Numerical study of the use of photovoltaic - Trombe wall in residential buildings in Tibet

被引:10
作者
Ji, J. [1 ]
Yi, H. [1 ]
Pei, G. [1 ]
He, H. F. [1 ]
Han, C. W. [1 ]
Luo, C. L. [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China
关键词
PV-Trombe wall; design; simulation; residential building in Tibet;
D O I
10.1243/09576509JPE364
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the current paper, the thermal and electrical performance of photovoltaic (PV)-Trombe wall (PV-TW) used in Tibetan residential buildings is investigated, and two performance influencing factors are analysed. Based on the original model, the PV-TW's model for residential buildings is updated, and then a simple design is performed for a given residential building in Tibet. The results show that the indoor temperature increases linearly, whereas the electrical efficiency remains almost constant, when the PV-TWs width increases. In addition, thermal insulation is found to be quite effective to improve the thermal performance, whereas it decreases the electrical performance only a little. After choosing a width of 1.70 m, the average indoor temperatures are 10.2 degrees C and 24.0 degrees C for PV-TW system with and without thermal insulation, respectively. Besides, the average electrical power can satisfy the requirement of 100W, with an electrical efficiency of 10-11 per cent.
引用
收藏
页码:1131 / 1140