Effect of branch orientation on annular two-phase flow in T-junctions

被引:5
作者
Peng, F [1 ]
Shoukri, M [1 ]
Chan, AMC [1 ]
机构
[1] ONTARIO HYDRO,DIV RES,TORONTO,ON M8Z 5S4,CANADA
来源
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME | 1996年 / 118卷 / 01期
关键词
D O I
10.1115/1.2817496
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Experimental data on dividing steam-water two-phase annular flow in T-junctions with horizontal inlet and downwardly inclined branches were obtained The experiments were performed under experimental conditions which have not been examined before. The branch orientation was found to be a significant parameter affecting phase redistribution in the junction. Increasing the downward inclination of the branch was found to reduce the degree of phase separation in the junction under the present test conditions. This is caused by the nonuniform distribution of the liquid film thickness associated with the horizontal inlet annular flow. The phase redistribution data were compared with available models. The need for additional modelling studies was evident. The pressure changes of two-phase flow in the junction were closely correlated with the phase redistribution phenomenon. The data on pressure changes ill the junction were correlated ruins simple models based on momentum and mechanical energy balances.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 22 条
[21]  
SABA N, 1984, INT J MULTIPHAS FLOW, V10, P1, DOI 10.1016/0301-9322(83)90057-5
[22]   2-PHASE FLOW IN A T-JUNCTION WITH A HORIZONTAL INLET .1. PHASE-SEPARATION [J].
SEEGER, W ;
REIMANN, J ;
MULLER, U .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1986, 12 (04) :575-585