Results of the introduction of an automated external defibrillation programme for non-medical personnel in Galicia

被引:3
|
作者
Lobatón, CR [1 ]
Mariño, JVP [1 ]
Antonio, J [1 ]
Vázquez, I [1 ]
Dolores, M [1 ]
Rodríguez, M [1 ]
机构
[1] Hosp Psiquiatr Conxo, Fdn Publ Urxencias Sanitarias Galicia 061, PEHF 061, Santiago De Compostela 15706, Spain
关键词
automated external defibrillation (AED); out-of-hospital cardiac arrest (OHCA); basic life support (BLS); emergency medical technician (EMT);
D O I
10.1016/S0300-9572(03)00153-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To describe the plan and development of a programme for the introduction of automated external defibrillation for non medical personnel and to report the results of the first 10 months of activity in a community which is predominently rural, such as Galicia. Methods: The plan for introduction of the project included aspects of logistics, training and control. We studied cardiac arrests, that were treated in basic life support ambulances (BLS-A) equipped with automated external defibrillators (AEDs), from 1st March to 31st December 2001. Results: Our community benefits from pioneering legislation in Spain. During the 10 months of study, 28 AEDs were in service, mostly in urban areas. In all cases, a thorough control of the quality of the service in which AEDs was used was carried out. 12% of the patients, who were victims of sudden cardiac death (SCD) and were found in ventricular fibrillation (VF), survived and were discharged from hospital. However, the percentage of patients found in VF is only around 26%. This is due to long assistance intervals (from the call to the arrival on site), and an important delay from the moment when circulatory collapse takes place until the emergency service 061 is called, more than 5 min in half the cases. Conclusions: The programme followed for the introduction of AEDs in Galicia was adapted to the socio-demographic characteristics of the population. The prehospital emergency assistance model was developed, executed and controlled by the Public Emergency Health Foundation of Galicia 061 (PEHF-061). The overall results of our first 10 months experience with the automated external defibrillation programme were as to be expected. In general, they are comparable to other published reports; however, ways of shortening the times from the point of collapse to defibrillation must be found, mainly by training the population and through the extension of automated external defibrillation provision to other first responders. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 50 条
  • [1] Introduction to the topic: The delegation of medical services to non-medical personnel
    Conzen, P.
    Peter, K.
    Larsen, R.
    ANAESTHESIST, 2007, 56 (04): : 311 - 311
  • [2] Semiautomatic external defibrillation plan for Galicia: results of implementation
    Iglesias Vazquez, Jose Antonio
    Rodriguez Nunez, Antonio
    Barreiro Diaz, Maria Victoria
    Sanchez Santos, Luis
    Cegarra Garcia, Maria
    Penas Penas, Monica
    EMERGENCIAS, 2009, 21 (02): : 99 - 104
  • [3] COMPARISON OF RESULTS FROM A CARDIAC AMBULANCE MANNED BY MEDICAL OR NON-MEDICAL PERSONNEL
    HAMPTON, JR
    DOWLING, M
    NICHOLAS, C
    LANCET, 1977, 1 (8010): : 526 - 529
  • [4] Medical and non-medical personnel in public health
    F Houghton
    Irish Journal of Medical Science, 2003, 172 : 154 - 154
  • [5] Delegation of medical responsibilities to non-medical personnel
    Ulsenheimer, K.
    ANAESTHESIST, 2009, 58 (05): : 453 - 458
  • [6] Medical and non-medical personnel in public health
    Houghton, F
    IRISH JOURNAL OF MEDICAL SCIENCE, 2003, 172 (03) : 154 - 154
  • [7] Analgesia by non-medical emergency personnel
    Lechleuthner, A.
    Neupert, M.
    NOTFALL & RETTUNGSMEDIZIN, 2017, 20 (05): : 433 - 438
  • [8] Development of an automated external defibrillation program in the autonomous community of Galicia (Spain)
    Iglesias-Vazquez, A.
    Cegarra-Garcia, M.
    Barreiro-Diaz, M., V
    Varela-Portas, J., Sr.
    Chay, N-Zas M. L.
    Mendez-Casares, J. M.
    Rodriguez-Nunez, A.
    Sanchez-Santos, L.
    ANNALS OF EMERGENCY MEDICINE, 2008, 51 (04) : 539 - 540
  • [9] The use of automated external defibrillators by non-medical first responders in Finland
    Harve, Heini
    Silfvast, Tom
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2004, 11 (03) : 130 - 133
  • [10] Non-medical GP programme directors
    Carr, Graham
    Milburn, Peter
    Atherley, Siobhan
    Arnott, Jane
    Terry, Louise
    EDUCATION FOR PRIMARY CARE, 2013, 24 (02) : 87 - 89