ASSOCIATIONS BETWEEN MATERIALS USED AND WORK-RELATED MUSCULOSKELETAL HAND COMPLAINTS AMONG HAEMODIALYSIS NURSES

被引:4
作者
Westergren, Eva [1 ]
Ludvigsen, Mette Spliid [2 ,3 ]
Lindberg, Magnus [1 ,4 ]
机构
[1] Univ Gavle, Dept Caring Sci, Fac Hlth & Occupat Studies, Gavle, Sweden
[2] Aarhus Univ, Fac Nursing & Hlth Sci, Dept Clin Med, Randers Reg Hosp, Aarhus, Denmark
[3] Nord Univ, Bodo, Norway
[4] Uppsala Univ, Dept Publ Hlth & Caring Sci, Uppsala, Sweden
关键词
Ergonomics; Haemodialysis; Work-related musculoskeletal disorders; STRAIN INDEX; HEALTH-CARE; STRESS; DISORDERS; BURNOUT; DIALYSIS; RISK; PAIN;
D O I
10.1111/jorc.12317
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background One in every two haemodialysis nurses has reported musculoskeletal complaints concerning their hands, which is twice that reported for hospital nurses in general. It is possible that there is an association between the materials used by haemodialysis nurses and the occurrence of hand complaints. Objectives To examine the association between the type of dialysis machine and disposables used with the occurrence of hand complaints among haemodialysis nurses. To compare occupational risks of developing work-related musculoskeletal disorders based on the materials used for haemodialysis. Design Cross-sectional. Participants Two hundred and eighty-two nurses working in 27 haemodialysis centres in Sweden participated in a survey, and 19 nurses at five centres were observed during priming procedures. Measurements Nurses supplied demographic data and answered the Nordic Musculoskeletal Questionnaire. Centre level data regarding machines and disposables used for haemodialysis during the past year were also collected. Results There were no differences in the prevalence of hand complaints based on the type of haemodialysis machines, dialysers or tubing used. There were no differences found in physical exposure to the hands during priming, based on machine type used. Conclusion The results of this study could not reveal any association between disposable materials used and the occurrence of hand complaints among haemodialysis nurses. Additionally, there were no occupational risks detected based on the types of machines used. Hence, the results of the present study strongly indicate that a deeper ergonomic analysis of the work environment is needed to understand the prevalence of hand complaints among nurses working in haemodialysis settings.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 31 条
  • [1] [Anonymous], 2016, NURSING RES GENERATI
  • [2] Response rate differences between web and alternative data collection methods for public health research: a systematic review of the literature
    Blumenberg, Cauane
    Barros, Aluisio J. D.
    [J]. INTERNATIONAL JOURNAL OF PUBLIC HEALTH, 2018, 63 (06) : 765 - 773
  • [3] PSYCHOLOGICAL STRESS AND STRAIN IN DIALYSIS STAFF-A SYSTEMATIC REVIEW
    Boehmert, Maren
    Kuhnert, Saskia
    Nienhaus, Albert
    [J]. JOURNAL OF RENAL CARE, 2011, 37 (04) : 178 - 189
  • [4] Corner Brian, 2019, Can Oncol Nurs J, V29, P58
  • [5] Prevalence of Musculoskeletal Disorders for Nurses in Hospitals, Long-Term Care Facilities, and Home Health Care: A Comprehensive Review
    Davis, Kermit G.
    Kotowski, Susan E.
    [J]. HUMAN FACTORS, 2015, 57 (05) : 754 - 792
  • [6] de Kleijn R, 2017, J RENAL CARE, V43, P98, DOI 10.1111/jorc.12193
  • [7] NURSE STRESS IN HOSPITAL AND SATELLITE HAEMODIALYSIS UNITS
    Dermody, Kirsten
    Bennett, Paul N.
    [J]. JOURNAL OF RENAL CARE, 2008, 34 (01) : 28 - 32
  • [8] Work related risk factors for musculoskeletal complaints in the nursing profession: Results of a questionnaire survey
    Engels, JA
    vanderGulden, JWJ
    Senden, TF
    vantHof, B
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1996, 53 (09) : 636 - 641
  • [9] European Agency for Safety and Health at Work, 2009, OSH in figures: stress at work - facts and figures, DOI [10.2802/10952, DOI 10.2802/10952]
  • [10] The Revised Strain Index: an improved upper extremity exposure assessment model
    Garg, Arun
    Moore, J. Steven
    Kapellusch, Jay M.
    [J]. ERGONOMICS, 2017, 60 (07) : 912 - 922