Purpose We aimed to investigate comparability of LV volumes, function, and mass acquired with three steady-state free precession (SSFP) pulse sequences, simulating typical vendor and protocol specific differences in data acquisition. Methods Twenty-one healthy subjects (11 male and 10 female; age range 23-49) underwent cardiac magnetic resonance (CMR) imaging at 1.5 Tesla (T). A complete stack of short-axis views covering the entire left ventricle (LV) were acquired for each of the three SSFP sequences, differing in the interslice gap and slice thickness (7 mm with no gap (7/0 mm); 7 mm with a 3 mm gap (7/3 mm) and 6 mm with a 4 mm gap (6/4 mm)) with slight variations in acquisition parameters. For each sequence, the LV volumes, function, and mass were determined. Intra- and inter-observer variability and inter-study reproducibility were assessed for all protocols. Results All LV volumes, function and mass parameters were similar for the three SSFP sequences (P > 0.05 for all). The LV ejection fraction for the 7/3 mm sequence was 67.2 +/- 6.0, 67.4 +/- 5.3 for the 7/0 mm sequence, and the 6/4 mm sequence was 69.2 +/- 5.7. The LV mass ranged from 119.8 +/- 32.4 for the 7/3 mm sequence to 122.2 +/- 34.0 for the 7/0 mm sequence. Variabilities were low with no difference in variability between the sequences. Conclusion The three SSFP pulse sequence techniques resulted in similar LV volume, function, and mass measurements with no difference in observer and interstudy variabilities. This may allow application and transfer of LV volume studies and databases based on different imaging parameters, at different CMR sites, with a given post-processing method. Future multi-centre studies may now be in a position to consider multi-vendor study designs for LV volume studies.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 16 条
[1]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[2]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Operator induced variability in cardiovascular MR: left ventricular measurements and their reproducibility [J].
Danilouchkine, MG ;
Westenberg, JJM ;
de Roos, A ;
Reiber, JHC ;
Lelieveldt, BPF .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) :447-457
[5]   Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echocardiography, and radionuclide ventriculography [J].
Darasz, KH ;
Underwood, SR ;
Bayliss, J ;
Forbat, SM ;
Keegan, J ;
Poole-Wilson, PA ;
Sutton, GC .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (02) :135-142
[6]  
Di Cesare Ernesto, 1999, Rays (Rome), V24, P19
[7]   TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model [J].
Fieno, DS ;
Jaffe, WC ;
Simonetti, OP ;
Judd, RM ;
Finn, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :526-531
[8]   Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy [J].
Grothues, F ;
Smith, GC ;
Moon, JCC ;
Bellenger, NG ;
Collins, P ;
Klein, HU ;
Pennell, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (01) :29-34
[9]   Normal human left and right ventricular and left atrial dimensions using steady state free precession magnetic resonance imaging [J].
Hudsmith, LE ;
Petersen, SE ;
Francis, JM ;
Robson, MD ;
Neubauer, S .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (05) :775-782
[10]   Assessment of left ventricular function by breath-hold cine MR imaging: Comparison of different steady-state free precession sequences [J].
Kunz, RP ;
Oellig, F ;
Krummenauer, F ;
Oberholzer, K ;
Romaneehsen, B ;
Vomweg, TW ;
Horstick, G ;
Hayes, C ;
Thelen, M ;
Kreitner, KF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :140-148