Posterior pelvic ring bone density with implications for percutaneous screw fixation

被引:10
作者
Eastman, Jonathan G. [1 ]
Shelton, Trevor J. [1 ]
Routt, Milton Lee Chip, Jr. [2 ]
Adams, Mark R. [3 ]
机构
[1] Calif Univ Sacramento, Dept Orthopaed Surg, Davis Med Ctr, 4860 Y St,Suite 3800, Sacramento, CA 95817 USA
[2] Univ Texas Hlth Sci Ctr Houston, 6414 Fannin St,Suite G 150, Houston, TX 77030 USA
[3] Rutgers New Jersey Med Sch, Dept Orthopaed, 140 Bergen St Level, Newark, NJ 07021 USA
关键词
S3; Third sacral segment; Posterior pelvic ring bone density; Iliosacral; Transsacral; ILIOSACRAL SCREWS; CLOSED REDUCTION; SACRAL FRACTURES; UNSTABLE PELVIS; PLACEMENT; QUANTIFICATION; STABILIZATION; ACCURATE;
D O I
10.1007/s00590-020-02782-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundAlthough the second (S2) and third (S3) sacral segments have been established as potential osseous fixation pathways for screw fixation, the S2 body has been demonstrated to have inferior bone density when compared to the body of the first (S1) sacral segment. Caution regarding the use of iliosacral screws at this level has been advised as a result. As transiliac-transsacral screws traverse the lateral cortices of the posterior pelvis, they may be relying on bone with superior density for purchase, which could obviate this concern. The objective of this study was to compare the bone density of the posterior ilium and sacroiliac joint to that of the sacral body at the first (S1), second (S2), and third (S3) sacral levels.Materials and methodsA retrospective case series was performed, reviewing the CT scans of 100 patients without prior pelvic trauma. Each CT was confirmed to have available osseous fixation pathways at the first (S1), second (S2), and third (S3) sacral segments. The bone density of the posterior ilium/sacroiliac joint (PISJ) and sacral body (SB) was measured using the embedded standardized Hounsfield units (HU) tool at each sacral level.ResultsThe average S2 PISJ bone density (320.1) was significantly higher than the S1 (286.5) and S3 (278.9) PISJ (p<0.0001) and S1 and S3 PISJ was not statistically different. The S1 sacral body bone density (231.1) was significantly higher than the S2 (182.1) and S3 (126.8) bone density (p<0.0001). The PISJ bone density is greater than the sacral body at every sacral level (p<0.0001).ConclusionThe S2 PISJ bone density is significantly greater than S1. The S1, S2, and S3 PISJ bone density is greater than the sacral body at all sacral levels, and the S1 body has higher bone density than the S2 and S3 bodies. These differences in bone density may have implications for the stability of posterior pelvic ring fixation constructs with regard to screw purchase.Level of evidenceLevel III-Case cohort series.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
[21]   Percutaneous removal of sacroiliac screw following iatrogenic neurologic injury in posterior pelvic ring injury: A case report [J].
Alkhateeb, Jawaher Mohammed ;
Chelli, Sabrina Saphia ;
Aljawder, Abdulla Anwar .
INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2020, 66 :416-420
[22]   In-screw cement augmentation for iliosacral screw fixation in posterior ring pathologies with insufficient bone stock [J].
Konig, M. A. ;
Hediger, S. ;
Schmitt, J. W. ;
Jentzsch, T. ;
Sprengel, K. ;
Werner, C. M. L. .
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2018, 44 (02) :203-210
[23]   Trans-sacral screw fixation of posterior pelvic ring injuries: review and expert opinion [J].
Ziran, Navid ;
Collinge, Cory A. ;
Smith, Wade ;
Matta, Joel M. .
PATIENT SAFETY IN SURGERY, 2022, 16 (01)
[24]   Trans-sacral screw fixation of posterior pelvic ring injuries: review and expert opinion [J].
Navid Ziran ;
Cory A. Collinge ;
Wade Smith ;
Joel M. Matta .
Patient Safety in Surgery, 16
[25]   Biomechanical comparison of posterior pelvic ring fixation [J].
Yinger, K ;
Scalise, J ;
Olson, SA ;
Bay, BK ;
Finkemeier, CG .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (07) :481-487
[26]   Treatment of Unstable Posterior Pelvic Ring Injury with S2-Alar-Iliac Screw and S1 Pedicle Screw Fixation [J].
Zheng, Jianxiong ;
Xiang, Jie ;
Zheng, Jianping ;
Feng, Xiaoreng ;
Chen, Bin .
WORLD NEUROSURGERY, 2022, 158 :E1002-E1010
[27]   Treatment of posterior pelvic ring injuries with minimally invasive percutaneous plate osteosynthesis [J].
Tang Hao ;
Yang Changwei ;
Zhang Qiulin .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (05) :1435-1439
[28]   Useful Intraoperative Technique for Percutaneous Stabilization of Bilateral Posterior Pelvic Ring Injuries [J].
Eastman, Jonathan G. ;
Kuehn, Reilly J. ;
Routt, Milton L. Chip, Jr. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (05) :E191-E197
[29]   Transiliac-transsacral Screws: What is the Required Implant Length for Adequate Percutaneous Fixation of the Posterior Pelvic Ring? [J].
Comerlatto, Leonardo ;
Concatto, Natalia Henz ;
Crestani, Marcus Vinicius ;
Silva, Taua Brum ;
Galia, Carlos Roberto ;
Teloken, Marco Aurelio .
REVISTA BRASILEIRA DE ORTOPEDIA, 2025, 60 (01) :1-9
[30]   Robot-assisted versus conventional percutaneous sacroiliac screw fixation for posterior pelvic ring injuries: a systematic review and meta-analysis [J].
Al-Naseem, Abdulrahman ;
Sallam, Abdelrahman ;
Gonnah, Ahmed ;
Masoud, Omar ;
Abd-El-Barr, Muhammad M. ;
Aleem, Ilyas S. .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (01) :9-20