Macular versus nerve fibre layer versus optic nerve head imaging for diagnosing glaucoma at different stages of the disease: Multicenter Italian Glaucoma Imaging Study

被引:15
作者
Michelessi, Manuele [1 ]
Riva, Ivano [1 ]
Martini, Enrico [2 ]
Figus, Michele [3 ]
Frezzotti, Paolo [4 ]
Agnifili, Luca [5 ]
Manni, Gianluca [1 ,6 ]
Quaranta, Luciano [7 ]
Miglior, Stefano [8 ]
Posarelli, Chiara [3 ]
Fazio, Stefano [4 ]
Oddone, Francesco [1 ]
机构
[1] IRCCS Fdn Bietti, Via Livenza 3, I-00198 Rome, Italy
[2] Sassuolo Hosp, UO Ophthalmol, Sassuolo, Italy
[3] Univ Pisa, Dept Surg Med Mol Pathol & Crit Area, Pisa, Italy
[4] Univ Siena, Dept Med Surg & Neurosci, Siena, Italy
[5] Univ G dAnnunzio, Ophthalmol Clin, Dept Med & Aging Sci, Chieti, Italy
[6] Univ Roma Tor Vergata, DSCMT, Rome, Italy
[7] Univ Brescia, Dept Med & Surg Specialties Radiol Sci & Publ Hlt, Brescia, Italy
[8] Univ Bicocca Milan, Dept Ophthalmol, Milan, Italy
关键词
diagnostic accuracy; glaucoma; macular analysis; minimum rim width; optical coherence tomography; COHERENCE TOMOGRAPHY; THICKNESS; ACCURACY; SEGMENTATION; DAMAGE; DISC;
D O I
10.1111/aos.13930
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the diagnostic accuracy of minimum rim width (MRW), peripapillary retinal nerve fibre layer (pRNFL) and multilayered macular analysis by Spectralis SD-OCT (Heidelberg Engineering, Germany) in discriminating perimetric glaucoma at different stages of the disease from healthy eyes. Methods In this multicentre, prospective, evaluation of diagnostic tests study, multilayered macular analysis and MRW and pRNFL were obtained from one eye of 197 glaucoma (76 early, 68 moderate and 53 advanced) and of 83 healthy controls from the Multicenter Italian Glaucoma Imaging Study (MIGIS). The reference standard for classifying eyes as glaucomatous and for staging the disease was the visual field. The main outcome measures were area under the ROC curve (AUC) and sensitivity at fixed specificity (95%). Results Average MRW and average pRNFL showed the highest and similar diagnostic accuracy in both the whole study population (AUC 0.968 and 0.939) and early glaucoma (AUC 0.956 and 0.929). Among the macular parameters, the three innermost retinal layers combined as the Ganglion Cell Complex provided the highest diagnostic accuracy (AUC 0.931) in the whole population, which was statistically similar to that of average pRNFL but inferior to that of average MRW. Compared to both average MRW and pRNFL, all macular parameters showed statistically significant lower accuracy in early glaucoma, but accuracy in moderate and advanced glaucoma showed no statistically significant differences among three protocols. Conclusion The diagnostic accuracy of MRW, pRNFL and macular analysis by Spectralis SD-OCT is overall good. MRW and pRNFL analysis performs statistically and clinically better than macular analysis to discriminate early glaucoma from healthy eyes.
引用
收藏
页码:E207 / E215
页数:9
相关论文
共 27 条
[1]   Ganglion Cell-Inner Plexiform Layer Thickness of High Definition Optical Coherence Tomography in Perimetric and Preperimetric Glaucoma [J].
Begum, Viquar U. ;
Addepalli, Uday K. ;
Yadav, Ravi K. ;
Shankar, Kalmuri ;
Senthil, Sirisha ;
Garudadri, Chandra S. ;
Rao, Harsha L. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (08) :4768-4775
[2]   Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography-Derived Neuroretinal Rim Parameter [J].
Chauhan, Balwantray C. ;
O'Leary, Neil ;
AlMobarak, Faisal A. ;
Reis, Alexandre S. C. ;
Yang, Hongli ;
Sharpe, Glen P. ;
Hutchison, Donna M. ;
Nicolela, Marcelo T. ;
Burgoyne, Claude F. .
OPHTHALMOLOGY, 2013, 120 (03) :535-543
[3]   Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[4]   TOPOGRAPHY OF GANGLION-CELLS IN HUMAN RETINA [J].
CURCIO, CA ;
ALLEN, KA .
JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 300 (01) :5-25
[5]  
Curcio CA, 2013, INVEST OPHTH VIS SCI, V52, P3943
[6]   Enhanced Structure-Function Relationship in Glaucoma With an Anatomically and Geometrically Accurate Neuroretinal Rim Measurement [J].
Danthurebandara, Vishva M. ;
Sharpe, Glen P. ;
Hutchison, Donna M. ;
Denniss, Jonathan ;
Nicolela, Marcelo T. ;
McKendrick, Allison M. ;
Turpin, Andrew ;
Chauhan, Balwantray C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (01) :98-105
[7]   Sources of bias in studies of optic disc and retinal nerve fibre layer morphology [J].
Garway-Heath, DF ;
Hitchings, RA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (09) :986-986
[8]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[9]  
Hodapp E., 1993, ELSEVIER HLTH SCI
[10]   Glaucomatous damage of the macula [J].
Hood, Donald C. ;
Raza, Ali S. ;
de Moraes, Carlos Gustavo V. ;
Liebmann, Jeffrey M. ;
Ritch, Robert .
PROGRESS IN RETINAL AND EYE RESEARCH, 2013, 32 :1-21