Method for geometric distortion correction in fMRI based on three echo planar phase images

被引:3
作者
Valkovic, L. [1 ]
Windischberger, C. [2 ,3 ]
机构
[1] Slovak Acad Sci, Inst Measurement Sci, Bratislava 84104, Slovakia
[2] Med Univ Vienna, MR Ctr Excellence, A-1090 Vienna, Austria
[3] Med Univ Vienna, Ctr Biomed Engn & Phys, A-1090 Vienna, Austria
来源
MEASUREMENT SCIENCE REVIEW | 2010年 / 10卷 / 04期
关键词
Field map; distortion correction; fMRI; FIELD; INHOMOGENEITY;
D O I
10.2478/v10048-010-0022-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Functional magnetic resonance imaging (fMRI) is a quickly developing method for non-invasive dynamic brain studies. It uses swift acquisition sequences like echo planar imaging (EPI) that are very sensitive to susceptibility artifacts. These artifacts relate to magnetic field inhomogeneities and may cause geometric distortions. Many methods for correcting these distortions are currently used. Most common are the field mapping methods that use the map of field strength. To create a field map, different approaches can be used and different data must be acquired for each method. This paper compares a commonly used conventional gradient echo (GE) field mapping method with a 3EPI phase images based method. Although the EPI method is more sophisticated and was expected to perform better, the GE field maps showed better results in distortion correction. The cause of this is not in the method's principle itself, but in its high requirements.
引用
收藏
页码:116 / 119
页数:4
相关论文
共 12 条
  • [1] [Anonymous], THESIS U NOTTINGHAM
  • [2] [Anonymous], SPM STAT PARAMETRIC
  • [3] Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging
    Holland, Dominic
    Kuperman, Joshua M.
    Dale, Anders M.
    [J]. NEUROIMAGE, 2010, 50 (01) : 175 - 183
  • [4] Huettel S. A., 2009, Functional Magnetic Resonance Imaging, V2nd
  • [5] Jezzard P, 1999, HUM BRAIN MAPP, V8, P80, DOI 10.1002/(SICI)1097-0193(1999)8:2/3<80::AID-HBM2>3.0.CO
  • [6] 2-C
  • [7] CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS
    JEZZARD, P
    BALABAN, RS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) : 65 - 73
  • [8] Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity
    Kadah, YM
    Hu, XP
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) : 362 - 370
  • [9] Mapping of magnetic field inhomogeneity and removal of its artifact from MR images
    Moghaddam, AN
    Soltanian-Zadeh, H
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 780 - 787
  • [10] Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps
    Reber, PJ
    Wong, EC
    Buxton, RB
    Frank, LR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 328 - 330