Anteromedial femoral neck plate with cannulated screws for the treatment of irreducible displaced femoral neck fracture in young patients: a preliminary study

被引:26
|
作者
Zhuang, Linbo [1 ]
Wang, Lisheng [1 ]
Xu, Dongming [1 ]
Wang, Zhiyong [1 ]
机构
[1] Shenzhen Univ, Dept Orthoped, Baoan Cent Hosp Shenzhen, Affiliated Hosp 5,Hlth Sci Ctr, Shenzhen 518102, Guangdong, Peoples R China
关键词
Femoral neck fracture; Anteromedial femoral neck plate; Cannulated screws; Open reduction; Avascular necrosis; Nonunion; DYNAMIC HIP SCREW; BLADE PLATE; FIXATION; REDUCTION; NONUNION; MANAGEMENT; NECROSIS; IMPLANT; GRAFT; HEAD;
D O I
10.1007/s00068-018-0972-1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Backgrounds Although most displaced femoral neck fractures of young patients can be repositioned successfully by closed reduction, there are still some can not repositioned successfully by this way and open reductions are required. This type of fracture was defined as irreducible displaced femoral neck fracture in this study. The purpose of this study was to introduce a new technique using anteromedial femoral neck plate with cannulated screws fixation by open reduction for the treatment of irreducible displaced femoral neck fractures in young patients. Methods Totally 26 patients with irreducible displaced femoral neck fracture treated by this technique were retrospectively reviewed. This technique included three major steps: open reduction of femoral neck fracture was performed via the modified anterior approach of hip joint, anteromedial femoral neck plate was fixed to the femoral neck, and two cannulated compression screws were inserted in the femoral neck inside. Results All patients were followed up with an average of 18months (range 12-30 months). Radiological and clinical outcomes were evaluated. The fracture union was achieved in 24 patients (92.3%) with an average duration of 4.5 months (range 3.8-10 months). Nonunion was not observed in all cases. Avascular necrosis of femoral head was identified in two patients (7.7%). Clinical outcomes of 24 hips with satisfactory union were evaluated by the Harris Hip Scores (HHS), excellent outcomes were achieved in 20 cases (HHS >= 90), fair outcomes in 3 cases (80 <= HHS < 90), and poor outcome in 1 case (HHS < 80). Conclusions Anteromedial femoral neck plate with cannulated screws fixation by open reduction is an alternative therapeutic method for the irreducible displaced femoral neck fracture in young patients, with low incidence of complications including nonunion and avascular necrosis.
引用
收藏
页码:995 / 1002
页数:8
相关论文
共 50 条
  • [41] RETRACTED: A Comparative Study between Proximal Femoral Locking Plate and Multiple Cannulated Screws for Fixation of Femoral Neck Fractures in Young Adults (Retracted Article)
    Zhang, Jun
    Zhuang, Yunqiang
    Dai, Li
    Huang, Dichao
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [42] Surgical treatment with cannulated screws for pediatric femoral neck fractures: A case series
    Pavone, Vito
    Testa, Gianluca
    Riccioli, Maria
    Di Stefano, Antonio
    Condorelli, Giuseppe
    Sessa, Giuseppe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : S40 - S44
  • [43] Influence of time to surgery on the incidence of complications in femoral neck fracture treated with cannulated screws
    Freitas Araujo, Thiego Pedro
    Guimaraes, Tales Mollica
    Andrade-Silva, Fernando Brandao
    Kojima, Kodi Edson
    Silva, Jorge dos Santos
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S36 - S39
  • [44] Effect of cannulated screws with deep circumflex iliac artery-bone grafting in the treatment of femoral neck fracture in young adults
    Li, Guanghui
    Jin, Dadi
    Shao, Xianfang
    Liu, Zhijun
    Duan, Jianhui
    Akileh, Raji
    Cao, Shousong
    Liu, Tuoen
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (08): : 1587 - 1593
  • [45] The comparison of femoral neck system and cancellous screws internal fixation for femoral neck fracture
    Jiang, Tao
    Gao, Han
    Xu, Bin
    Lv, Fuxin
    Liu, Tao
    BIOTECHNOLOGY AND GENETIC ENGINEERING REVIEWS, 2023,
  • [46] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667
  • [47] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Weil, Yoram A.
    Qawasmi, Feras
    Liebergall, Meir
    Mosheiff, Rami
    Khoury, Amal
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (05) : 661 - 667
  • [48] Prediction of Reoperation of Femoral Neck Fractures Treated With Cannulated Screws in Elderly Patients
    Gregersen, Merete
    Krogshede, Anna
    Brink, Ole
    Damsgaard, Else Marie
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2015, 6 (04) : 322 - 327
  • [49] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [50] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua
    BIOMEDICAL ENGINEERING ONLINE, 2022, 21 (01)