Glaucoma Medication and Quality of Life after Phacoemulsification Combined with a Xen Gel Stent

被引:5
作者
Pahljina, Christian [1 ]
Sarny, Stephanie [1 ]
Hoeflechner, Lukas [1 ]
Falb, Thomas [1 ]
Schliessleder, Gernot [1 ]
Lindner, Marlene [2 ]
Ivastinovic, Domagoj [1 ]
Mansouri, Kaweh [3 ]
Lindner, Ewald [1 ]
机构
[1] Med Univ Graz, Dept Ophthalmol, A-8036 Graz, Austria
[2] Med Univ Graz, Dept Dent, A-8036 Graz, Austria
[3] Swiss Visio, Glaucoma Res Ctr, Montchoisi Clin, CH-1006 Lausanne, Switzerland
关键词
glaucoma; quality of life; surveys and questionnaires; minimal invasive glaucoma surgery; Xen gel stent; OCULAR SURFACE DISEASE; DRY EYE; SYMPTOM SCALE; PATIENT SATISFACTION; VISUAL-ACUITY; PREVALENCE; VALIDATION; TRIAL;
D O I
10.3390/jcm11123450
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Glaucoma has a significant impact on quality of life. Here, we aimed to evaluate the influence of a reduction in glaucoma medications on quality of life and patient satisfaction after phacoemulsification combined with the Xen gel stent. We carried out a cross-sectional survey of patients who underwent phacoemulsification with the Xen gel stent at the Medical University of Graz, Austria. Quality of life was assessed using the German version of the Glaucoma Symptoms Scale (GSS)-questionnaire. Patients were also asked whether the operation reduced glaucoma medications and to indicate their overall satisfaction from 1 (totally discontented) up to 10 (totally contented). Questionnaires of 80 patients were evaluated. A total of 36 patients (45.0%) reported a reduction in glaucoma medications. Three items of the GSS were significantly better in patients who needed fewer glaucoma medications after the operation ("hard to see in daylight", 75.0 +/- 31.1 vs. 57.7 +/- 39.1, p = 0.035; "hard to see in dark places", 81.1 +/- 28.7 vs. 54.9 +/- 41.2, p = 0.002; and "halos around lights", 88.3 +/- 25.9 vs. 68.8 +/- 38.6, p = 0.002). Patient satisfaction was significantly higher when the procedure led to a reduction in glaucoma medication (8.3 +/- 2.0 vs. 6.8 +/- 3.1; p = 0.034). The reported quality of life and patient satisfaction were significantly better when phacoemulsification with the Xen gel stent reduced the number of glaucoma medications needed.
引用
收藏
页数:7
相关论文
共 50 条
[31]   Complications Following XEN45 Gel Stent and Glaucoma Drainage Device Implantation During Glaucoma Fellowship [J].
Lentz, P. Connor ;
Wagner, Isabella V. ;
Draper, Christian ;
Ang, Bryan ;
Boopathiraj, Nithya ;
Miller, Darby ;
Dorairaj, Syril .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
[32]   Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature [J].
Panarelli, Joseph F. ;
Vera, Vanessa ;
Sheybani, Arsham ;
Radcliffe, Nathan ;
Fiscella, Richard ;
Francis, Brian A. ;
Smith, Oluwatosin U. ;
Noecker, Robert J. .
CLINICAL OPHTHALMOLOGY, 2023, 17 :25-46
[33]   XEN45 gel stent in the treatment of pigmentary glaucoma: A two-year follow-up [J].
Gassel, Caroline J. ;
Nasyrov, Emil ;
Wenzel, Daniel A. ;
Voykov, Bogomil .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025, 35 (01) :172-180
[34]   Ab-Externo Implantation of XEN Gel Stent for Refractory Steroid-Induced Glaucoma After Lamellar Keratoplasty [J].
Tan, Shu Yu ;
Din, Norshamsiah Md ;
Khialdin, Safinaz Mohd ;
Halim, Wan Haslina Wan Abdul ;
Tang, Seng Fai .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (02)
[35]   XEN45 Gel Stent Combined with Healaflow Injectable Viscoelastic Implant [J].
Villarreal, Eloy ;
Berkowitz, Eran ;
Tiosano, Beatrice .
CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2023, 2023
[36]   Delayed Suprachoroidal Hemorrhage After Xen45 Gel Stent [J].
Pham, Anh H. ;
Junk, Anna K. .
JOURNAL OF GLAUCOMA, 2023, 32 (04) :E33-E35
[37]   A Case of Bilateral Choroidal Effusion after XEN Gel Stent Implantation [J].
Cassottana, Paola ;
Toma, Chiara ;
Maltese, Cristina ;
Villa, Viviana ;
Ricciarelli, Roberta ;
Traverso, Carlo Enrico ;
Iester, Michele .
GELS, 2023, 9 (04)
[38]   One year efficacy and safety of inferior implantation of Xen 45® Gel Stent in refractory glaucoma [J].
Bastelica, P. ;
Amatu, J. -B. ;
Buffault, J. ;
Majoulet, A. ;
Labbe, A. ;
Baudouin, C. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (08)
[39]   Safety and Efficacy of Ab Interno XEN 45 Gel Stent in Patients with Glaucoma and High Myopia [J].
Sacchi, Matteo ;
Fea, Antonio M. ;
Monsellato, Gianluca ;
Tagliabue, Elena ;
Villani, Edoardo ;
Ranno, Stefano ;
Nucci, Paolo .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
[40]   Outcomes of Deep Sclerectomy following Failed XEN Gel Stent Implantation in Open-Angle Glaucoma: A Prospective Study [J].
Bravetti, Giorgio Enrico ;
Gillmann, Kevin ;
Rao, Harsha L. ;
Mermoud, Andre ;
Mansouri, Kaweh .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (16)