused sample solution was optimized in order to obtain only singly charged ammoniated CDs without fragmentation. The DS value (i.e. the number of methyl groups per glucopyranose unit) was found to be 0.7, which was in accordance with the values previously obtained by other methods. The LC/ESI-MS analysis, derived from a method using evaporative light scattering detection, allowed the study of the substitution isomers of each derivative and appears to be an easy and rapid tool for the accurate characterization of Me-beta-CD mixtures. Copyright (C) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:3097 / 3102
页数:6
相关论文
共 23 条
[1]   Quantitative determination of native and methylated cyclodextrins by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Bartsch, H ;
Konig, WA ;
Strassner, M ;
Hintze, U .
CARBOHYDRATE RESEARCH, 1996, 286 :41-53
[2]   Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry of dextran and dextrin derivatives [J].
Bashir, S ;
Derrick, PJ ;
Critchley, P ;
Gates, PJ ;
Staunton, J .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2003, 9 (01) :61-70
[3]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[4]   Advantages of evaporative light scattering detection for the purity control of commercial cyclodextrins [J].
Caron, I ;
Elfakir, C ;
Dreux, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (07) :1015-1035
[5]   Analysis of partially methylated cyclodextrins by subcritical fluid and liquid chromatography [J].
Caron, I ;
Salvador, A ;
Elfakir, C ;
Herbreteau, B ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 746 (01) :103-108
[6]   Correlation between the chromatographic properties of silica phenyl packing materials and the retention behaviour of methylated β-cyclodextrins [J].
Caron, I ;
Elfakir, C ;
Dreux, M .
CHROMATOGRAPHIA, 1998, 47 (7-8) :383-390
[7]  
Caron I, 1998, HRC-J HIGH RES CHROM, V21, P554
[8]   Cyclodextrins and their uses: a review [J].
Del Valle, EMM .
PROCESS BIOCHEMISTRY, 2004, 39 (09) :1033-1046
[9]   SFC with evaporative light-scattering SFC detection and atmospheric-pressure chemical-ionisation mass spectrometry for methylated glucoses and cyclodextrins analysis [J].
Herbreteau, B ;
Salvador, A ;
Lafosse, M ;
Dreux, M .
ANALUSIS, 1999, 27 (08) :706-712
[10]   CHARACTERIZATION OF CYCLODEXTRINS USING ION-EVAPORATION ATMOSPHERIC-PRESSURE IONIZATION TANDEM MASS-SPECTROMETRY [J].
HUANG, EC ;
HENION, JD .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (11) :467-471