Posterior Short-segmental Fixation Combined With Intermediate Screws vs Conventional Intersegmental Fixation for Monosegmental Thoracolumbar Fractures

被引:55
作者
Tian, Ji-wei [1 ]
Wang, Lei [1 ]
Xia, Tian [1 ]
Liu, Cheng-yi [1 ]
Zhao, Qing-hua [1 ]
Dong, Shuang-hai [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Dept Orthoped Surg, Shanghai 200003, Peoples R China
关键词
D O I
10.3928/01477447-20110627-08
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Posterior short-segmental fixation is reliable for the management of thoracolumbar fractures; however, it is associated with recurrence of kyphosis and failure of fixation. This study compared the short-term results of short-segmental fixation combined with intermediate screws with those of conventional intersegmental fixation in the treatment of monosegmental thoracolumbar fractures. The records of 62 consecutive patients with thoracolumbar monosegmental fractures who underwent conventional 4-screw intersegmental fixation (35 patients) or short-segmental fixation combined with intermediate screws (27 patients) were reviewed. The study population included 43 men and 19 women (mean age, 44.1±13.6 years). The majority of fractures were L1 (28 [45.1%]) and T12 (21 [33.9%]) fractures. There were no significant differences between the 2 groups with respect to the preoperative relative height of the fractured vertebra or the segmental kyphotic angle. There was a significant difference in the restoration rate between the conventional and short-segmental fixation groups (62.6±38.7% vs 100.4±25.4%, respectively; P<.001). However, a statistically significant decrease in postoperative segmental kyphotic angle was noted in both groups (P<.001). The mean change of segmental kyphotic angle in the short-segmental fixation group was greater than in the conventional fixation group (14.4±6.8° vs 8.3±7.9°, respectively; P=.002). Patients in the short-segmental fixation group ambulated an average of 10 days earlier than those in the conventional fixation group. These findings indicate that compared to conventional intersegmental fixation, short-segmental fixation combined with intermediate screws more effectively restores fractured vertebral height, is associated with a decrease in the segmental kyphotic angle, and allows earlier ambulation.
引用
收藏
页码:594 / 594
页数:1
相关论文
共 31 条
[1]  
Kifune M., Panjabi M.M., Liu W., Arand M., Vasavada A., Oxland T., Functional morphology of the spinal canal after endplate, wedge, and burst fractures, Journal of Spinal Disorders, 10, 6, pp. 457-466, (1997)
[2]  
Dick W., Kluger P., Magerl F., A new device for internal fixation of thoracolumbar and lumbar spine fractures: The 'fixateur interne, Paraplegia, 23, 4, pp. 225-232, (1985)
[3]  
Sanderson P.L., Fraser R.D., Hall D.J., Cain C.M.J., Osti O.L., Potter G.R., Short segment fixation of thoracolumbar burst fractures without fusion, European Spine Journal, 8, 6, pp. 495-500, (1999)
[4]  
Rommens P.M., Weyns F., Van Calenbergh F., Goffin J., Broos P.L., Mechanical performance of the Dick internal fixator: A clinical study of 75 patients, Eur Spine J, 4, 2, pp. 104-109, (1995)
[5]  
Alanay A., Acaroglu E., Yazici M., Oznur A., Surat A., Short-segment pedicle instrumentation of thoracolumbar burst fractures: Does transpedicular intracorporeal grafting prevent early failure?, Spine (Phila Pa 1976), 26, 2, pp. 213-217, (2001)
[6]  
McLain R.F., Sparling E., Benson D.R., Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report, Journal of Bone and Joint Surgery - Series A, 75, 2, pp. 162-167, (1993)
[7]  
Sasso R.C., Cotler H.B., Posterior instrumentation and fusion for unstable fractures and fracture-dislocations of the thoracic and lumbar spine: A comparative study of three fixation devices in 70 patients, Spine (Phila Pa 1976), 18, 4, pp. 450-460, (1993)
[8]  
Speth M.J., Oner F.C., Kadic M.A., De Klerk L.W., Verbout A.J., Recurrent kyphosis after posterior stabilization of thoracolumbar fractures: 24 cases treated with a Dick internal fixator followed for 1.5-4 years, Acta Orthop Scand, 66, 5, pp. 406-410, (1995)
[9]  
McLain R.F., Burkus J.K., Benson D.R., Segmental instrumentation for thoracic and thoracolumbar fractures: Prospective analysis of construct survival and five-year follow-up, Spine Journal, 1, 5, pp. 310-323, (2001)
[10]  
Oner F.C., Wood K.B., Smith J.S., Shaffrey C.I., Therapeutic decision making in thoracolumbar spine trauma, Spine (Phila Pa 1976), 35, 21 SUPPL., (2010)