Comparison of multi-pole shaping and delay fine clipping pre-amplifiers for position sensitive NaI(Tl) detectors

被引:5
作者
Freifelder, R [1 ]
Karp, JS
Wear, JA
Lockyer, NS
Newcomer, FM
Surti, S
Van Berg, R
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Phys, Philadelphia, PA 19104 USA
关键词
D O I
10.1109/23.681992
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
NaI(TI) position sensitive detectors have been used in medical imaging for many years. For PET applications without collimators, the high counting rates place severe demands on such large area detectors. The NaI(TI) detectors in the PENN-PET scanners are read-out via photomultiplier tubes and preamplifiers. Those preamplifiers use a delay-line clipping technique to shorten the characteristic 240 ns fall time of the NaI(TI) signal. As an alternative, we have investigated a pole-zero network to shorten the signal followed by a multi-pole shaper to produce a symmetric signal suitable for high counting rates. This has been compared to our cut-rent design by measuring the energy and spatial resolution of a single detector as a function of different preamplifier designs. Data were taken over a range of ADC integration times and countrates. The new design shows improved energy resolution with short integration times. Effects on spatial resolution and deadtime are reported for large position sensitive detectors at different countrates.
引用
收藏
页码:1138 / 1143
页数:6
相关论文
共 10 条
[1]   SHORTENING OF DETECTOR SIGNALS WITH PASSIVE FILTERS FOR PILE-UP REDUCTION [J].
AMSEL, G ;
BOSSHARD, R ;
ZAJDE, C .
NUCLEAR INSTRUMENTS & METHODS, 1969, 71 (01) :1-+
[3]   MAXIMUM A POSTERIORI ESTIMATION OF POSITION IN SCINTILLATION CAMERAS [J].
GRAY, RM ;
MACOVSKI, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) :849-852
[4]   A PRACTICAL APPROACH TO BALLISTIC DEFICIT CORRECTION [J].
HINSHAW, SM ;
LANDIS, DA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :374-377
[5]  
Karp JS, 1997, J NUCL MED, V38, P636
[6]   EVENT LOCALIZATION IN A CONTINUOUS SCINTILLATION DETECTOR USING DIGITAL PROCESSING [J].
KARP, JS ;
MUEHLLEHNER, G ;
BEERBOHM, D ;
MANKOFF, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :550-555
[7]   THE HIGH COUNT RATE PERFORMANCE OF A 2-DIMENSIONALLY POSITION-SENSITIVE DETECTOR FOR POSITRON EMISSION TOMOGRAPHY [J].
MANKOFF, DA ;
MUEHLLEHNER, G ;
KARP, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (04) :437-456
[8]   LOW-NOISE TECHNIQUES IN DETECTORS [J].
RADEKA, V .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1988, 38 :217-277
[9]  
Wear JA, 1997, J NUCL MED, V38, P540
[10]  
WEAR JA, 1997, 1997 IEEE NUCL SCI S