In Vivo Intraocular Lens Thickness Measurement and Power Estimation Using Optical Coherence Tomography

被引:1
作者
Barzanouni, Ehsan [1 ,2 ]
Idani, Diba [3 ]
Sharifipour, Farideh [1 ,2 ]
机构
[1] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Res Inst Ophthalmol & Vis Sci, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Sch Med, Dept Ophthalmol, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Med, Tehran, Iran
关键词
Anterior Segment Optical Coherence Tomography; AS-OCT; Intraocular Lens; IOL; IOL Thickness; SCHEIMPFLUG; SYSTEM; OCT;
D O I
10.18502/jovr.v17i3.11572
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To estimate the power of an implanted intraocular lens (IOL) by measuring IOL thickness using anterior segment optical coherence tomography (AS-OCT) and to assess the repeatability of measurements. Methods: Ninety-seven eyes were studied one month after uneventful phacoemulsification within the bag Acrysof SA60AT IOL implantation (range +11 to +35). All eyes had postoperative refraction of +/- 0.5 D of target refraction. AS-OCT was used to measure the central thickness of the IOL. Correlation between labelled IOL power and central IOL thickness as well as the measure of repeatability, for example, intraclass correlation coefficient (ICC), were evaluated. IOL thicknesses were also calculated using a formula and compared with AS-OCT derived measurements. Results: IOL thickness correlated significantly with labelled IOL power (R-2 = 0.985, P < 0.001). The regression equation (IOL Power = [0.04 x IOL thickness in micron] - 7.56) indicates 25 microns of central IOL thickness change per 1D power change. Over the studied range, IOL power could be estimated with a precision of 0.85 +/- 0.02 D (95% confidence interval: 0.83-0.94D). ICC for repeated measurements was 0.999. There was a significant correlation between calculated and measured (AS-OCT) IOL thickness (R-2 = 0.984, P < 0.001). Conclusion: Central IOL thickness measurements with the AS-OCT are highly repeatable and closely correlated with the labelled IOL power, which can predict the IOL power with +/- 0.85 D from the actual power. This method can be helpful in cases of postoperative IOL surprise.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 13 条
  • [1] Anterior segment optical coherence tomography
    Ang, Marcus
    Baskaran, Mani
    Werkmeister, Rene M.
    Chua, Jacqueline
    Schmidl, Doreen
    dos Santos, Valentin Aranha
    Garhoefer, Gerhard
    Mehta, Jodhbir S.
    Schmetterer, Leopold
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 : 132 - 156
  • [2] "Numbers sometimes lie"- refractive surprise following IOL mislabeling by the manufacturer
    Anticic, Marija
    Ardjomand, Navid
    Sarny, Stephanie
    Schweighofer, Jakob
    El-Shabrawi, Yosuf
    [J]. EYE, 2019, 33 (06) : 868 - 870
  • [3] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1729 - 1735
  • [4] Kanellopoulos AJ, 2013, CLIN OPHTHALMOL, V7, P2239, DOI 10.2147/OPTH.S53718
  • [6] Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT
    Leung, Christopher Kai-Shun
    Li, Haitao
    Weinreb, Robert Neal
    Liu, Jing
    Cheung, Carol Yim Lui
    Lai, Ricky Yiu Kwong
    Pang, Chi Pui
    Lam, Dennis Shun Chiu
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3469 - 3474
  • [7] McReynolds W U, 1978, J Am Intraocul Implant Soc, V4, P15
  • [8] CALCULATION OF THE THICKNESS OF AN INTRAOCULAR-LENS
    NAESER, K
    NAESER, EV
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01) : 40 - 42
  • [9] Calculation of intraocular lens power: a review
    Olsen, Thomas
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (05): : 472 - 485
  • [10] Refractive surprise following implantation of correct powered intraocular lens - A real surprise!
    Kumar Ravi
    Sirisha Senthil
    Veerendranath Pesala
    [J]. International Ophthalmology, 2012, 32 (6) : 603 - 605