A non-invasive real-time monitoring system for cytotoxic brain edema in post ischemic stroke based on near-field coupling

被引:3
|
作者
Li, Gen [1 ]
Zhang, Bo [1 ]
Zhang, Maoting [2 ]
Liu, Qi [1 ]
Luo, Jie [1 ]
Liao, Qi [1 ]
Tan, Mei [1 ]
Bai, Zelin [2 ]
Xu, Jia [2 ]
Sun, Jian [2 ]
Chen, Mingsheng [2 ]
机构
[1] Chongqing Univ Technol, Dept Biomed Engn, CO-400054 Chongqing, Peoples R China
[2] Army Med Univ, Coll Biomed Engn, Chongqing, Peoples R China
关键词
Cytotoxic brain edema; near-field coupling; real-time monitoring; middle cerebral artery occlusion; CEREBRAL-ARTERY OCCLUSION; PHASE-SHIFT; SPECTROSCOPY; TOMOGRAPHY; HEMORRHAGE; CARE;
D O I
10.3233/THC-202685
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: As a common secondary pathophysiological process in postischemic stroke (IS), cytotoxic brain edema (CBE) is an independent factor leading to poor prognosis of patients. Near-field coupling (NFC) technology has some advantages such as non-invasive, non-contact, and unimpeded penetration of the skull. In theory, it can reflect the difference between normal and edema tissues through the near-field coupling phase shift (NFCPS) in the electromagnetic wave transmission trait. METHODS: Combining NFC detection principle and computer programming, we established a high-performance real-time monitoring system with functions such as automatic setting of measurement parameters, data acquisition, real-time filtering and dynamic waveform display. To investigate the feasibility of this system to detect CBE, a saline simulation experiment and a 24-hour real-time monitoring experiment after middle cerebral artery occlusion (MCAO) in rats were carried out. RESULTS: The results of the saline simulation experiment showed that the change of NFCPS was proportional to the increase of the simulated edema solution, and the variation range of NFCPS was more than 9 degrees after 5 ml injection. In the 24-hour monitoring after MCAO, the NFCPS of the experimental group showed an overall downward trend over time an average change of -17.7868 +/- 1.6325 degrees and the change rate gradually decreased. The 24-hour NFCPS in the control group fluctuates slightly around the initial value, which has no obvious upward or downward trend. CONCLUSION: The intragroup and intergroup difference statistical analysis shows that NFCPS can effectively distinguish different intracranial pathophysiological states after IS. This work provides sufficient evidence and a technical basis for using NFCPS to monitor CBE in the future.
引用
收藏
页码:963 / 978
页数:16
相关论文
共 20 条
  • [1] Real-Time Passive Brain Monitoring System Using Near-Field Microwave Radiometry
    Groumpas, Evangelos
    Koutsoupidou, Maria
    Karanasiou, Irene S.
    Papageorgiou, Charalabos
    Uzunoglu, Nikolaos
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (01) : 158 - 165
  • [2] Non-invasive Assessment for Dynamic Cerebral Autoregulation Based on Near-Field Coupling
    Shao, Ansheng
    Li, Gen
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [3] Twenty-Four-Hour Real-Time Continuous Monitoring of Cerebral Edema in Rabbits Based on a Noninvasive and Noncontact System of Magnetic Induction
    Li, Gen
    Ma, Ke
    Sun, Jian
    Jin, Gui
    Qin, Mingxin
    Feng, Hua
    SENSORS, 2017, 17 (03)
  • [4] Real-Time Monitoring of Jet Trajectory during Jetting Based on Near-Field Computer Vision
    Zhu, Jinsong
    Li, Wei
    Lin, Da
    Zhao, Ge
    SENSORS, 2019, 19 (03)
  • [5] Early assessment of acute ischemic stroke in rabbits based on multi-parameter near-field coupling sensing
    Li, Gen
    Yin, Shengtong
    Jian, Man
    Chen, Jingbo
    Zeng, Lingxi
    Bai, Zelin
    Zhuang, Wei
    Xu, Bingxin
    He, Shengjie
    Sun, Jian
    Chen, Yujie
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)
  • [6] Non-destructive, non-invasive, in-line real-time phase-based reflectance for quality monitoring of fruit
    Assaad, M.
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2020, 13 (01): : 1 - 10
  • [7] Early assessment of acute ischemic stroke in rabbits based on multi-parameter near-field coupling sensing
    Gen Li
    Shengtong Yin
    Man Jian
    Jingbo Chen
    Lingxi Zeng
    Zelin Bai
    Wei Zhuang
    Bingxin Xu
    Shengjie He
    Jian Sun
    Yujie Chen
    BioMedical Engineering OnLine, 21
  • [8] Near-Infrared Afterglow ONOO--Triggered Nanoparticles for Real-Time Monitoring and Treatment of Early Ischemic Stroke
    Zhang, Liping
    Wang, Ya-chao
    Liao, Yuqi
    Zhang, Qian
    Liu, Xia
    Zhu, Dongxia
    Feng, Haixing
    Bryce, Martin R.
    Ren, Lijie
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (39) : 45574 - 45584
  • [9] A Non-invasive Real-Time Methodology for the Quantification of Antioxidant Properties in Coffee During the Roasting Process Based on Near-Infrared Spectroscopy
    Catelani, Tiago A.
    Pascoa, Ricardo N. M. J.
    Santos, Joao Rodrigo
    Pezza, Leonardo
    Pezza, Helena R.
    Lima, Jose L. F. C.
    Lopes, Joao A.
    FOOD AND BIOPROCESS TECHNOLOGY, 2017, 10 (04) : 630 - 638
  • [10] A Non-invasive Real-Time Methodology for the Quantification of Antioxidant Properties in Coffee During the Roasting Process Based on Near-Infrared Spectroscopy
    Tiago A. Catelani
    Ricardo N. M. J. Páscoa
    João Rodrigo Santos
    Leonardo Pezza
    Helena R. Pezza
    José L. F. C. Lima
    João A. Lopes
    Food and Bioprocess Technology, 2017, 10 : 630 - 638