The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control

被引:170
作者
Chico, A
Vidal-Ríos, P
Subirà, M
Novials, A
机构
[1] Fdn Sarda Farriol, Inst Diabetol, Barcelona 08017, Spain
[2] Ctr Diabet, La Coruna, Spain
关键词
D O I
10.2337/diacare.26.4.1153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate whether the continuous glucose monitoring system (CGMS; MiniMed, Sylmar, CA) is useful for investigating the incidence of unrecognized hypoglycemias in type I and type 2 diabetic patients and for improving metabolic control in type I diabetic patients. RESEARCH DESIGN AND METHODS - A total of 70 diabetic subjects (40 type I and 30 type 2 subjects) were monitored using the CGMS. The number of unrecognized hypoglycemias was registered. Furthermore, the 40 type I diabetic patients whose treatment was modified in accordance with the information obtained from the CGMS were compared with a control group of 35 different type I diabetic patients using intensive capillary glucose measurements. HbA(1c) levels were measured before the monitoring period and 3 months later. RESULTS - The CGMS detected unrecognized hypoglycemias in 62.5% of the type I diabetic patients and in 46.6% of the type 2 diabetic patients. We found that 73.7% of all events occurred at night. HbA(1c) concentrations decreased significantly in both the group of type I diabetic subjects monitored with the CGMS (from 8.3 +/- 1.6 to 7.5 +/- 1.2%, P < 0.01) and the control group (from 8.0 +/- 1.4 to 7.5 +/- 0.8%, P < 0.01). The greatest reduction was observed in the subgroup of patients who started continuous subcutaneous insulin infusion therapy, both in the CGMS-monitored and control groups (from 9.4 +/- 2 to 7.2 +/- 1.4% and from 8.1 +/- 1.8 to 7.1 +/- 0.6%, respectively). CONCLUSIONS - The CGMS is useful for detecting unrecognized hypoglycemias in type I and type 2 diabetic subjects; however, it is not better than standard capillary glucose measurements for improving metabolic control of type I diabetic subjects, regardless of the therapeutic regimen.
引用
收藏
页码:1153 / 1157
页数:5
相关论文
共 28 条
  • [1] American Diabetes Association, 1998, DIABETES CARE, pS23
  • [2] [Anonymous], 1996, DIABETES CARE, V19, pS62
  • [3] Bell D S, 2000, Endocr Pract, V6, P357
  • [4] Bode BW, 2000, DIABETES, V49, pA97
  • [5] Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study
    Bode, BW
    Gross, TM
    Thornton, KR
    Mastrototaro, JJ
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1999, 46 (03) : 183 - 190
  • [6] BODE BW, 2000, DIABETES SPECTRUM, V13, P171
  • [7] Limitations of conventional methods of self-monitoring of blood glucose - Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes
    Boland, E
    Monsod, T
    Delucia, M
    Brandt, CA
    Fernando, S
    Tamborlane, WV
    [J]. DIABETES CARE, 2001, 24 (11) : 1858 - 1862
  • [8] NOCTURNAL BLOOD-GLUCOSE CONTROL IN TYPE-I DIABETES-MELLITUS
    BOLLI, GB
    FANELLI, CG
    PERRIELLO, G
    DEFEO, P
    [J]. DIABETES CARE, 1993, 16 : 71 - 89
  • [9] CHEYNE E, 2000, DIABETOLOGIA, V43, pA790
  • [10] Chico A, 2001, ENDOCRINOL NUTR, V48, P266