Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography

被引:17
作者
Melese, Ephrem K. [1 ]
Chan, Jeffrey D. [2 ]
Blieden, Lauren S. [1 ,3 ]
Chuang, Alice Z. [3 ]
Baker, Laura A. [1 ]
Bell, Nicholas P. [1 ,3 ]
Feldman, Robert M. [1 ,3 ]
机构
[1] Robert Cizik Eye Clin, 6400 Fannin St,Suite 1800, Houston, TX 77030 USA
[2] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Coll Engn, Berkeley, CA 94720 USA
[3] Univ Texas Hlth Sci Ctr Houston UTHlth, McGovern Med Sch, Ruiz Dept Ophthalmol & Visual Sci, Houston, TX USA
基金
美国国家卫生研究院;
关键词
LASER PERIPHERAL IRIDOTOMY; PRIMARY ANGLE-CLOSURE; INTRAOCULAR-PRESSURE REDUCTION; ULTRASOUND BIOMICROSCOPY; PHACOEMULSIFICATION; EYES; PERFORMANCE; GONIOSCOPY; CATARACT; IMAGES;
D O I
10.1016/j.ajo.2016.06.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine and validate thresholds of anterior chamber angle (ACA) parameters in discriminating open-vs narrow-angle eyes using images from dedicated anterior segment optical coherence tomography (DASOCT). DESIGN: Reliability analysis. METHODS: Eyes imaged by DASOCT and examined with gonioscopy were reviewed. By gonioscopy, eyes were classified as narrow if posterior trabecular meshwork was not visible and open if the angle was open to scleral spur and beyond. Imaging was performed in the dark with the CASIA SS-1000 (Tomey, Nagoya, Japan). ACA parameters angle opening distance (AOD), trabecular-iris space area (TISA), trabecular-iris circumference volume (TICV), length of iridotrabecular contact (ITC), and extent and area of ITC were calculated. AOD, TISA, and TICV were measured at both 500 mu m and 750 mu m from the scleral spur landmark. Study eyes were randomly divided into training and testing sets. Thresholds were calculated from the training set. Sensitivity, specificity, and agreement were then calculated against the clinical classification using the testing set. RESULTS: One hundred and eighty-nine eyes (111 open, 78 narrow, including 8 borderline angles) were included. Using the threshold determined in the training set on the testing set, 9 of 24 ACA parameters had no misclassification of narrow-angle eyes as open (sensitivity = 1.0). Of 9 parameters, the specificity was > 0.79. The highest kappa values (kappa = 0.91) was AOD750 inferiorly at 0.31 mm threshold, followed by both TICV500 at 1.92 mu L and TICV750 at 4.00 mu L with kappa = 0.86. CONCLUSION: The parameters with the best discriminative ability for detecting narrow angles were AOD750 inferiorly, TICV500, and TICV750. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:208 / 217
页数:10
相关论文
共 50 条
  • [1] Measurement of early changes in anterior chamber morphology after cataract extraction measured by anterior segment optical coherence tomography
    Kasai, Kozue
    Takahashi, Genichiro
    Kumegawa, Koichi
    Dogru, Murat
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (10) : 1751 - 1756
  • [2] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [3] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [4] Evaluation of Anterior Segment Parameters in Pseudoexfoliation Disease Using Anterior Segment Optical Coherence Tomography
    Mohammadi, Massood
    Johari, Mohammadkarim
    Eslami, Yadollah
    Moghimi, Sasan
    Zarei, Reza
    Fakhraie, Ghasem
    Safizadeh, Mona
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 234 : 199 - 204
  • [5] Quantitative evaluation of anterior chamber parameters using anterior segment optical coherence tomography in primary angle closure mechanisms
    Shabana, Noor
    Aquino, Maria C. D.
    See, Jovina
    Ce, Zheng
    Tan, Anna M.
    Nolan, Winifred P.
    Hitchings, Roger
    Young, Stephanie M.
    Loon, Seng Chee
    Sng, Chelvin C.
    Wong, Wanling
    Chew, Paul T. K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (08) : 792 - 801
  • [6] Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography
    Kim, Dong Y.
    Sung, Kyung R.
    Kang, Sung Y.
    Cho, Jung W.
    Lee, Kyoung S.
    Park, Seong B.
    Kim, Soon T.
    Kook, Michael S.
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 435 - 441
  • [7] Application of anterior segment optical coherence tomography in glaucoma
    Sharma, Reetika
    Sharma, Ajay
    Arora, Tarun
    Sharma, Sourabh
    Sobti, Amit
    Jha, Bhaskar
    Chaturvedi, Neha
    Dada, Tanuj
    SURVEY OF OPHTHALMOLOGY, 2014, 59 (03) : 311 - 327
  • [8] Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography
    Khor, Wei-Boon
    Sakata, Lisandro M.
    Friedman, David S.
    Narayanaswamy, Arun
    Lavanya, Raghavan
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 365 - 368
  • [9] Assessment of Anterior Chamber by Ultrasound Biomicroscopy and Anterior Segment Optical Coherence Tomography in Patients with Inflammatory Glaucoma
    Qian, Yiyong
    Liu, Lin
    Shi, Yuehui
    Wang, Minli
    Li, Min
    Zou, Jun
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (12) : 5950 - 5956
  • [10] Anterior Segment Optical Coherence Tomography
    Jancevski, Maria
    Foster, C. Stephen
    SEMINARS IN OPHTHALMOLOGY, 2010, 25 (5-6) : 317 - 323