Energy Production Analysis of Photovoltaic Shading Devices (PVSD) in Integrated Facade Systems (IFS)

被引:4
作者
Ibraheem, Yahya [1 ]
Piroozfar, Poorang [2 ,3 ]
Farr, Eric R. P. [3 ,4 ]
Ravenscroft, Neil [5 ]
机构
[1] Univ Technol Iraq, Dept Architectural Engn, Baghdad, Iraq
[2] Univ Brighton, Sch Environm & Technol, Brighton, England
[3] NONAMES Design Res & Studies, San Diego, CA USA
[4] NewSch Architecture & Design, Digital Architecture & Fabricat Program, San Diego, CA USA
[5] Royal Agr Univ, Sch Real Estate & Land Management, Cirencester, England
关键词
sensitivity analysis; base-case model; benchmarking; building energy simulation (BES); energy production; fully-glazed facades; highly-glazed facades; office buildings;
D O I
10.3389/fbuil.2020.00081
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The need for more responsive built environment in the age of climate change has led building professionals to resort to integrated design solutions where a combination of different technologies is utilized to improve what traditionally the tectonics of a building were expected to fulfill rather independently. One of such solutions are Integrated Facade Systems (IFS), which deploy different technologies in or related to building facades to improve building performance. To measure the efficiency of such solutions, three broad categories of methods are in use, namely real, scaled or mock physical models, mathematical models and simulations of which the latter is the most time- and cost-efficient and depending on the platform can provide the most user-friendly method. The flexibility, ease of use and broader coverage of Building Energy Simulation (BES) tools make them a more viable alternative. Developing a benchmark or a base-case model against which the impact of parametric changes of the IFS can be measured is the first step in BES and bares high importance on methodological reliability and validity of the results. This paper uses a specially devised methodology to develop a base-case model for BES of highly- to fully-glazed office buildings in hot and arid climates. BES results of the energy production of the base-case and over 1,600 parametric combinations of the model's system and sub-system levels variables have been used to perform a sensitivity analysis to test the robustness of the results. The results presented in this paper form the last phase of a three-phased analysis of a comprehensive research, designed to provide a full account of how different combinations of a set of variables can and will influence energy performance of highly- to fully-glazed office buildings in hot and arid climates.
引用
收藏
页数:12
相关论文
共 57 条
[1]  
Al-Helal A, 2015, INT J INVENTIVE ENG, V3, P11
[2]  
Anderson Kjell., 2014, Design Energy Simulation for Architects: Guide to 3D Graphics
[3]   A performance comparison of sensitivity analysis methods for building energy models [J].
Anh-Tuan Nguyen ;
Reiter, Sigrid .
BUILDING SIMULATION, 2015, 8 (06) :651-664
[4]  
Attia S., 2009, P 11 INT BUILDING PE
[5]  
Attia S., 2010, BUILDING PERFORMANCE
[6]  
Awadh O., 2013, SUSTAINABLE BUILDING
[7]  
Ayyad T. M., 2011, THESIS BRIT U DUBAI
[8]  
Azhar S., 2009, P 45 ASC ANN C
[9]   A PV installation framework concerning electricity variable rates [J].
Bahr, Wassim .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2018, 39 (08) :802-812
[10]  