Biomechanical stability of complex coronal plane fracture fixation of the capitellum

被引:3
作者
Borbas, Paul [1 ]
Loucas, Rafael [1 ]
Loucas, Marios [1 ]
Vetter, Maximilian [1 ]
Hofstede, Simon [2 ]
Ernstbrunner, Lukas [1 ]
Wieser, Karl [1 ]
机构
[1] Balgrist Univ Hosp, Dept Orthoped, Forchstr 340, CH-8008 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomech, Zurich, Switzerland
关键词
Distal humerus; Capitellum; Complex coronal plane fracture; Antiglide plate; Locking plate; Biomechanics; INTERNAL-FIXATION; SHEAR FRACTURES; OPEN REDUCTION;
D O I
10.1007/s00402-021-04126-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Coronal plane fractures of the distal humerus are relatively rare and can be challenging to treat due to their complexity and intra-articular nature. There is no gold standard for surgical management of these complex fractures. The purpose of this study was to compare the biomechanical stability and strength of two different internal fixation techniques for complex coronal plane fractures of the capitellum with posterior comminution. Materials and methods Fourteen fresh frozen, age- and gender-matched cadaveric elbows were 3D-navigated osteotomized simulating a Dubberley type IIB fracture. Specimens were randomized into one of two treatment groups and stabilized with an anterior antiglide plate with additional anteroposterior cannulated headless compression screws (group antiGP + HCS) or a posterolateral distal humerus locking plate with lateral extension (group PLP). Cyclic testing was performed with 75 N over 2000 cycles and ultimately until construct failure. Data were analyzed for displacement, construct stiffness, and ultimate load to failure. Results There was no significant difference in displacement during 2000 cycles (p = 0.291), stiffness (310 vs. 347 N/mm; p = 0.612) or ultimate load to failure (649 +/- 351 vs. 887 +/- 187 N; p = 0.140) between the two groups. Conclusions Posterolateral distal humerus locking plate achieves equal biomechanical fixation strength as an anterior antiglide plate with additional anteroposterior cannulated headless compression screws for fracture fixation of complex coronal plane fractures of the capitellum. These results support the use of a posterolateral distal humerus locking plate considering the clinical advantages of less invasive surgery and extraarticular metalware.
引用
收藏
页码:3239 / 3246
页数:8
相关论文
共 35 条
[1]   FRACTURE OF CAPITULUM HUMERI [J].
ALVAREZ, E ;
PATEL, MR ;
NIMBERG, G ;
PEARLMAN, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, 57 (08) :1093-1096
[2]   Transarticular shear fractures of the distal humerus [J].
Ashwood, Neil ;
Verma, Manish ;
Hamlet, Mark ;
Garlapati, Anand ;
Fogg, Quentin .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (01) :46-52
[3]   Biomechanical stability of simple coronal shear fracture fixation of the capitellum [J].
Borbas, Paul ;
Vetter, Maximilian ;
Loucas, Rafael ;
Hofstede, Simon ;
Wieser, Karl ;
Ernstbrunner, Lukas .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (08) :1768-1773
[4]   Nonunion of Operatively Treated Capitellum and Trochlear Fractures [J].
Brouwer, Kim M. ;
Jupiter, Jesse B. ;
Ring, David .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (05) :804-807
[5]  
Bryan RM., 1985, The elbow and its disorders, V1, P325
[6]   Outcome after the surgical treatment of the Dubberley type B distal humeral capitellar and trochlear fractures with a buttress plate [J].
Demir, Muhammed Taha ;
Birsel, Sema Ertan ;
Salih, Muhammet ;
Pirincci, Yusuf ;
Birsel, Olgar ;
Kesmezacar, Hayrettin .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2020, 54 (04) :364-371
[7]   Outcome after open reduction and internal fixation of capitellar and trochlear fractures [J].
Dubberley, JH ;
Faber, KJ ;
MacDermid, JC ;
Patterson, SD ;
King, GJW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01) :46-54
[8]   Capitellum fractures: A biomechanical evaluation of three fixation methods [J].
Elkowitz, SJ ;
Polatsch, DB ;
Egol, KA ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (07) :503-506
[9]   FRACTURE OF CAPITULUM HUMERI - TREATMENT BY EXCISION [J].
FOWLES, JV ;
KASSAB, MT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (04) :794-798
[10]  
GRANTHAM SA, 1981, CLIN ORTHOP RELAT R, P262