The Auto-Focusing Remote Laser-Induced Breakdown Spectroscopy System

被引:7
作者
Han Zhen-yu [1 ]
Pan Cong-yuan [1 ]
An Ning [1 ]
Du Xue-wei [1 ]
Yu Yun-si [1 ]
Du Liang-liang [2 ]
Wang Sheng-bo [3 ]
Wang Qiu-ping [1 ]
机构
[1] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Peoples R China
[2] Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, Hefei 230027, Peoples R China
[3] Univ Sci & Technol China, Dept Opt & Opt Engn, Hefei 230026, Peoples R China
关键词
Laser-induced breakdown spectroscopy; Remote measurement; Telescope; Auto-focusing; IN-SITU ANALYSIS;
D O I
10.3964/j.issn.1000-0593(2015)02-0304-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The present paper presents an auto-focus laser-induced breakdown spectroscopy (LIBS) remote measuring system. This system contains a Schwarzschild telescope, which consists of a convex mirror and a concave mirror. The two spherical mirrors are coaxially placed. The convex mirror is mounted on a motorized linear translation stage. With this motorized linear translation stage, the convex mirror can move along the optical axis to change the spacing between the convex mirror and the concave mirror. Therefore the focal length can be adjusted to focus the laser on samples at different distances and collect the plasma spectra. The advantages of the telescope system include, firstly, the light path of laser focusing and spectra signal collection is the same, which make it easier for mounting and collimation; secondly, the light path of the telescope uses total reflection type, which is fit for the detection in ultra-violate region; finally, the telescope consists of only two spherical mirrors which are relatively easier to manufacture. Within the translation range of the motorized linear translation stage, the focal length of the telescope in this paper can be adjusted from 1. 5 to 3. 6 m. The diameter of the focusing spot varies from 0. 5 to 1. 0 mm. Utilizing this telescope system, LIPS experiments were conducted using copper sample. And the characteristic lines of Cu element (Cu I 223. 01 nm, Cu I 224. 43 nm) obtained are used for the auto focusing. By investigating the relation of the area of spectral lines covered and the spacing between the mirrors, the optimal laser focusing location was obtained. The LIBS experiment results show that the system functions well, fulfilling the demand of remote ablation of sample and LIBS spectral measuring, and the telescope is able to auto-focus the laser on samples at different position to perform remote LIBS experiment.
引用
收藏
页码:304 / 308
页数:5
相关论文
共 12 条
[1]   Schwarzschild objective for soft x-rays [J].
Artioukov, IA ;
Krymski, KM .
OPTICAL ENGINEERING, 2000, 39 (08) :2163-2170
[2]   Laser-induced breakdown spectroscopy in industrial and security applications [J].
Bol'shakov, Alexander A. ;
Yoo, Jong H. ;
Liu, Chunyi ;
Plumer, John R. ;
Russo, Richard E. .
APPLIED OPTICS, 2010, 49 (13) :C132-C142
[3]   Strategies for Mars remote Laser-Induced Breakdown Spectroscopy analysis of sulfur in geological samples [J].
Dyar, M. Darby ;
Tucker, Jonathan M. ;
Humphries, Seth ;
Clegg, Samuel M. ;
Wiens, Roger C. ;
Lane, Melissa D. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (01) :39-56
[4]   In situ analysis of metal melts in metallurgic vacuum devices by laser-induced breakdown spectroscopy [J].
Gruber, J ;
Heitz, J ;
Arnold, N ;
Bäuerle, D ;
Ramaseder, N ;
Meyer, W ;
Hochörtler, J ;
Koch, F .
APPLIED SPECTROSCOPY, 2004, 58 (04) :457-462
[5]   Rapid in-situ analysis of liquid steel by laser-induced breakdown spectroscopy [J].
Gruber, J ;
Heitz, J ;
Strasser, H ;
Bäuerle, D ;
Ramaseder, N .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) :685-693
[6]  
Handke J U R, 2011, STANDOFF DETECTION A
[7]  
HORIKAWA Y, 1992, P SOC PHOTO-OPT INS, V1720, P217, DOI 10.1117/12.132128
[8]  
Khater M A, 2013, SPECTROCHIM ACTA B, V81, P1
[9]   Monitoring of toxic elements present in sludge of industrial waste using CF-LIBS [J].
Kumar, Rohit ;
Rai, Awadhesh K. ;
Alamelu, Devanathan ;
Aggarwal, Suresh K. .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (01) :171-180
[10]   Simultaneous Raman Spectroscopy-Laser-induced Breakdown Spectroscopy for Instant Standoff Analysis of Explosives Using a Mobile Integrated Sensor Platform [J].
Moros, Javier ;
Antonio Lorenzo, Juan ;
Lucena, Patricia ;
Miguel Tobaria, Luciano ;
Javier Laserna, Jose .
ANALYTICAL CHEMISTRY, 2010, 82 (04) :1389-1400