Effect of Environment on Fatigue Failure of Controlled Memory Wire Nickel-Titanium Rotary Instruments

被引:75
作者
Shen, Ya [1 ]
Qian, Wei [1 ]
Abtin, Houman [1 ]
Gao, Yuan [2 ]
Haapasalo, Markus [1 ]
机构
[1] Univ British Columbia, Dept Oral Biol & Med Sci, Fac Dent, Vancouver, BC V5Z 1M9, Canada
[2] Sichuan Univ, State Key Lab Oral Dis, W China Coll & Hosp Stomatol, Chengdu 610064, Peoples R China
关键词
Controlled memory; EDTA; fatigue; nickel-titanium instrument; sodium hypochlorite; LOW-CYCLE FATIGUE; METALLURGICAL CHARACTERIZATION; SODIUM-HYPOCHLORITE; FRACTURE PROPERTIES; PART; RESISTANCE; CORROSION; ALLOY; BEHAVIOR; SURFACE;
D O I
10.1016/j.joen.2011.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study examined the fatigue behavior of 2 types of nickel-titanium (NiTi) instruments made from a novel controlled memory NiTi wire (CM wire) under various environment conditions. Methods: Three conventional superelastic NiTi instruments of Pro File (Dentsply Maillefer, Ballaigues, Switzerland), Typhoon (Clinician's Choice Dental Products, New Milford, CT), and DS-SS0250425NEYY (Clinician's Choice Dental Products) and 2 new CM wire instruments of Typhoon CM and DS-SS0250425NEYY CM were subjected to rotational bending at the curvature of 35 in air, deionized water, 17% EDTA, or deionized water after immersion in 6% sodium hypochlorite for 25 minutes, and the number of revolutions of fracture (Ni) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. The crack-initiation sites and the percentage of dimple area to the whole fracture cross-section were noted. Results: Two new CM Wire instruments yielded an improvement of >4 to 9 times in Nf than conventional NiTi files with the same design under various environments (P <.05). The fatigue life of 3 conventional superelastic NiTi instruments was similar under various environments, whereas the Nf of 2 new CM Wire instruments was significantly longer in liquid media than in air (P <.05). The vast majority of CM instruments showed multiple crack origins, whereas most instruments made from conventional NiTi wire had one crack origin. The values of the area fraction occupied by the dimple region were significantly smaller on CM NiTi instruments than in conventional NiTi instruments under various environments (P <.05). Conclusions: Within the limitations of this study, the type of NiTi metal alloy (CM files vs conventional superelastic NiTi files) influences the cyclic fatigue resistance under various environments. The fatigue life of CM instruments is longer in liquid media than in air. (JI Endod 2012;38:376-380)
引用
收藏
页码:376 / 380
页数:5
相关论文
共 38 条
  • [1] Metallurgical Characterization of a New Nickel-Titanium Wire for Rotary Endodontic Instruments
    Alapati, Satish B.
    Brantley, William A.
    Iijima, Masahiro
    Clark, William A. T.
    Kovarik, Libor
    Buie, Caesar
    Liu, Jie
    Ben Johnson, William
    [J]. JOURNAL OF ENDODONTICS, 2009, 35 (11) : 1589 - 1593
  • [2] Angelini E, 2002, INTEGRATED BIOMATERIALS SCIENCE, P297, DOI 10.1007/0-306-47583-9_7
  • [3] BAUMGARTNER JC, 1987, J ENDODONT, V13, P147
  • [4] Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments
    Berutti, E.
    Angelini, E.
    Rigolone, M.
    Migliaretti, G.
    Pasqualini, D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (09) : 693 - 699
  • [5] Pitting corrosion resistance of nickel-titanium rotary instruments with different surface treatments in seventeen percent ethylenediaminetetraacetic acid and sodium chloride solutions
    Bonaccorso, Antonio
    Tripi, Teresa Roberta
    Rondelli, Gianni
    Condorelli, Guglielmo Guido
    Cantatore, Giuseppe
    Schaefer, Edgar
    [J]. JOURNAL OF ENDODONTICS, 2008, 34 (02) : 208 - 211
  • [6] Fatigue testing of a NiTi rotary instrument. Part 2: fractographic analysis
    Cheung, G. S. P.
    Darvell, B. W.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (08) : 619 - 625
  • [7] Effect of environment on low-cycle fatigue of a nickel-titanium instrument
    Cheung, Gary S. P.
    Shen, Ya
    Darvell, Brian W.
    [J]. JOURNAL OF ENDODONTICS, 2007, 33 (12) : 1433 - 1437
  • [8] Improvement of the fatigue resistance of NiTi endodontic files by surface and bulk modifications
    Condorelli, G. G.
    Bonaccorso, A.
    Smecca, E.
    Schaefer, E.
    Cantatore, G.
    Tripi, T. R.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (10) : 866 - 873
  • [9] Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions
    Darabara, M
    Bourithis, L
    Zinelis, S
    Papadimitriou, GD
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (10) : 705 - 710
  • [10] Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique
    Gambarini, G.
    Plotino, G.
    Grande, N. M.
    Al-Sudani, D.
    De Luca, M.
    Testarelli, L.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (04) : 337 - 341