Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography

被引:18
作者
Melese, Ephrem K. [1 ]
Chan, Jeffrey D. [2 ]
Blieden, Lauren S. [1 ,3 ]
Chuang, Alice Z. [3 ]
Baker, Laura A. [1 ]
Bell, Nicholas P. [1 ,3 ]
Feldman, Robert M. [1 ,3 ]
机构
[1] Robert Cizik Eye Clin, 6400 Fannin St,Suite 1800, Houston, TX 77030 USA
[2] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Coll Engn, Berkeley, CA 94720 USA
[3] Univ Texas Hlth Sci Ctr Houston UTHlth, McGovern Med Sch, Ruiz Dept Ophthalmol & Visual Sci, Houston, TX USA
基金
美国国家卫生研究院;
关键词
LASER PERIPHERAL IRIDOTOMY; PRIMARY ANGLE-CLOSURE; INTRAOCULAR-PRESSURE REDUCTION; ULTRASOUND BIOMICROSCOPY; PHACOEMULSIFICATION; EYES; PERFORMANCE; GONIOSCOPY; CATARACT; IMAGES;
D O I
10.1016/j.ajo.2016.06.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine and validate thresholds of anterior chamber angle (ACA) parameters in discriminating open-vs narrow-angle eyes using images from dedicated anterior segment optical coherence tomography (DASOCT). DESIGN: Reliability analysis. METHODS: Eyes imaged by DASOCT and examined with gonioscopy were reviewed. By gonioscopy, eyes were classified as narrow if posterior trabecular meshwork was not visible and open if the angle was open to scleral spur and beyond. Imaging was performed in the dark with the CASIA SS-1000 (Tomey, Nagoya, Japan). ACA parameters angle opening distance (AOD), trabecular-iris space area (TISA), trabecular-iris circumference volume (TICV), length of iridotrabecular contact (ITC), and extent and area of ITC were calculated. AOD, TISA, and TICV were measured at both 500 mu m and 750 mu m from the scleral spur landmark. Study eyes were randomly divided into training and testing sets. Thresholds were calculated from the training set. Sensitivity, specificity, and agreement were then calculated against the clinical classification using the testing set. RESULTS: One hundred and eighty-nine eyes (111 open, 78 narrow, including 8 borderline angles) were included. Using the threshold determined in the training set on the testing set, 9 of 24 ACA parameters had no misclassification of narrow-angle eyes as open (sensitivity = 1.0). Of 9 parameters, the specificity was > 0.79. The highest kappa values (kappa = 0.91) was AOD750 inferiorly at 0.31 mm threshold, followed by both TICV500 at 1.92 mu L and TICV750 at 4.00 mu L with kappa = 0.86. CONCLUSION: The parameters with the best discriminative ability for detecting narrow angles were AOD750 inferiorly, TICV500, and TICV750. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:208 / 217
页数:10
相关论文
共 50 条
  • [21] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    [J]. WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [22] Deconstructing the mechanisms of angle closure with anterior segment optical coherence tomography
    Liu, Lance
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07) : 614 - 622
  • [23] Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters
    Xu, Benjamin Y.
    Penteado, Rafaella C.
    Weinreb, Robert N.
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (01) : 16 - 21
  • [24] Anterior Segment Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Mature Cataracts
    Mansouri, Mohammadreza
    Ramezani, Farshid
    Moghimi, Sasan
    Tabatabaie, Ali
    Abdi, Fatemeh
    He, Mingguang
    Lin, Shan C.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7403 - 7409
  • [25] Analysis of Anterior Segment Dynamics Using Anterior Segment Optical Coherence Tomography Before and After Laser Peripheral Iridotomy
    Zheng, Ce
    Guzman, Celeste P.
    Cheung, Carol Y.
    He, Yingke
    Friedman, David S.
    Ong, Sim-Heng
    Narayanaswamy, Arun K.
    Chew, Paul T.
    Perera, Shamira A.
    Aung, Tin
    [J]. JAMA OPHTHALMOLOGY, 2013, 131 (01) : 44 - 49
  • [26] Comparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography
    Leung, C. K.
    Palmiero, P-M
    Weinreb, R. N.
    Li, H.
    Sbeity, Z.
    Dorairaj, S.
    Leung, D.
    Liu, S.
    Liebmann, J. M.
    Congdon, N.
    Lam, D. S.
    Ritch, R.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (09) : 1184 - 1189
  • [27] Anterior Segment Optical Coherence Tomography as a Screening Tool for the Assessment of the Anterior Segment Angle
    Pekmezci, Melike
    Porco, Travis C.
    Lin, Shan C.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (04) : 389 - 398
  • [28] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    [J]. EYE, 2010, 24 (04) : 578 - 587
  • [29] The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography
    Nakamine, Sakari
    Sakai, Hiroshi
    Arakaki, Yoshikuni
    Yonahara, Michiko
    Kaiya, Tadayoshi
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (01) : 48 - 53
  • [30] Anterior Segment Optical Coherence Tomography Characteristics in an Asian Population
    Sihota, Ramanjit
    Vashisht, Praveen
    Sharma, Ajay
    Chakraborty, Swapna
    Gupta, Viney
    Pandey, Ravindra M.
    [J]. JOURNAL OF GLAUCOMA, 2012, 21 (03) : 180 - 185