Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia

被引:147
作者
Hans, P [1 ]
Dewandre, PY [1 ]
Brichant, JF [1 ]
Bonhomme, V [1 ]
机构
[1] CHR Citadelle, Univ Dept Anaesthesia & Intens Care Med, Liege, Belgium
关键词
anaesthetics i.v; ketamine; monitoring; Bispectral Index; spectral entropy;
D O I
10.1093/bja/aei047
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The Bispectral Index (BIS) and spectral entropy of the electroencephalogram can be used to assess the depth of hypnosis. Ketamine is known to increase BIS in anaesthetized patients and may confound that index as a guide to steer administration of hypnotics. We compared the effects of ketamine on BIS, response entropy (RE) and state entropy (SE) during surgery under sevoflurane anaesthesia. Methods. Twenty-two women undergoing gynaecological surgery were enrolled in this double-blind, randomized study. Anaesthesia was induced i.v. and maintained with sevoflurane. Under stable surgical and anaesthetic conditions, patients were assigned to receive either a bolus of ketamine 0.5 mg kg(-1) or the same volume of saline. Blood pressure, heart rate, BIS, RE and SE were measured every 2.5 min from 10 min before (baseline) until 15 min after ketamine or saline administration. The maximum relative increase in BIS, RE and SE compared with baseline was calculated for each patient. Values are mean (sd). Results. Baseline values were BIS 33 (4), RE 31 (5), SE 30 (5) for the ketamine patients and BIS 35 (3), RE 33 (5) and SE 32 (6) for the patients receiving saline. BIS, RE and SE increased significantly from 5 min (BIS) and 2.5 min (RE and SE) after ketamine administration, peaking at 46 (8) (BIS), 52 (12) (RE) and 50 (12) (SE) respectively. The maximum relative increase in RE [42.2 (10.4%)] and SE [41.6 (10.9)%] was higher than that of BIS [29.4 (10.4%)]. Blood pressure, heart rate and RE-SE gradient did not change in either group. Conclusions. Ketamine administered under sevoflurane anaesthesia causes a significant increase in BIS, RE and SE without modification of the RE-SE gradient. This increase is paradoxical in that it is associated with a deepening level of hypnosis.
引用
收藏
页码:336 / 340
页数:5
相关论文
共 24 条
  • [21] Time-frequency balanced spectral entropy as a measure of anesthetic drug effect in central nervous system during sevoflurane, propofol, and thiopental anesthesia
    Vakkuri, A
    Yli-Hankala, A
    Talja, P
    Mustola, S
    Tolvanen-Laakso, H
    Sampson, T
    Viertiö-Oja, H
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (02) : 145 - 153
  • [22] Spectral entropy as an electroennopbalograpbic measure of anesthetic drug effect - A comparison with bispectral index and precessed midlatency auditory evoked response
    Vanluchene, ALG
    Vereecke, H
    Thas, O
    Mortier, EP
    Shafer, SL
    Struys, MMRF
    [J]. ANESTHESIOLOGY, 2004, 101 (01) : 34 - 42
  • [23] A comparison of bispectral index and ARX-derived auditory evoked potential index in measuring the clinical interaction between ketamine and propofol anaesthesia
    Vereecke, HEM
    Struys, MMRF
    Mortier, EP
    [J]. ANAESTHESIA, 2003, 58 (10) : 957 - 961
  • [24] Overestimation of bispectral index in sedated intensive care unit patients revealed by administration of muscle relaxant
    Vivien, B
    Di Maria, S
    Ouattara, A
    Langeron, O
    Coriat, P
    Riou, B
    [J]. ANESTHESIOLOGY, 2003, 99 (01) : 9 - 17