Effects of Liquid Cooling Garments on Recovery and Performance Time in Individuals Performing Strenuous Work Wearing a Firefighter Ensemble

被引:64
作者
Kim, Jung-Hyun [1 ]
Coca, Aitor [1 ]
Williams, W. Jon [1 ]
Roberge, Raymond J. [1 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, CDC, Pittsburgh, PA 15236 USA
关键词
core temperature; firefighter ensembles; heat stress; liquid cooling garments; UNCOMPENSABLE HEAT-STRESS; WARM ENVIRONMENTS; AEROBIC FITNESS; EXERCISE; TOLERANCE; BODY; STRAIN; TEMPERATURE; HYDRATION; AIR;
D O I
10.1080/15459624.2011.584840
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the effects of body cooling using liquid cooling garments (LCG) on performance time (PT) and recovery in individuals wearing a fully equipped prototype firefighter ensemble (PFE) incorporating a self-contained breathing apparatus (SCBA). Six healthy male participants (three firefighters and three non-firefighters) completed six experimental sessions in an environmental chamber (35 degrees C, 50% relative humidity), consisting of three stages of 15 min exercise at 75% VO(2max), and 10 min rest following each exercise stage. During each session, one of the following six conditions was administered in a randomized order: control (no cooling, CON); air ventilation of exhaust SCBA gases rerouted into the PFE (AV): top cooling garment (TCG); TCG combined with AV (TCG+AV); a shortened whole body cooling garment (SCG), and SCG combined with AV (SCG+AV). Results showed that total PT completed was longer tinder SCG and SCG+AV compared with CON, AV, TCG, and TCG+AV (p < 0.01). Magnitude of core temperature (T(c)) elevation was significantly decreased when SCG was utilized (p < 0.01), and heart rate recovery rate (10 min) was enhanced under SCG, SCG+AV, TCG, and TCG+AV compared with CON (p < 0.05). Estimated E(sw) rate (kg.h(-1)) was the greatest in CON, 1.62 (0.37), and the least in SCG+AV 0.98 (0.44): (descending order: CON > AV > TCG = TCG+AV > SCG > SCG+AV) without a statistical difference between the conditions (p < 0.05). Results of the present study suggest that the application of LCG underneath the PFE significantly improves the recovery during a short period of rest and prolongs performance time in subsequent bouts of exercise. LCG also appears to be an effective method for body cooling that promotes heat dissipation during uncompensable heat stress.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 26 条
[1]   A practical cooling strategy for reducing the physiological strain associated with firefighting activity in the heat [J].
Barr, D. ;
Gregson, W. ;
Sutton, L. ;
Reilly, T. .
ERGONOMICS, 2009, 52 (04) :413-420
[2]   The thermal ergonomics of firefighting reviewed [J].
Barr, David ;
Gregson, Warren ;
Reilly, Thomas .
APPLIED ERGONOMICS, 2010, 41 (01) :161-172
[3]   Intermittent microclimate cooling during exercise-heat stress in US army chemical protective clothing [J].
Cadarette, BS ;
Cheuvront, SN ;
Kolka, MA ;
Stephenson, LA ;
Montain, SJ ;
Sawka, MN .
ERGONOMICS, 2006, 49 (02) :209-219
[4]   Strategies to combat heat strain during and after firefighting [J].
Carter, J. M. ;
Rayson, M. P. ;
Wilkinson, D. M. ;
Richmond, V. ;
Blacker, S. .
JOURNAL OF THERMAL BIOLOGY, 2007, 32 (02) :109-116
[5]   Effectiveness of rest pauses and cooling in alleviation of heat stress during simulated fire-fighting activity [J].
Carter, JB ;
Banister, EW ;
Morrison, JB .
ERGONOMICS, 1999, 42 (02) :299-313
[6]   Heat acclimation, aerobic fitness, and hydration effects on tolerance during uncompensable heat stress [J].
Cheung, SS ;
McLellan, TM .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (05) :1731-1739
[7]   Physiological and subjective responses to cooling devices on firefighting protective clothing [J].
Chou, Chinmei ;
Tochihara, Yutaka ;
Kim, Taegyou .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (02) :369-374
[8]   Ergonomic comparison of a chem/bio prototype firefighter ensemble and a standard ensemble [J].
Coca, Aitor ;
Roberge, R. ;
Shepherd, A. ;
Powell, J. B. ;
Stull, J. O. ;
Williams, W. J. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (02) :351-359
[9]   Design and control optimization of microclimate liquid cooling systems underneath protective clothing [J].
Flouris, AD ;
Cheung, SS .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (03) :359-372
[10]  
GLEDHILL N, 1992, CAN J SPORT SCI, V17, P207