Fractal analysis of retinal microvasculature and coronary heart disease mortality

被引:118
作者
Liew, Gerald [1 ,2 ]
Mitchell, Paul [1 ]
Rochtchina, Elena [1 ]
Wong, Tien Yin [2 ,3 ]
Hsu, Wynne [4 ]
Lee, Mong Li [4 ]
Wainwright, Alan [1 ]
Wang, Jie Jin [1 ,2 ]
机构
[1] Univ Sydney, Dept Ophthalmol, Ctr Vis Res, Sydney, NSW 2006, Australia
[2] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore Eye Res Inst, Singapore 117595, Singapore
[4] Natl Univ Singapore, Sch Comp, Singapore 117548, Singapore
基金
英国医学研究理事会;
关键词
Microcirculation; Coronary heart disease; Mortality; Fractals; Retinal microcirculation; Blue Mountains Eye Study; DIABETIC-RETINOPATHY; VASCULAR CALIBER; VESSEL DIAMETER; IMAGE-ANALYSIS; COST; RISK; TREE; METAANALYSIS; GEOMETRY; DEATH;
D O I
10.1093/eurheartj/ehq431
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Fractal analysis provides a global assessment of vascular network architecture. We examined the relationship of retinal vascular fractal dimension (D-f) with coronary heart disease (CHD) mortality. Methods and results We examined the relationship of D-f with 14-year CHD mortality in a prospective, population-based cohort of 3303 participants aged 49 years or older. D-f was measured from digitized fundus photographs using computer-automated methods; CHD mortality was documented from Australian National Death Index records. Mean D-f in this population was 1.441 (standard deviation, 0.024). Over 14 years, there were 468 (14.2%) CHD deaths. Participants with suboptimal D-f (lowest and highest quartiles) had 50% higher 14-year CHD mortality than those with optimal D-f (middle quartiles), after adjusting for age, blood pressure, and other risk factors. Among participants aged <= 70 years, suboptimal D-f was associated with a nearly two-fold higher risk of CHD mortality [adjusted hazard ratio (HR) 1.89, 95% confidence interval (CI), 1.25, 2.84 for the lowest quartile and HR 1.87, CI 1.30, 2.69 for the highest quartile, compared with middle quartiles]. Conclusions D-f is a novel means of quantifying microvascular branching that independently predicted 14-year CHD mortality. These findings suggest that suboptimal microvascular branching may play a role in development of clinical cardiovascular disease.
引用
收藏
页码:422 / 429
页数:8
相关论文
共 50 条
  • [1] [Anonymous], 1991, LANCET, V338, P1425
  • [2] Boxt L M, 1994, J Thorac Imaging, V9, P8, DOI 10.1097/00005382-199424000-00002
  • [3] Medical progress - Coronary microvascular dysfunction
    Camici, Paolo G.
    Crea, Filippo
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (08) : 830 - 840
  • [4] Modeling the large-scale geometry of human coronary arteries
    Changizi, MA
    Cherniak, C
    [J]. CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2000, 78 (08) : 603 - 611
  • [5] Chapman N, 2002, CLIN SCI, V103, P111
  • [6] Quantitative Assessment of Early Diabetic Retinopathy Using Fractal Analysis
    Cheung, Ning
    Donaghue, Kim C.
    Liew, Gerald
    Rogers, Sophie L.
    Wang, Jie Jin
    Lim, Shueh-Wen
    Jenkins, Alicia J.
    Hsu, Wynne
    Lee, Mong Li
    Wong, Tien Y.
    [J]. DIABETES CARE, 2009, 32 (01) : 106 - 110
  • [7] Retinal arteriolar narrowing and left ventricular remodeling - The multi-ethnic study of atherosclerosis
    Cheung, Ning
    Bluemke, David A.
    Klein, Ronald
    Sharrett, A. Richey
    Islam, F. M. Amirul
    Cotch, Mary Frances
    Klein, Barbara E. K.
    Criqui, Michael H.
    Wong, Tien Yin
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) : 48 - 55
  • [8] Retinal Fractals and Acute Lacunar Stroke
    Cheung, Ning
    Liew, Gerald
    Lindley, Richard I.
    Liu, Erica Y.
    Wang, Jie Jin
    Hand, Peter
    Baker, Michelle
    Mitchell, Paul
    Wong, Tien Y.
    [J]. ANNALS OF NEUROLOGY, 2010, 68 (01) : 107 - 111
  • [9] CHARACTERIZATION OF THE NEOVASCULARIZATION PROCESS IN DIABETIC-RETINOPATHY BY MEANS OF FRACTAL GEOMETRY - DIAGNOSTIC IMPLICATIONS
    DAXER, A
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (12) : 681 - 686
  • [10] DILEVA A, 2010, MICROVASC RES, V80, P267