Mechanical stimulation of tendon tissue engineered constructs: Effects on construct stiffness, repair biomechanics, and their correlation

被引:59
作者
Shearn, Jason T. [1 ]
Juncosa-Melvin, Natalia [1 ]
Boivin, Gregory P. [2 ,3 ]
Galloway, Marc T. [4 ]
Goodwin, Wendy [1 ]
Gooch, Cynthia [1 ]
Dunn, Michael G. [5 ]
Butler, David L. [1 ]
机构
[1] Univ Cincinnati, Dept Biomed Engn, Tissue Engn & Biomech Lab, Cincinnati, OH 45221 USA
[2] Vet Adm Med Ctr, Cincinnati, OH 45220 USA
[3] Univ Cincinnati, Dept Pathol & Lab Med, Cincinnati, OH 45267 USA
[4] Cincinnati Sports Med & Orthopaed Ctr, Cincinnati, OH 45249 USA
[5] Ropbert Wood Johnson Med Ctr, Dept Orthoped Surg, New Brunswick, NJ 08903 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 06期
关键词
D O I
10.1115/1.2800769
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objective of this study was to determine how in vitro mechanical stimulation of tissue engineered constructs affects their stiffness and modulus in culture and tendon repair biomechanics 12 weeks after surgical implantation. Using six female adult New Zealand White rabbits, autogenous tissue engineered constructs were created by seeding mesenchymal stem cells (0.1 X 10(6) cells/ml) in collagen gel (2.6 mg/ml) and combining both with a collagen sponge. Employing a novel experimental design strategy, four constructs from each animal were mechanically stimulated (one 1 Hz cycle every 5 min to 2.4% peak strain for 8 h/ day for 2 weeks) while the other four remained unstretched during the 2 week culture period. At the end of incubation, three of the mechanically stimulated (S) and three of the nonstinrulated (NS) constructs front each animal were assigned for in vitro mechanical testing while the other two autogenous constructs were implanted into. bilateral full-thickness, full-length defects created in the central third of rabbit patellar tendons (PTs). No significant differences were found in the in vitro linear stiffnesses between the S (0.15 +/- 0.1 N/mm) and NS constructs (0.08 +/- 0.02 N/mm; mean +/- SD). However, in vitro mechanical stimulation significantly increased the structural and material properties of the repair tissue, including a 14% increase in maximum force (p =0.01), a 50% increase in linear stiffness (p=0.001), and 23-41% increases in maximum stress and modulus (p=0.01). The S repairs achieved 65%, 80%, 60%, and 40% of normal central PT maximum force, linear stiffness, maximum stress, and linear modulus, respectively. The results for the S constructs exceed values obtained previously by our group using the same animal and defect model, and to our knowledge, this is the first study to show the benefits of in vitro mechanical stimulation on tendon repair biomechanics. In addition, the linear stiffnesses,for the construct and repair were positively correlated (r=0.56) as were their linear moduli (r=0.68). Such in vitro predictors of in vivo outcome hold tire potential to speed the development of tissue engineered products by reducing the time and costs of in vivo studies.
引用
收藏
页码:848 / 854
页数:7
相关论文
共 31 条
[1]   Cell differentiation by mechanical stress [J].
Altman, GH ;
Horan, RL ;
Martin, I ;
Farhadi, J ;
Stark, PRH ;
Volloch, V ;
Richmond, JC ;
Vunjak-Novakovic, G ;
Kaplan, DL .
FASEB JOURNAL, 2001, 15 (14) :270-+
[2]  
AULICINO PL, 1995, HAND CLIN, V11, P403
[3]   Repair of patellar tendon injuries using a cell-collagen composite [J].
Awad, HA ;
Boivin, GP ;
Dressler, MR ;
Smith, FNL ;
Young, RG ;
Butler, DL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (03) :420-431
[4]   RESISTANCE OF A DEFECT OF THE SUPRASPINATUS TENDON TO INTRAARTICULAR HYDRODYNAMIC PRESSURE - AN EXPERIMENTAL-STUDY ON RABBITS [J].
BJORKENHEIM, JM ;
PAAVOLAINEN, P ;
AHOVUO, J ;
SLATIS, P .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (02) :175-179
[5]  
BLAIR WF, 1992, ORTHOP CLIN N AM, V23, P141
[6]   THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
BLEVINS, FT ;
HECKER, AT ;
BIGLER, GT ;
BOLAND, AL ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :328-333
[7]   RUPTURE OF THE PATELLAR LIGAMENT AFTER USE OF ITS CENTRAL 3RD FOR ANTERIOR CRUCIATE RECONSTRUCTION - A REPORT OF 2 CASES [J].
BONAMO, JJ ;
KRINICK, RM ;
SPORN, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1294-1297
[8]   Functional tissue engineering: The role of biomechanics [J].
Butler, DL ;
Goldstein, SA ;
Guilak, F .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (06) :570-575
[9]   ANTERIOR CRUCIATE LIGAMENT - ITS NORMAL RESPONSE AND REPLACEMENT [J].
BUTLER, DL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :910-921
[10]  
DAWSON WJ, 1994, HAND CLIN, V10, P315