Accurate work-rate measurements during in vivo MRS studies of exercising human quadriceps
被引:42
作者:
Layec, Gwenael
论文数: 0引用数: 0
h-index: 0
机构:
Fac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Layec, Gwenael
[1
]
Bringard, Aurelien
论文数: 0引用数: 0
h-index: 0
机构:
UFR STAPS, Fac Sci Sport, EA 2991, F-34090 Montpellier, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Bringard, Aurelien
[2
]
Vilmen, Christophe
论文数: 0引用数: 0
h-index: 0
机构:
Fac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Vilmen, Christophe
[1
]
Micallef, Jean-Paul
论文数: 0引用数: 0
h-index: 0
机构:
UFR STAPS, Fac Sci Sport, EA 2991, F-34090 Montpellier, France
INSERM, ADR 08, F-34197 Montpellier 5, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Micallef, Jean-Paul
[2
,3
]
Le Fur, Yann
论文数: 0引用数: 0
h-index: 0
机构:
Fac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Le Fur, Yann
[1
]
Perrey, Stephane
论文数: 0引用数: 0
h-index: 0
机构:
UFR STAPS, Fac Sci Sport, EA 2991, F-34090 Montpellier, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Perrey, Stephane
[2
]
Cozzone, Patrick J.
论文数: 0引用数: 0
h-index: 0
机构:
Fac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Cozzone, Patrick J.
[1
]
Bendahan, David
论文数: 0引用数: 0
h-index: 0
机构:
Fac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, FranceFac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
Bendahan, David
[1
]
机构:
[1] Fac Med Marseille, CNRS, UMR 6612, Ctr Resonance Magnet Biol & Med, F-13005 Marseille, France
[2] UFR STAPS, Fac Sci Sport, EA 2991, F-34090 Montpellier, France
magnetic resonance spectroscopy;
ergometer;
exercise;
knee extension;
D O I:
10.1007/s10334-008-0117-3
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Introduction Given that we have reached a point in the field of muscle energetics where absolute measurements are warranted to take the area forward, we designed an ergometer, including two force and two displacement transducers, allowing dynamic and isometric knee extension within a MR system and accurate measurements of power output. Methods On the basis of repeated measurements, the force and displacement transducers accuracy was 1% for values ranging from 0 to 394 N and 4% for values ranging from 0 to 20 cm. In addition, measurements were not affected by magnetic field. MRS experiments in exercising muscle were conducted in eight subjects. They performed two standardized dynamic alternate leg extension exercises (25 and 35% of MVC) while the corresponding metabolic changes were measured using (31)P-MRS. Results The mean power output produced during both exercises were 63 +/- 16 and 81 +/- 15 W while the eccentric work was reduced i.e. 12 +/- 14 and 21 +/- 6 W for the moderate and heavy exercise respectively. The corresponding metabolic changes were significant with a 20-40% PCr depletion and an end of exercise pH ranging from 0.02 to 0.70 pH units. Conclusion Overall, the present ergometer allows quadriceps exercise in a MR system and should be useful for future metabolic studies for which reliable and absolute quantification of power output is warranted.