Stand-Alone Operation of Distributed Generation Systems With Improved Harmonic Elimination Scheme

被引:7
作者
Khan, Mohammed Ali [1 ]
Haque, Ahteshamul [1 ]
Kurukuru, V. S. Bharath [1 ]
Wang, Huai [2 ]
Blaabjerg, Frede [2 ]
机构
[1] Jamia Millia Islamia, Adv Power Elect Res Lab, Dept Elect Engn, New Delhi 110025, India
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Voltage control; Harmonic analysis; Switches; Inverters; Pulse width modulation; Power system harmonics; Load shedding; Distributed generation (DG); pulse width modulation (PWM); selective harmonic elimination (SHE); stand-alone (SA) mode; total harmonic distortion (THD); voltage regulation; MULTILEVEL INVERTER;
D O I
10.1109/JESTPE.2021.3084737
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Improvement in the efficiency of distributed generation (DG) inverters is a concern and challenge for researchers across the globe. To address the concern, an inverter control technique is developed. Inverters have issues with voltage regulation and harmonics when operating in the grid-connected (GC) and stand-alone (SA) mode. This article proposes a control strategy capable of operating DGs in both SA and GC environments. The GC operation of the inverter is achieved by the current control mode, and the SA control features a voltage control loop capable of overcoming the drawbacks due to load shedding or load switching. Besides, the harmonics due to various conditions of transition and load switching are eliminated by adapting a harmonic elimination pulsewidth modulation (PWM) scheme. To enhance the performance of the inverter and eliminate the problem of flexibility associated with conventional and offline switching angle calculations in the PWM technique, a bioinspired intelligent algorithm is adapted. The developed system is verified for various reduced total harmonic distortions (THDs) by performing simulations and experiments. The results depict that the output voltage is regulated for varying load conditions, and the THD is observed to be 2.4% under varying load conditions.
引用
收藏
页码:6924 / 6934
页数:11
相关论文
共 37 条
  • [1] Ahmad S., 2021, STUDIES COMPUTATIONA, V916, DOI [10.1007/978-981-15-7571-6_18, DOI 10.1007/978-981-15-7571-6_18]
  • [2] Ahmad S, 2018, 3RD INTERNATIONAL CONFERENCE ON INNOVATIVE APPLICATIONS OF COMPUTATIONAL INTELLIGENCE ON POWER, ENERGY AND CONTROLS WITH THEIR IMPACT ON HUMANITY (CIPECH-18), P183
  • [3] Low-order harmonics control in staircase waveform useful in high-power application by a novel technique
    Ahmad, Salman
    Al-Hitmi, Mohammed
    Iqal, Atif
    Ashraf, Imtiaz
    Meraj, Mohammed
    Padmanaban, Sanjeevikumar
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (03)
  • [4] Selective harmonics elimination in multilevel inverter by a derivative-free iterative method under varying voltage condition
    Ahmad, Salman
    Meraj, Mohammed
    Iqbal, Atif
    Ashraf, Imtiaz
    [J]. ISA TRANSACTIONS, 2019, 92 : 241 - 256
  • [5] [Anonymous], 2011, NAT EL COD
  • [6] Chen CS, 2008, IEEE IND APPLIC SOC, P13
  • [7] Model Predictive Control of an Inverter With Output LC Filter for UPS Applications
    Cortes, Patricio
    Ortiz, Gabriel
    Yuz, Juan I.
    Rodriguez, Jose
    Vazquez, Sergio
    Franquelo, Leopoldo G.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) : 1875 - 1883
  • [8] da Silva JN, 2017, BRAZIL POWER ELECTR
  • [9] A Synchronous Reference Frame Robust Predictive Current Control for Three-Phase Grid-Connected Inverters
    Espi Huerta, Jose M.
    Castello-Moreno, Jaime
    Roberto Fischer, Jonatan
    Garcia-Gil, Rafael
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (03) : 954 - 962
  • [10] Franceschini G, 2008, IEEE IND APPLIC SOC, P121